BLD-Conference | 9/29/2016 | 9/30/2016 | 9/30/2016 | A | PASS |
Tony Young
|
|
|
Garage code 0713. Please call Steve 208.850.8424 with any questions. Thank you, steve... verify address,, 2622 .vs 2628,, permit has been changed to proper address
|
DOC - Permit Finaled | 9/30/2016 | 9/30/2016 | 9/30/2016 | P | PASS |
Tony Young
|
|
|
done
|
BLD-Final | 9/27/2016 | 9/29/2016 | 9/29/2016 | A | PEND |
Tony Young
|
|
|
Final inspection for C of O. Plans on the counter inside. Garage code 0713. Please call Steve 208.850.8424 with any questions. Thank you, steve Phone #: ###-#### Inspection requested via web by steve hanson,, all ok,, just need to verify address,, permit .vs house #s
|
BLD-Wall Bracing | 6/30/2016 | 7/5/2016 | 7/5/2016 | A | PASS |
Tony Young
|
|
|
Exterior shear inspection completed and passed. This inspection is for Drywall Shear inspection. Several areas inside with 7" screw pattern completed. Call Steve with any questions. Thank you, steve Phone #: ###-#### Inspection requested via web by steve hanson
|
BLD-Energy code compliance | 6/27/2016 | 6/28/2016 | 6/28/2016 | A | PASS |
Tony Young
|
|
|
Need a framing re-inspect ; an energy inspection. We have the ''tempered glass'' ordered for the window next to the front door. Once the glass is here this will be changed out. Any questions please give me a call. Thanks! Phone #: ###-#### Inspection requested via web by Kim Winkle
|
BLD-Framing/Rough-in | 6/22/2016 | 6/24/2016 | 6/24/2016 | A | PART |
Phil Shearer
|
|
|
Phone #: ###-#### Inspection requested via web by Kim Winkle. point load for beam over fireplace and beam to the right of the fireplace. OK to insulate
|
BLD-Wall Bracing | 6/10/2016 | 6/13/2016 | 6/13/2016 | A | PART |
Tony Young
|
|
|
Phone #: ###-#### Inspection requested via web by Kim Winkle,, exterior ok
|
BLD-Foundation | 5/12/2016 | 5/12/2016 | 5/12/2016 | P | PASS |
Phil Shearer
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Foundation | 5/11/2016 | 5/12/2016 | 5/12/2016 | A | NR |
Phil Shearer
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 5/10/2016 | 5/10/2016 | 5/10/2016 | P | PART |
Tony Young
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron,, work in progess
|
BLD-Footing | 5/9/2016 | 5/10/2016 | 5/10/2016 | A | NR |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron. Footings excavated. No one here, no forms on site, no lot lines strung. Needs to reschedule inspection.
|
BLD-Conference | 5/3/2016 | 5/4/2016 | 5/4/2016 | A | PASS |
Dave Hannah
|
|
|
Need erosion control inspection prior to dig. STeve is site contact at 850.8424. thanks. steve Phone #: ###-#### Inspection requested via web by steve hanson
|
Issue PAID IN FULL permit | | | 4/26/2016 | | DONE |
|
|
|
|
OVERRIDE | | | 2/25/2016 | | |
|
|
|
|
Plan assigned to (DAF) | 2/1/2016 | 2/1/2016 | 2/25/2016 | | DONE |
David Ferguson
|
|
|
due 2/11 - Need tall wall engineering, roof plan(or truss specs), column sizes
|
Inspection Record Card- Bld | | | 2/25/2016 | | DONE |
|
|
|
|
Telephone call | | | 2/25/2016 | | DONE |
|
|
|
called Steve- left a message that permit is ready for pick up and fees due
|
Routing - PLAN CHECK | 2/25/2016 | | 2/25/2016 | | PASS |
David Ferguson
|
|
|
|
Case Summary (BLD) | | | 2/25/2016 | | DONE |
David Ferguson
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 2/25/2016 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 2/25/2016 | | DONE |
|
|
|
All Met
|
Route to Impact Fee Review | 2/8/2016 | 2/11/2016 | 2/10/2016 | | PASS |
Cindy M. Gould
|
|
|
|
1st review completed | | | 2/8/2016 | | FAIL |
David Ferguson
|
|
|
|
Routing - PLAN CHECK | | | 2/8/2016 | | FAIL |
David Ferguson
|
|
|
|
Routing - MECHANICAL | 2/1/2016 | | 2/2/2016 | | PASS |
Troy James
|
|
|
|
Routing - PLANNING | 1/29/2016 | | 2/1/2016 | | PASS |
Colleen T Carroll
|
|
|
|
Plan assigned to (LEG) Tisha | 1/28/2016 | | 2/1/2016 | | DEFR |
Tisha Gallop
|
|
|
|
Routing - PUBLIC WORKS | 1/28/2016 | | 1/29/2016 | | PASS |
Jennifer Bruner
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 1/28/2016 | | DONE |
|
|
|
|
Intake Approval | | | 1/28/2016 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 1/28/2016 | | DONE |
|
|
|
|
Routing - Addressing | 1/28/2016 | | 1/28/2016 | | PASS |
Laura Hunter
|
|
|
|
Application received | | 1/28/2016 | | | |
|
|
|
|