BLD-Aging Inspection | 10/5/2018 | 10/5/2018 | 10/5/2018 | | PASS |
Jim Storey
|
|
|
Phone #: ###-#### Inspection requested via web by Raquel Kenley c/n latch broken west gate// must self close. latch to close to grade/ c/n not complet no calls for reinsp.
|
BLD-Final | 5/23/2018 | 5/24/2018 | 5/24/2018 | P | FAIL |
Jim Storey
|
|
|
Phone #: ###-#### Inspection requested via web by Raquel Kenley c/n latch broken west gate// must self close.
|
BLD-Aging Inspection | 1/28/2016 | 1/28/2016 | 1/29/2016 | | FAIL |
Jim Storey
|
|
|
ncfi
|
BLD-Aging Inspection | 1/27/2016 | 1/27/2016 | 1/27/2016 | | NR |
Jim Storey
|
|
|
ncfi
|
BLD-Foundation | 9/14/2015 | 9/15/2015 | 9/15/2015 | A | PASS |
Jim Storey
|
|
|
Berny-please call Berney as soon as poss-would like to make sure all is ok for the gunite shoot. PW approved the geot please see his notes in Tidemark Phone #: ###-####
|
OVERRIDE | | | 9/14/2015 | | |
|
|
|
|
PubWorks Subgrade Approval | 9/14/2015 | 9/14/2015 | 9/14/2015 | | DONE |
Jason C. Taylor
|
|
|
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Jason Taylor ###-####.
|
BLD-Foundation | 9/10/2015 | 9/11/2015 | 9/11/2015 | P | DEFR |
Jim Storey
|
|
|
Rebar pool // Bernie Phone #: ###-#### need pw aprovals then ok to place gunite.
|
Plan assigned to (JG) | 7/21/2015 | 7/21/2015 | 8/20/2015 | | PASS |
Javier Guzman
|
|
|
1st review completed, Pool
|
Routing - PLAN CHECK | 8/14/2015 | | 8/20/2015 | | PASS |
Javier Guzman
|
|
|
|
Routing - PLANNING | 8/14/2015 | | 8/20/2015 | | PASS |
Colleen T Carroll
|
|
|
|
Permit Ready to Issue | | | 8/20/2015 | | DONE |
Brittany Hill
|
|
|
|
Inspection Record Card- Bld | | | 8/20/2015 | | DONE |
Javier Guzman
|
|
|
|
Case Summary (BLD) | | | 8/20/2015 | | DONE |
Javier Guzman
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/20/2015 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 8/20/2015 | | DONE |
|
|
|
|
CHANGE STATUS TO (ISS) | | | 8/20/2015 | | DONE |
Brittany Hill
|
|
|
|
Routing PW Grading-Hillside | 8/14/2015 | | 8/18/2015 | | PASS |
Jason C. Taylor
|
|
|
A letter from the applicant’s geotechnical engineer indicating that the pool subgrade is acceptable must be approved by Public Works prior to scheduling inspections. If you have any questions call Jason Taylor ###-####.
|
Plan resubmittals received | | | 8/14/2015 | | DONE |
|
|
|
resubmittals recieved 2 struct engineering-took to JG
|
Routing Walk-In (BLD) | 7/15/2015 | 7/15/2015 | 7/15/2015 | A | FAIL |
Javier Guzman
|
|
|
Needs to show barrier locations, need engineering for hillside construction, need to pass Planning and Hillside
|
Routing Walk-In (Zoning) | 7/13/2015 | 7/13/2015 | 7/15/2015 | A | FAIL |
Javier Guzman
|
|
|
needs a site plan showing property lines
|
1st review completed | | | 7/15/2015 | | FAIL |
Javier Guzman
|
|
|
|
Routing Walk-In (PW Hillside) | 7/10/2015 | 7/10/2015 | 7/13/2015 | A | FAIL |
Jason C. Taylor
|
|
|
Need scaled site plan to determine location of pool from retaining wall. Jason Taylor ###-####.
|
Application received | | 7/9/2015 | | | |
|
|
|
|