BLD-Final | 7/26/2017 | 7/26/2017 | 7/26/2017 | P | PASS |
Tony Young
|
|
|
Pete Phone #: ###-####,, all ok now
|
Permanent Occupancy | | | 7/26/2017 | | DONE |
|
|
|
|
PubWorks Occupancy Approval | 7/25/2017 | 7/25/2017 | 7/25/2017 | | DONE |
Tiffany Lowery
|
|
|
|
Zoning Approval | 7/21/2017 | 7/21/2017 | 7/21/2017 | | DONE |
Andrea Tuning
|
|
|
|
BLD-Final | 7/13/2017 | 7/13/2017 | 7/13/2017 | P | PART |
Tony Young
|
|
|
Pete Phone #: ###-####,, pod 1 and 2 ok for temp occupancy
|
FIRE-Final Inspection | 7/12/2017 | 7/13/2017 | 7/13/2017 | A | PASS |
Jim Page
|
|
|
Fire sprinkler inspection complete, fire alarm inspection complete, fire extinguishers are in place with current inspection tags and knox box is in place by fire riser room, building fire safety and evacuation plan documents will be placed in units when construction is complete. Final life fire safety inspection passed/complete.
|
Temporary Occupancy | 7/13/2017 | 10/11/2017 | 7/13/2017 | | DONE |
Tisha Gallop
|
|
|
Per Angie Brosious ok to issue TCO for pods 1 & 2 without any sign off from ACHD
|
PubWorks Temp Occupancy Appr | 7/13/2017 | 7/13/2017 | 7/13/2017 | | DONE |
Tiffany Lowery
|
|
|
|
BLD-Conference | 7/10/2017 | 7/11/2017 | 7/11/2017 | A | PART |
Tony Young
|
|
|
Pete Phone #: ###-####,, pod 1 and 2 walk through,, door lables,, hardware,, address,, other misc.
|
BLD-Energy code compliance | 6/6/2017 | 6/6/2017 | 6/6/2017 | P | PASS |
Dave Hannah
|
|
|
Retail space insulation Phone #: ###-#### Inspection requested via web by Bob Ledford
|
BLD-Framing/Rough-in | 6/6/2017 | 6/6/2017 | 6/6/2017 | P | PASS |
Dave Hannah
|
|
|
Pod #3 Live Work, framing at demising wall Phone #: ###-#### Inspection requested via web by Bob Ledford
|
BLD-Framing/Rough-in | 6/2/2017 | 6/5/2017 | 6/6/2017 | P | PART |
Dave Hannah
|
|
|
Retail space at ground level northeast corner, including demising wall with Live work space #6 pod 3 Phone #: ###-#### Inspection requested via web by Bob Ledford ok to insulate work/tenent side
|
BLD-Energy code compliance | 6/1/2017 | 6/2/2017 | 6/2/2017 | P | PASS |
Jim Sly
|
|
|
PM Live work #6, Pod #3, energy code. Phone #: ###-#### Inspection requested via web by Bob Ledford
|
BLD-Framing/Rough-in | 6/1/2017 | 6/2/2017 | 6/2/2017 | A | PART |
Jim Sly
|
|
|
AM Live work #6, Pod #3, framing Phone #: ###-#### Inspection requested via web by Bob Ledford All OK except......East wall.
