Permit Information
Permit NumberBLD16-00167
StatusFinaled
Name EKC INC
Site Address 1249 S VINNELL WAY Unit: 103
Project NameHUD - Suite 103
Customer Number 
ePlanReviewYes
Description
** (HUD - Suite 103) ** Permit is to remodel an existing first floor 1,842 sq. ft. tenant space within a 60,280 sq. ft. building. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing wall, construction of select interior nonbearing walls to create a an office, a conference room, a break room, a health room, a reception area, a LAN room and open office areas, new millwork, new acoustic suspended ceiling, new sinks at the health and break rooms, relocating existing light fixtures, plumbing work, electrical work, mechanical work and interior finishes to be in compliance with Ch. 8 of the 2012 IBC. Note: new portion of corridor wall is a 2 hour rated wall assembly. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 6/17/20176/20/2017 DONE
This permit finaled on the web by Cecyle Brock
Third Notice 5/15/20176/12/2017 DONE
Mailed 6-13-17
Second Notice 4/21/20175/10/2017 DONE
sent in mail 5-11-17
First Notice 3/20/20174/11/2017 DONE
Mailed 4-12-17
Permanent Occupancy  3/10/2017 DONE
BLD-Final5/11/20165/12/20165/12/2016PPASS
DetailsMike Jordan
Randy Phone #: ###-####. Ok for perm occ.
FIRE-Final Inspection5/9/20165/9/20165/9/2016PPASS
DetailsTroy Cobbley
fire life safety. passed
BLD-Ceiling Grid Inspection4/19/20164/20/20164/20/2016PPASS
DetailsMike Jordan
Randy Phone #: ###-####
BLD-Other3/24/20163/24/20163/24/2016PPASS
DetailsMike Jordan
Randy Phone #: ###-####. 2hr. corridor construction ok.
BLD-Framing/Rough-in3/21/20163/22/20163/22/2016APASS
DetailsMike Jordan
Randy Phone #: ###-####
Issue PAID IN FULL permit  3/1/2016 DONE
Print Occupancy Form  3/1/2016 DONE
Plan assigned to (JG)2/12/20162/12/20162/22/2016 PASS
DetailsJavier Guzman
1st review completed, 2/25 L2 HUD TI ePlan
Routing - PLAN CHECK2/22/2016 2/22/2016 PASS
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  2/22/2016 DONE
Permit Ready to Issue  2/22/2016 DONE
DetailsChristina Prado
Need GC form & Revised certificate of value for issuance--- requirements met 2-25-16 KRS
Routing - PLAN CHECK2/12/2016 2/19/2016 FAIL
DetailsJavier Guzman
ePlan
1st review completed  2/19/2016 FAIL
DetailsJavier Guzman
Routing - Addressing2/12/2016 2/12/2016 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS2/12/2016 2/12/2016 PASS
DetailsRachael Beierle
Intake Approval  2/12/2016 PASS
DetailsJavier Guzman
Application received  1/20/2016 DONE
Application submitted via PDS Online on Jan 20 2016 11:20AM