BLD-Final | 7/28/2016 | 7/29/2016 | 7/29/2016 | A | PASS |
Jim Sly
|
|
|
Bob Phone #: ###-####
|
DOC - Permit Finaled | 7/29/2016 | 7/29/2016 | 7/29/2016 | P | PASS |
Jim Sly
|
|
|
|
PubWorks Occupancy Approval | 7/12/2016 | 7/12/2016 | 7/12/2016 | | DONE |
Jason C. Taylor
|
|
|
A letter from the applicant’s civil engineer indicating that the final grading and drainage is acceptable has been received by Public Works. Final occupancy may be approved by the building department. Jason Taylor ###-####.
|
BLD-Other | 1/20/2016 | 1/21/2016 | 1/21/2016 | A | PART |
Tony Young
|
|
|
Bob-- Fire soffit inspection Phone #: ###-####,, ok to start covering with fire treated t &g material
|
BLD-Other | 1/19/2016 | 1/20/2016 | 1/20/2016 | A | PART |
Tony Young
|
|
|
Bob-- Fire soffit inspection Phone #: ###-####,, material on site
|
BLD-Energy code compliance | 11/6/2015 | 11/6/2015 | 11/6/2015 | P | PASS |
Jim Storey
|
|
|
Bob Phone #: ###-####
|
BLD-Energy code compliance | 11/5/2015 | 11/5/2015 | 11/5/2015 | P | NR |
Tony Young
|
|
|
Bob Phone #: ###-####
|
BLD-Framing/Rough-in | 10/30/2015 | 11/2/2015 | 11/2/2015 | A | PART |
Tony Young
|
|
|
Bob Phone #: ###-####,, correction posted
|
BLD-Other | 10/28/2015 | 10/28/2015 | 10/28/2015 | P | PASS |
Tony Young
|
|
|
Bob Phone #: ###-####,, soffits ok
|
BLD-Wall Bracing | 10/27/2015 | 10/28/2015 | 10/28/2015 | A | PASS |
Tony Young
|
|
|
Bob Phone #: ###-####
|
Plan Modification Accepted | | | 10/12/2015 | | DONE |
|
|
|
new manual j report
|
Routing - MECHANICAL | 10/12/2015 | | 10/12/2015 | | PASS |
Troy James
|
|
|
New manual j report. Contractor to build room for second level furnace.
|
BLD-Wall Bracing | 10/6/2015 | 10/7/2015 | 10/7/2015 | A | PART |
Dave Hannah
|
|
|
Bob Phone #: ###-#### c/n on site missing holddowns ok to cover ext city plans marked up
|
BLD-Foundation | 8/7/2015 | 8/7/2015 | 8/7/2015 | P | PART |
Tony Young
|
|
|
Wall // Pat Phone #: ###-####,, work in progress
|
BLD-Footing | 8/6/2015 | 8/6/2015 | 8/6/2015 | P | PART |
Tony Young
|
|
|
Pat Phone #: ###-####,, work in progress
|
PubWorks Subgrade Approval | 8/5/2015 | 8/5/2015 | 8/5/2015 | | DONE |
Jason C. Taylor
|
|
|
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Jason Taylor ###-####.
|
Issue PAID IN FULL permit | | | 7/27/2015 | | DONE |
Christina Prado
|
|
|
|
Inspection Record Card- Bld | | | 7/27/2015 | | DONE |
Christina Prado
|
|
|
|
OVERRIDE | | | 7/23/2015 | | |
|
|
|
|
Plan assigned to (LEG) Tisha | 6/22/2015 | | 7/23/2015 | | DONE |
Tisha Gallop
|
|
|
1st review 7/20 L2 ePlan; pending hillside
(make sure subgrade insp scope is in)
|
Routing PW Grading-Hillside | 7/21/2015 | | 7/23/2015 | | PASS |
Jason C. Taylor
|
|
|
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at ###-####
Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at ###-####.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/23/2015 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 7/23/2015 | | DONE |
|
|
|
requirements met
|
Plan resubmittals received | | | 7/21/2015 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 7/21/2015 | | 7/21/2015 | | PASS |
Tisha Gallop
|
|
|
|
1st review completed | | | 7/20/2015 | | FAIL |
|
|
|
pending plan check and PW Grading-Hillside
|
Routing - PLAN CHECK | 6/22/2015 | | 7/20/2015 | | FAIL |
Tisha Gallop
|
|
|
|
Routing PW Grading-Hillside | | | 7/6/2015 | | FAIL |
|
|
|
I have reviewed the permit for the above mentioned address. Please have a Foundation Plan & Grading Plan sent over to your geotechnical engineer (Strata) to address the structure and the adjacent slopes. The columns on the rear (east) seem to be too close to the slope with the elevation given on the foundation plan. The grading plan needs to show the slope away from the structure on the south side as well. I think you may need a small retaining wall there. Also, the foundation plan is incorrect as it shows your columns going 30’ into the ground. I believe you need a well drilling permit for that type of excavation. Let me know if you have any questions.
|
Routing - MECHANICAL | | | 6/26/2015 | | PASS |
|
|
|
|
Routing - FIRE | 6/25/2015 | | 6/25/2015 | | PASS |
Scott Arellano
|
|
|
This home has been evaluated for Fire Department Vehicle access. Approved as shown.
|
Routing - PLANNING | | | 6/23/2015 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 6/22/2015 | | 6/23/2015 | | PASS |
Connie Baumgartner
|
|
|
|
Routing - Erosion and Sediment | 6/22/2015 | | 6/22/2015 | | PASS |
Evan Jenkins
|
|
|
(Site Prep Inspection and Approval Required prior to Any Earth Disturbance)
Permit for the construction of a new 5,133 sq. ft., two story (main level 3,880 sq. ft., lower level 1,253 sq. ft.) single family dwelling with 4 bedrooms, 6 and a half bathrooms, approximately 500 sq. ft. of covered patio/porch and a 1,200 sq. ft. attached garage
|
Routing - Addressing | 6/22/2015 | | 6/22/2015 | | PASS |
Emily Dixon
|
|
|
|
Intake Approval | | | 6/22/2015 | | PASS |
|
|
|
|
Intake Approval | | | 6/19/2015 | | FAIL |
|
|
|
NEED to have Erosion and Grading plans stamped by engineer.
|
Application received | | | 6/17/2015 | | DONE |
|
|
|
Application submitted via PDS Online on Jun 17 2015 2:39PM
|