Permit Information
Permit NumberBLD15-03223
StatusFinaled
Name SHY-BEE INC
Site Address 415 N MAPLE GROVE RD
Project NameEnviro-Tech Industries, LLC
Customer Number 
ePlanReviewYes
Description
**(ENVIRO-TECH INDUSTRIES, LLC)** Permit is for the remodel 3,000 sq. ft. within a 44,064 sq. ft. building. Work to include: removal of select interior walls, addition of a new exterior 12’ wide wall opening, installation structural columns and beams, concrete slab in-fill, and interior finishes in compliance with Ch. 8 of the 2012 IBC. This building is fully fire sprinklered for area increase. Any alterations to the sprinkler system will require a separate permit and shall comply with NFPA 13 as regulated by the fire department. Note: Special inspection required. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 2/21/20162/22/2016 DONE
This permit finaled on the web by Tim Scheibe
First Notice 2/6/20162/11/2016 DONE
sent in mail 2-12-16
Permanent Occupancy  1/27/2016 DONE
BLD-Final1/22/20161/25/20161/25/2016PPASS
DetailsMike Jordan
Tim Phone #: ###-####. Ok for perm occ.
FIRE-Final Inspection1/22/20161/25/20161/25/2016APASS
DetailsTroy Cobbley
Life safety passed
FIRE-Conference1/21/20161/22/20161/22/2016ADONE
DetailsTroy Cobbley
All items have been corrected except for the bollards and the mag lock sensors/buttons.
BLD-Final1/20/20161/21/20161/21/2016PNR
DetailsMike Jordan
Tim Phone #: ###-####
FIRE-Final Inspection1/20/20161/21/20161/21/2016AFAIL
DetailsTroy Cobbley
Repair all exit signs and emergency lights and provide testing, provide egress sensors/request to exit buttons on the doors utilizing the mag locks, remove thumbturn dead bolts, contact scott arellano for guidence on the too narrow drive way around the south side of building and the now blocked off fire dept access from the adjoinging parking lot due to the new fence and three manual gates to the property that are not shown on the city approved plans.
BLD-Other1/4/20161/5/20161/5/2016APASS
DetailsMike Jordan
Tim-Garage door Phone #: ###-####
FIRE-Final Inspection12/10/201512/11/201512/11/2015AFAIL
DetailsTroy Cobbley
Tim and I discussed the need for a fire alarm permit. Project is not ready for fire life safety yet.
FIRE-Final Inspection11/23/201511/23/201511/24/2015PFAIL
DetailsTroy Cobbley
Not ready for a final due to the fire sprinkler permit in the review status and no fire alarm permit even submitted yet. I did go over emergency light requierments with the electrician.
FIRE-Final Inspection11/10/201511/10/201511/10/2015PFAIL
DetailsTroy Cobbley
Repair all exit signs and emergency lights, provide emergency lighting ina all paths of travel. Fire sprinkler coverage is missing in several rooms and possibly blocked in another with painted sprinkler heads. Sprinkler contractor to provide modifications. Install all ceiling tile. Provide verification that the fire alarm system is being monitored. Fire alarm system notification is missing in many areas and overspaced in others. Fire alarm contractor to provide modifications. Provide single action hardware for all exterior doors. Remove dead bolts from exterior doors. All access controlled egress doors to meet IFC 1008.1.9.8 or 1008.1.9.9. Provide fire extinguishers on mezzanines. The wall layout/mezzanines are not shown on the plans/does not match plans. Please verify with building plan reviewer.

I suggested to the contractor that a fire sprinkler contractor and a fire alarm contractor walk the building and provide code compliant systems.
BLD-Conference11/2/201511/2/201511/2/2015PPART
DetailsMike Jordan
Tim Phone #: ###-####. The 3,000 s.f. remodel portion is completed. Owner is hiring his own trades to complete the remainderr of the work. Owner will need to call for a final inspection after trades are finaled prior to occupancy.
BLD-Final10/23/201510/27/201510/27/2015AFAIL
DetailsMike Jordan
Tim Phone #: ###-####. Provide all special inspection reports, Permits shows that mech, electrical and plumbing permits are required. A fire/life/safety final inspection is required. Also framing for fur down? A correrction notice was issued.
Print Occupancy Form  10/13/2015 DONE
Issue PAID IN FULL permit  10/13/2015 DONE
OVERRIDE  10/6/2015  
Plan assigned to (JG)9/24/20159/24/201510/6/2015 PASS
DetailsJavier Guzman
1st review completed, Pending Sp. Insp form, 10/07 L2 Enviro - Tech
Plan resubmittals received  10/6/2015 DONE
received one copy of #310 form- put with plans on Javier's desk
Routing - PLAN CHECK10/6/2015 10/6/2015 PASS
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  10/6/2015 DONE
Permit Ready to Issue  10/6/2015 DONE
NEED RP, GC FORM AND REVISED CERT OF VALUE
1st review completed  10/5/2015 FAIL
DetailsJavier Guzman
Routing - PLAN CHECK9/24/2015 10/5/2015 FAIL
DetailsJavier Guzman
Pending special inspection form from engineer
Routing - FIRE9/24/20159/24/20159/28/2015 PASS
DetailsKatie Marron
Report attached to case.
Routing - Erosion and Sediment9/24/2015 9/25/2015 PASS
DetailsEvan Jenkins
Demolition 2 walls and add exterior garage ground level door
Intake Approval  9/24/2015 PASS
DetailsDavid Ferguson
Routing - Addressing9/24/2015 9/24/2015 PASS
DetailsEmily Dixon
Routing - PUBLIC WORKS9/24/2015 9/24/2015 PASS
DetailsJennifer Bruner
Routing - Design Review9/24/2015 9/24/2015 PASS
DetailsAndrea Tuning
Intake Approval  9/23/2015 FAIL
DetailsDavid Ferguson
Tim, after reviewing your latest submittal, it appears that the following items are still needed.
1) Upload each large plan sheet individually so that all 3 sheets are not in one file
2) Provide a Table of Contents on the Cover Page
3) Provide a Zoning Certificate from our Planning Department (Andrea Tunning can probably help with this)

If you run into difficulties with our ePlan review system, please contact Christina Prado at ###-#### for assistance.
Intake Approval  9/17/2015 FAIL
DetailsDavid Ferguson
Please see the redlined Checklist that you submitted for missing items. These include the following:
1) No Key Plan
2) No exterior elevations for new door
3) No Table of Contents
4) No approval letter from Planning for the exterior changes
5) No Erosion and Sediment Control waiver from Erosion Control
Intake Approval  9/15/2015 FAIL
DetailsDavid Ferguson
Checklist was not uploaded
Application received  9/6/2015 DONE
Application submitted via PDS Online on Sep 6 2015 12:38PM