|
BLD-Framing/Rough-in | 5/26/2017 | 5/26/2017 | 5/26/2017 | P | PASS |
Tony Young
|
|
|
Pete-garage Phone #: ###-####,, ok to insulate
|
BLD-Energy code compliance | 5/26/2017 | 5/26/2017 | 5/26/2017 | P | PASS |
Tony Young
|
|
|
Pete-2nd floor Phone #: ###-####
|
BLD-Energy code compliance | 5/24/2017 | 5/25/2017 | 5/25/2017 | A | PASS |
Tony Young
|
|
|
Pete Phone #: ###-####
|
BLD-Wall cover | 5/24/2017 | 5/25/2017 | 5/25/2017 | A | PASS |
Tony Young
|
|
|
2nd floor // Pete Phone #: ###-####,, soffits east side
|
BLD-Framing/Rough-in | 5/23/2017 | 5/24/2017 | 5/24/2017 | A | PASS |
Tony Young
|
|
|
2nd floor // Pete Phone #: ###-####
|
BLD-Framing/Rough-in | 5/23/2017 | 5/23/2017 | 5/23/2017 | A | PART |
Dave Hannah
|
|
|
Pete Phone #: ###-####, Pod 3, 2nd and 3rd floors ok to insulate 3rd fl pod 3
|
BLD-Framing/Rough-in | 5/19/2017 | 5/22/2017 | 5/23/2017 | A | NR |
Tony Young
|
|
|
Pete Phone #: ###-####
|
FIRE-Conference | 5/19/2017 | 5/22/2017 | 5/22/2017 | P | DONE |
Jim Page
|
|
|
Fire conference complete
|
BLD-Energy code compliance | 5/16/2017 | 5/17/2017 | 5/17/2017 | A | PASS |
Tony Young
|
|
|
Pete Phone #: ###-####
|
BLD-Framing/Rough-in | 5/15/2017 | 5/15/2017 | 5/15/2017 | P | PART |
Dave Hannah
|
|
|
Pete Phone #: ###-#### ok to insulate 1st floor pod 4
|
BLD-Energy code compliance | 5/11/2017 | 5/11/2017 | 5/11/2017 | P | PASS |
Brandon Shaw
|
|
|
As late in the afternoon as possible // Pete Phone #: ###-#### Second story, second pod
|
BLD-Framing/Rough-in | 5/9/2017 | 5/10/2017 | 5/10/2017 | P | PASS |
Tony Young
|
|
|
Pete-2nd floor Phone #: ###-####,, ok to insulate pending trades
|
BLD-Energy code compliance | 5/9/2017 | 5/9/2017 | 5/9/2017 | P | PART |
Dave Hannah
|
|
|
Pete Phone #: ###-#### third fl pod 4 ok
|
BLD-Framing/Rough-in | 5/5/2017 | 5/8/2017 | 5/8/2017 | A | PASS |
Dave Hannah
|
|
|
pete Phone #: ###-#### third floor pod 4 ok to insulate
|
FIRE-Conference | 4/28/2017 | 5/1/2017 | 5/1/2017 | A | PART |
Jim Page
|
|
|
Fire conference complete, awaiting answer from fire sprinkler plan reviewer for acceptance of proposed method to prevent pipe from freezing over top of breezeway.
|
BLD-Energy code compliance | 4/26/2017 | 4/27/2017 | 4/27/2017 | A | PASS |
Tony Young
|
|
|
Pete Phone #: ###-####,, soffit areas on exterior beyond support beams on north/east ok to cover
|
BLD-Framing/Rough-in | 4/24/2017 | 4/24/2017 | 4/24/2017 | P | PART |
Tony Young
|
|
|
Pete Phone #: ###-####,, ok to insulate soffit areas,, letter from engineer to plan review
|
BLD-Framing/Rough-in | 4/21/2017 | 4/24/2017 | 4/24/2017 | A | PART |
Tony Young
|
|
|
Pete Phone #: ###-####,, soffit areas,, ok pending approval from engineer
|
OVERRIDE | | | 4/21/2017 | | |
|
|
|
|
Plan assigned to (CJW) | 4/5/2017 | 4/5/2017 | 4/21/2017 | | PASS |
Carl Westfall
|
|
|
1st plan mod - 1401 Idaho - old watercooler site
|
CHANGE STATUS TO (ISS) | | | 4/21/2017 | | DONE |
|
|
|
Plan Mod
|
Plan Reviewer's activity | | | 4/21/2017 | | DONE |
|
|
|
Plan modification approved and sent to the permits desk.
