Permit Information
Permit NumberBLD15-01919
StatusFinaled
Name THE RUSSELL CORPORATION
Site Address 515 W IDAHO ST
Project NamePaulsen Bldg Rehabilitation
Customer Number 
ePlanReviewYes
Description
(FIVE ONE FIVE - PAULSEN BUILDING) (12-22-15 PLAN MODIFICATION TO PROVIDE A SLOPED FLOOR TRANSITION AT THE 2ND STORY, REMOVE THE WEST INTERIOR BASEMENT STAIRWAY, AND TO SHIFT THE MEN’S RESTROOM ON THE 1ST STORY.) The fire sprinkler system is used for story increase and to allow an A-2 Occupancy fire area on the 2nd story. An NFPA 13 fire sprinkler system will be installed in conjunction with this permit. To convert an existing building to a dance hall/studio. Food and beverages shall not be served within this building under this permit. This building has a 1,668 square foot basement used for storage, a 1,717 square foot first story that may be used for food and beverage consumption in the future under a separate permit, and a 1,642 square foot second story used as a dance hall/studio. This building has a total floor area of about 3,359 square feet (about 5,027 square feet including the basement). Work is to include 2 restrooms accessible to the disabled, a new interior landing at the West Idaho Street main entrance door, reconfigured top treads and risers of an existing interior stairway at the 2nd story, and a performance area on the 2nd story. Structural work includes new steel beams to support the interior masonry wall located above a new wall opening on the 2nd story, new steel columns to support the new beams and to transfer the gravity load to the basement, and new concrete footings in the basement to support the new steel columns. Special Inspection is required for soils, welding, concrete, and post installed concrete anchors (e.g. epoxy anchors). Structural Observation by the Engineer of Record is required for bolting the new channel beams and columns through the existing masonry walls. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 9/22/20169/16/2016 DONE
This permit finaled on the web by Leonard Butler
First Notice 9/3/20169/12/2016 DONE
Mailed 9-13-16
BLD-Final8/23/20168/24/20168/24/2016APASS
DetailsDave Hannah
Call me when you head my way. I''m not on site. Phone #: ###-#### Inspection requested via web by Bob Thornton
Print Occupancy Form  8/24/2016 DONE
Permanent Occupancy  8/24/2016 DONE
BLD-Final8/19/20168/22/20168/23/2016PNR
DetailsDave Hannah
Please call 20 minutes before you arrive. I''m not on site. Phone #: ###-#### Inspection requested via web by Bob Thornton
Zoning Approval8/22/20168/22/20168/22/2016 PASS
DetailsTed Vanegas
BLD-Final8/18/20168/19/20168/19/2016PCANC
DetailsMike Jordan
Please give me a call 20 minutes before you plan to be there. I''m not on site. Phone #: ###-#### >> Inspection requested via web by Bob Thornton Inspection cancelled from web by: Bob Thornton
FIRE-Final Inspection8/18/20168/18/20168/18/2016APASS
DetailsJim Page
Fire sprinkler inspection complete, fire alarm inspection complete, fire extinguishers are in place with current inspection tags. Final life fire safety inspection passed/complete.
BLD-Wall cover4/6/20164/7/20164/7/2016APASS
DetailsDave Hannah
Please call when your are on your way Phone #: ###-#### Inspection requested via web by Bob Thornton
CHANGE STATUS TO (ISS)  2/23/2016 DONE
(F) Reprint permit  2/23/2016 DONE
OVERRIDE  12/22/2015  
Routing - PLAN CHECK12/21/2015 12/22/2015 PASS
DetailsCarl Westfall
Plan mod approved
PLANS/APPL TAKEN TO FRONT DESK  12/22/2015 DONE
Permit Ready to Issue  12/22/2015 DONE
DetailsChristina Prado
Plan mod ready to issue, hourly fees attached

DO NOT RE-ISSUE, CHANGE STATUS ONLY
Plan assigned to (CJW)12/3/2015 12/22/2015 PASS
DetailsCarl Westfall
(1st done) Paulsen building plan mod
Plan resubmittals received  12/21/2015 DONE
BLD-Footing12/14/201512/14/201512/14/2015PPASS
DetailsDave Hannah
Bob Phone #: ###-####
Routing - PLAN CHECK12/9/2015 12/11/2015 FAIL
DetailsCarl Westfall
Exit separation issues
Plan resubmittals requested  12/11/2015 DONE
Plan Modification Accepted  12/9/2015 DONE
Workflow received in ePlanReview
Plan Modification Accepted  12/3/2015 DONE
DetailsChristina Prado
Per request from David Ruby & Carl Westfall - PLan Modification for minor changes to the floor plan, including men's room & prep resizing, misc door reloaction, etc.
