BLD-Final | 4/13/2017 | 4/14/2017 | 4/14/2017 | A | PASS |
Jim Sly
|
|
|
would like call ahead; David Phone #: ###-####
|
DOC - Permit Finaled | 4/14/2017 | 4/14/2017 | 4/14/2017 | P | PASS |
Jim Sly
|
|
|
|
BLD-Final | 4/10/2017 | 4/11/2017 | 4/11/2017 | A | NR |
Jim Sly
|
|
|
David Phone #: ###-#### Need F/P final.
|
BLD-Conference | 1/13/2017 | 1/17/2017 | 1/17/2017 | P | CANC |
Jim Sly
|
|
|
|
BLD-Aging Inspection | 1/11/2017 | 1/11/2017 | 1/13/2017 | | CANC |
Jim Sly
|
|
|
|
BLD-Aging Inspection | 1/12/2017 | 1/12/2017 | 1/13/2017 | | CANC |
Jim Sly
|
|
|
|
BLD-Framing/Rough-in | 8/29/2016 | 8/30/2016 | 8/30/2016 | P | PASS |
Jim Sly
|
|
|
David Phone #: ###-####
|
BLD-Framing/Rough-in | 8/24/2016 | 8/26/2016 | 8/26/2016 | P | FAIL |
Mike Jordan
|
|
|
David Phone #: ###-####. Strap LVL at garage for portal frame. Strap double top plate splice i garage at either sides of opening to mudroom. Complete lateral bracing on T01, T03, T06, T08, trusses. Missed interior bearing points on 2 T02 trusses. Provide fix from truss engineer. Strap double top plates LVL in living room. Add additional stud to both ends of LVL in living room and nail or strap. Provide header at openong under T04 truss interior bearing point. Correction notice posted. Ok to insulate.
|
BLD-Framing/Rough-in | 7/25/2016 | 7/25/2016 | 7/25/2016 | P | PART |
Jim Sly
|
|
|
would like call ahead; Micheal Phone #: ###-#### Shear only.......OK
|
BLD-Aging Inspection | 3/17/2016 | 3/17/2016 | 3/17/2016 | | PEND |
Phil Shearer
|
|
|
|
BLD-Foundation | 11/3/2015 | 11/4/2015 | 11/4/2015 | A | PASS |
Phil Shearer
|
|
|
Greg Phone #: ###-####
|
BLD-Footing | 10/28/2015 | 10/28/2015 | 10/28/2015 | P | PASS |
Phil Shearer
|
|
|
Greg Phone #: ###-####
|
Inspection Record Card- Bld | | | 9/22/2015 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 9/22/2015 | | DONE |
|
|
|
|
OVERRIDE | | | 9/18/2015 | | |
|
|
|
|
Inspection Record Card- Bld | | | 9/18/2015 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 9/18/2015 | | DONE |
|
|
|
|
Telephone call | | | 9/18/2015 | | DONE |
|
|
|
Spoke with Dave informing him the permit is ready and the fee amount that is due
|
Case Summary (BLD) | | | 9/18/2015 | | DONE |
|
|
|
|
1st review completed | | | 9/18/2015 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 9/18/2015 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 9/18/2015 | | DONE |
|
|
|
All Requirements Met
|
Plan assigned to (LEG) Tisha | 9/4/2015 | | 9/18/2015 | | DONE |
Tisha Gallop
|
|
|
9/18
|
Routing - PLAN CHECK | 9/17/2015 | | 9/18/2015 | | PASS |
Tisha Gallop
|
|
|
|
Routing - MECHANICAL | 9/9/2015 | | 9/17/2015 | | PASS |
Troy James
|
|
|
|
Routing - PLANNING | 9/9/2015 | | 9/9/2015 | | PASS |
David Moser
|
|
|
|
Routing - PUBLIC WORKS | 9/8/2015 | | 9/9/2015 | | PASS |
Jennifer Bruner
|
|
|
|
Routing - Addressing | 9/4/2015 | | 9/8/2015 | | PASS |
Jason C. Taylor
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 9/4/2015 | | DONE |
Christina Prado
|
|
|
|
Intake Approval | | | 9/4/2015 | | PASS |
Christina Prado
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 9/4/2015 | | DONE |
Christina Prado
|
|
|
|
Application received | | 9/4/2015 | | | |
|
|
|
|