|
Permit Ready to Issue | | | 4/21/2017 | | DONE |
|
|
|
DO NOT REISSUE PLAN MOD
|
Routing Off Site - STRUCTURAL | 4/5/2017 | | 4/21/2017 | | PASS |
Carl Westfall
|
|
|
Jared Bauder (CH2MHill)
|
(F) Reprint permit | | | 4/21/2017 | | DONE |
|
|
|
|
BLD-Energy code compliance | 4/12/2017 | 4/13/2017 | 4/13/2017 | A | PART |
Tony Young
|
|
|
Energy // Pete Phone #: ###-####,, same areas as frame,, electric room, east soffit on pod 3 ok
|
BLD-Framing/Rough-in | 4/10/2017 | 4/10/2017 | 4/10/2017 | P | PART |
Mike Jordan
|
|
|
Pete-pod 2 and electric room and exterior facet in pod 4 Phone #: ###-#### Ok to insulate electrical room, need to complete column wraps. framing at pod soffits ok, ok to insulate.
|
BLD-Energy code compliance | 4/6/2017 | 4/7/2017 | 4/7/2017 | P | PASS |
Tony Young
|
|
|
Pete-pod 2-1st floor Phone #: ###-####
|
BLD-Framing/Rough-in | 4/4/2017 | 4/5/2017 | 4/5/2017 | P | PASS |
Tony Young
|
|
|
Pete-1st floor Phone #: ###-####, ok to insulate
|
BLD-Energy code compliance | 4/4/2017 | 4/5/2017 | 4/5/2017 | A | PASS |
Tony Young
|
|
|
Pete-2nd floor Phone #: ###-####
|
Plan Modification Accepted | | | 4/5/2017 | | DONE |
Christina Prado
|
|
|
Plan Mod to modify to cantilever beam framing-POD # 3
|
Routing - PLAN CHECK | 4/5/2017 | | 4/5/2017 | | DONE |
Carl Westfall
|
|
|
Routed to the Consultant Structural Engineer to review the 1st plan mod.
|
BLD-Energy code compliance | 4/3/2017 | 4/4/2017 | 4/4/2017 | A | PASS |
Tony Young
|
|
|
pete Phone #: ###-####,, room ok as noted before
|
BLD-Energy code compliance | 3/31/2017 | 4/3/2017 | 4/3/2017 | A | PASS |
Mike Jordan
|
|
|
Deek Phone #: ###-####. POd #2 3rd floor ok, except for unit #306.
|
BLD-Framing/Rough-in | 3/28/2017 | 3/28/2017 | 3/28/2017 | P | DONE |
Mike Jordan
|
|
|
Phone #: ###-####. Ok to insualte.
|
BLD-Framing/Rough-in | 3/27/2017 | 3/27/2017 | 3/27/2017 | P | PART |
Tony Young
|
|
|
Pete Phone #: ###-####,, upper level ok,, ok to insulate,, pod 2
|
BLD-Wall Bracing | 3/17/2017 | 3/17/2017 | 3/17/2017 | P | PART |
Tony Young
|
|
|
Shear // Pete Phone #: ###-####,, exterior shear ok
|
BLD-Framing/Rough-in | 3/15/2017 | 3/15/2017 | 3/15/2017 | P | PART |
Tony Young
|
|
|
Pete Phone #: ###-####,, roof nailing,, self certified
|
BLD-Blower Door Test Results | 3/8/2017 | 3/9/2017 | 3/9/2017 | A | PASS |
Tony Young
|
|
|
Pete-soffit and drop ceiling Phone #: ###-####,, pod 1
|
BLD-Energy code compliance | 3/7/2017 | 3/7/2017 | 3/7/2017 | P | PASS |
Tony Young
|
|
|
Pete Phone #: ###-####,, pod 1 storage room riser room,, garage,, 1st floor ok
|
BLD-Framing/Rough-in | 3/2/2017 | 3/3/2017 | 3/3/2017 | A | PASS |
Tony Young
|
|
|