Issue PAID IN FULL permit  11/17/2015 DONE
Print Occupancy Form  11/17/2015 DONE
Expiration Notice11/9/201512/2/201511/9/2015 DONE
DetailsBrittany Hill
OVERRIDE  6/29/2015  
Plan assigned to (CJW)6/9/20156/9/20156/29/2015 PASS
DetailsCarl Westfall
PAULSEN BUILDING (June 25 - 15 days) Level 3 TI - ePlanReview
PLANS/APPL TAKEN TO FRONT DESK  6/29/2015 DONE
Permit Ready to Issue  6/29/2015 DONE
***ALL REQUIRMENTS MET 11-17-15 //CEV NEEDS RP ONLY 11-17-15 //CEV Needs; G.C. form, revised certificate of value, responsible person, ACHD
Routing - PLAN CHECK6/25/2015 6/26/2015 PASS
DetailsCarl Westfall
Completed the 2nd IBC review
Routing PW Sewer Rating6/26/2015 6/26/2015 PASS
DetailsJennifer Bruner
Changing a Tub for a Service sink
Plan resubmittals received  6/25/2015 DONE
1st review completed  6/25/2015 DONE
Plan resubmittals requested  6/25/2015 DONE
Routing - PLAN CHECK6/9/2015 6/25/2015 FAIL
DetailsCarl Westfall
Revised drawings required
Routing - FIRE6/9/20156/9/20156/12/2015 PASS
DetailsScott Arellano
Comments attached to plans
Routing - PLUMBING6/9/2015 6/10/2015 PASS
DetailsBill VanDegrift
Per plan and ISPC.
Routing - Design Review6/9/2015 6/10/2015 PASS
DetailsMatthew A Halitsky
Matt Halitsky - DRH15-00187
Routing - Addressing6/9/2015 6/9/2015 PASS
DetailsEmily Dixon
Routing - PUBLIC WORKS6/9/2015 6/9/2015 PASS
DetailsEmily Dixon
Routing - Erosion and Sediment6/9/2015 6/9/2015 PASS
DetailsEvan Jenkins
(PAULSEN BLDG) Remodel changing occupancy from mercantile to an assembly use per approved plans. Will be wanting a certificate of occupancy for dance studio as part of this permit. REHABILITATION AND ADAPTIVE REUSE OF THE HISTORIC PAULSEN BUILDING IN DOWNTOWN BOISE. PROJECT INCLUDES SELECTIVE INTERIOR DEMOLITION, NEW MEN'S AND WOMEN'S RESTROOMS, AND RELATED NEW MECHANICAL, ELECTRICAL AND PLUMBING WORK.
Plan Reviewer's activity  6/9/2015 DONE
DetailsJason Blais
Emailed architect to have him contact ACHD for evaluation of any impact fees due. Written verification to be provided to our Permit Counter prior to the building permit being issued.
Routing PW Sewer Rating6/9/2015 6/9/2015 PASS
DetailsJennifer Bruner
Pending Assignment by JCB6/9/2015 6/9/2015 DONE
DetailsJason Blais
Application received  6/5/2015 DONE
Application submitted via PDS Online on Jun 5 2015 2:29PM
Intake Approval  6/5/2015 PASS
DetailsJason Blais
Prescreen approved by Adele Schaffeld-Griffin and plan review fees paid.