Permit Information
Permit NumberBLD15-04159
StatusFinaled
Name ANDERSEN CONSTRUCTION CO
Site Address 1055 N CURTIS RD
Project NameSARMC Microbiology Remodel
Customer Number 
ePlanReviewYes
Description
**(SAINT ALPHONSUS REGIONAL MEDICAL CENTER – 1st STORY – MICROBIOLOGY REMODEL)** Fire sprinkler system used for occupancy and for high-rise. Permit to remodel 1,118 sq. ft. within the existing building of the Saint Alphonsus Regional Medical Center. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, new door openings into smoke partition, remove select suspended ceiling work and millwork, construction of select interior nonbearing walls, select wall infill, new select suspended ceiling, light fixtures, electrical work, plumbing work, mechanical work, and interior finishes in compliance with Ch. 8 of the 2012 IBC. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 6/15/20166/22/2016 DONE
This permit finaled on the web by Robbin Zahurak
Second Notice 5/22/20166/10/2016 DONE
Case Summary (BLD)  5/18/2016 DONE
Letter of compliance/Occupancy  5/18/2016 DONE
First Notice5/10/20165/10/20165/12/2016 DONE
DetailsMike Jordan
Mailed 5-13-16
BLD-Final5/10/20165/10/20165/10/2016PPASS
DetailsMike Jordan
Brad Turk Phone #: ###-#### Inspection requested via web by Brad Turk
DOC - Permit Finaled5/10/20165/10/20165/10/2016PPASS
DetailsMike Jordan
FIRE-Final Inspection5/9/20165/9/20165/9/2016PPASS
DetailsTroy Cobbley
Life safety passed
BLD-Ceiling Grid Inspection4/27/20164/28/20164/28/2016PPASS
DetailsMike Jordan
Brad Turk. Phone #: ###-#### Inspection requested via web by Brad Turk
BLD-Framing/Rough-in4/6/20164/7/20164/7/2016PPASS
DetailsMike Jordan
Brad Turk
Meet in the Andersen St. Al''s Field office. Phone #: ###-#### Inspection requested via web by Brad Turk
Issue PAID IN FULL permit  1/4/2016 DONE
Inspection Record Card- Bld  1/4/2016 DONE
Plan assigned to (JG)12/2/201512/2/201512/2/2015 PASS
DetailsJavier Guzman
12/02 L2 Microbiology T.I.
Plan assigned to (JG)11/19/201511/19/201512/2/2015 PASS
DetailsJavier Guzman
12/02 L2 Microbiology T.I.
Routing - PLAN CHECK11/19/2015 12/2/2015 PASS
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  12/2/2015 DONE
Permit Ready to Issue  12/2/2015 DONE
**requirments met 12-15-15
Need GC and Revised Cert of Value
1st review completed  12/2/2015 DONE
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  12/2/2015 DONE
Routing PW Environmental12/2/2015 12/2/2015 PASS
DetailsRick Christenson
Routing - MECHANICAL12/1/2015 12/1/2015 PASS
DetailsTroy James
Routing - FIRE11/19/201511/19/201511/19/2015 PASS
DetailsKatie Marron
Comments attached to case.
Intake Approval  11/19/2015 PASS
DetailsJavier Guzman
Routing - PLUMBING11/19/2015 11/19/2015 PASS
DetailsBill VanDegrift
remodel
Routing - Addressing11/19/2015 11/19/2015 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS11/19/2015 11/19/2015 PASS
DetailsRachael Beierle
Intake Approval  11/16/2015 FAIL
DetailsDavid Ferguson
Please complete filling out the checklist. Also, I notice that several pages have not been stamped by and architect. Are you proposing that you qualify for one of the three exceptions. If so, please circle the one that you feel you qualify for.
Intake Approval  11/16/2015 FAIL
DetailsDavid Ferguson
Please complete filling out the checklist #518.
Application received  11/13/2015 DONE
Application submitted via PDS Online on Nov 13 2015 8:24AM
Intake Approval  11/13/2015 FAIL
DetailsDavid Ferguson
Please fill out and upload form #518 Minor Improvement Checklist and #304 Registered Design Professional form and all of the documents that are pertinent to this project. Also, please note that we require all of the plan sheets (large documents) to be uploaded horizontally and not vertically as you have done.