Information based on query as of Saturday, June 22, 2024.
Permit Information
Permit NumberBLD15-03826
StatusFinaled
Name CLEAR CREEK CONSTRUCTION LLC
Site Address 2789 S BROADWAY AVE
Project NameJimmy John's
Customer Number 
ePlanReviewNo
Description
(JIMMY JOHN’S – INTERIOR TENANT IMPROVEMENT) (DRH15-00377) The fire sprinkler system is used for building area increase and for fire area. To prepare an existing 1,511 square foot tenant space for a new restaurant tenant. Work is to include interior nonbearing walls, 2 restrooms accessible to the disabled, seven (7) inch high elevated concrete platforms for fixed seating, gypsum board soffits, suspended acoustical ceilings, millwork, and finishes. Exterior work for the drive thru was done under permit BLD15-01982 and interior non-structural demolition work was done under permit BLD15-03969. The drawings show 40 dining surfaces two of which are required to be accessible to the disabled. The drive thru window was installed in a new opening in an existing masonry wall. An adequate header is required above the new opening to support gravity loads. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. Separate fire sprinkler permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 5/17/20166/10/2016 DONE
Second Notice 4/22/20165/12/2016 DONE
Mailed 5-13-16
First Notice 3/12/20164/12/2016 DONE
DetailsCandy A. Nichols
sent 4-13-16
BLD-Final3/2/20163/2/20163/2/2016PPASS
DetailsJim Storey
Marvin Phone #: ###-#### need zonning signoff
Zoning Approval3/2/20163/2/20163/2/2016 DONE
DetailsLeon Letson
Approved with Inspection of BLD15-01982
Permanent Occupancy  3/2/2016 DONE
BLD-Final1/19/20161/20/20161/20/2016PPART
DetailsJim Storey
Marvin Phone #: ###-#### need zoning and health dept sign off
FIRE-Final Inspection1/19/20161/20/20161/20/2016APASS
DetailsJim Page
Fire sprinkler inspection complete, no fire alarms to inspect. Life fire safety passed/complete.
BLD-Ceiling Grid Inspection1/15/20161/15/20161/15/2016PPASS
DetailsJim Storey
Marvin Phone #: ###-####
BLD-Energy code compliance12/7/201512/8/201512/8/2015APASS
DetailsJim Storey
Marvin Phone #: ###-####
BLD-Framing/Rough-in12/3/201512/4/201512/4/2015APASS
DetailsJim Storey
Marvin Phone #: ###-#### ok pending plm insp pm
Plan assigned to (CJW)10/19/201510/19/201511/12/2015 PASS
DetailsCarl Westfall
(1st done) JIMMY JOHN'S (Nov 6 - 15 days) Level 3 TI - Paper
Routing - PLAN CHECK11/10/2015 11/12/2015 PASS
DetailsCarl Westfall
PLANS/APPL TAKEN TO FRONT DESK  11/12/2015 DONE
Print Occupancy Form  11/12/2015 DONE
Permit Ready to Issue  11/12/2015 DONE
all requirements met
Telephone call  11/12/2015 DONE
called Marvin to let know permit is ready and how much is owed-left message on phone
Issue PAID IN FULL permit  11/12/2015 DONE
Routing - FIRE11/10/201511/10/201511/10/2015 PASS
DetailsKatie Marron
Item resolved under BLD15-01982. Updated report attached to plans.
Routing - MECHANICAL11/9/2015 11/10/2015 PASS
DetailsTroy James
Routing - PLAN CHECK11/5/2015 11/9/2015  
DetailsCarl Westfall
On hold at Carl Westfall's desk
Plan resubmittals received  11/9/2015 DONE
Two copies of sheets M-1, M-2, E-1,and E-3. Taken to Carl W
Routing - PLAN CHECK11/9/2015 11/9/2015 PASS
DetailsCarl Westfall
Prep drawings for routing
Routing - FIRE11/4/2015 11/5/2015 FAIL
DetailsKatie Marron
Proposed modifications to drive aisle not allowed, drive aisle is required for fire department vehicle access. Report attached to plans and emailed to applicant.
1st review completed  11/5/2015 FAIL
Failed Fire and Mechanical
Routing - PLAN CHECK10/29/2015 11/4/2015 PASS
DetailsCarl Westfall
Drawings approved with code notes
Routing - Design Review10/28/2015 10/29/2015 PASS
DetailsJosh Wilson
ok per DRH15-00377
Routing - PLANNING10/20/2015 10/27/2015 PASS
DetailsLeon Letson
Leon Letson - CUP15-00008
Routing - PLUMBING10/23/2015 10/27/2015 PASS
DetailsBill VanDegrift
1)Unite Water requires an R.P. upstream of filters
2) R.P. required upstream of water cooled compressors( ice maker)
3) R.P. required at soda machines
4) additional cross connection protection may be required
Routing - MECHANICAL10/23/2015 10/23/2015 FAIL
DetailsTroy James
emailed mechanical correction to applicant
Routing - Erosion and Sediment10/21/2015 10/22/2015 CANC
DetailsEvan Jenkins
No ESC Permit Required for the BLD Permit: Evan Jenkins
Routing - Addressing10/19/2015 10/20/2015 PASS
DetailsJason C. Taylor
Routing - PUBLIC WORKS10/20/2015 10/20/2015 PASS
DetailsRachael Beierle
Plans ACCEPTED BY PLAN TECH  10/19/2015 DONE
Recd Pcfee & Taken To Pln CK  10/19/2015 DONE
Intake Approval  10/19/2015 PASS
DetailsCarl Westfall
Pending Assignment by JCB10/19/2015 10/19/2015 DONE
DetailsJason Blais
Intake Approval  6/26/2015 FAIL
DetailsCarl Westfall
i accidently printed the perm c of o but should have issued the temp c of o
Application received 10/19/2015