1st Floor.... Late morning // Pete Phone #: ###-####,, 1st floor on pod 1 ok to insulate,, need to verify if straps are needed and if headers on front wall are needed
|
BLD-Energy code compliance | 3/2/2017 | 3/2/2017 | 3/2/2017 | P | PASS |
Tony Young
|
|
|
Second floor - Pete Phone #: ###-####
|
BLD-Framing/Rough-in | 2/28/2017 | 3/1/2017 | 3/1/2017 | A | PASS |
Tony Young
|
|
|
Pod 1 - 2nd floor, Pete Phone #: ###-####// ok to insulate
|
BLD-Wall Bracing | 2/27/2017 | 2/28/2017 | 2/28/2017 | P | PART |
Tony Young
|
|
|
Pod 3 - Pete Phone #: ###-####,,
|
BLD-Other | 2/24/2017 | 2/27/2017 | 2/27/2017 | P | PART |
Tony Young
|
|
|
Late, please for Insulation over fire sprinkler - Pete Phone #: ###-####,, ok pending sprinkler permit tenting pass,, 3rd floor west pod
|
BLD-Energy code compliance | 2/24/2017 | 2/27/2017 | 2/27/2017 | A | NR |
Tony Young
|
|
|
Pete Phone #: ###-####,, pod 1,, upper level
|
BLD-Energy code compliance | 2/24/2017 | 2/27/2017 | 2/27/2017 | A | NR |
Tony Young
|
|
|
Pete Phone #: ###-####
|
BLD-Energy code compliance | 2/24/2017 | 2/24/2017 | 2/24/2017 | P | NR |
Tony Young
|
|
|
Pete Phone #: ###-####,, needs fire pass
|
BLD-Framing/Rough-in | 2/22/2017 | 2/23/2017 | 2/23/2017 | P | PART |
Tony Young
|
|
|
As last as possible // Pete Phone #: ###-####,, pod 1 3rd floor ok to insulate
|
BLD-Wall Bracing | 2/13/2017 | 2/14/2017 | 2/14/2017 | P | PART |
Tony Young
|
|
|
Pete Phone #: ###-####,, pod 1 interior shear ok and 2nd level on pod 3 ok to stand interior wall
|
BLD-Conference | 1/31/2017 | 2/1/2017 | 2/1/2017 | A | PEND |
Tony Young
|
|
|
Pete Phone #: ###-####,, ?s about split occupancy
|
FIRE-Conference | 1/31/2017 | 2/1/2017 | 2/1/2017 | A | DONE |
Jim Page
|
|
|
Fire conference complete
|
BLD-Conference | 1/30/2017 | 1/31/2017 | 1/31/2017 | P | CANC |
Dave Hannah
|
|
|
Pete Phone #: ###-####
|
FIRE-Conference | 1/30/2017 | 1/31/2017 | 1/31/2017 | P | CANC |
Jim Page
|
|
|
Conference rescheduled for 01FEB2017
|
BLD-Wall Bracing | 1/9/2017 | 1/9/2017 | 1/9/2017 | P | PART |
Tony Young
|
|
|
Joe// please call before Phone #: ###-####,, exterior shear nailing,, ok with minor fixes
|
BLD-Framing/Rough-in | 12/20/2016 | 12/21/2016 | 12/21/2016 | P | NR |
Tony Young
|
|
|
Joe Phone #: ###-####,, walk through only
|
BLD-Wall Bracing | 12/20/2016 | 12/21/2016 | 12/21/2016 | P | PART |
Tony Young
|
|
|
Joe Phone #: ###-####,, work in progress on grid 4,, 4th floor,, ok
|
BLD-Conference | 12/7/2016 | 12/12/2016 | 12/15/2016 | A | PEND |
Tony Young
|
|
|
Joe Phone #: ###-####,, firewall continuation ?,, see plan review
|
BLD-Conference | 12/6/2016 | 12/7/2016 | 12/7/2016 | A | PEND |
Tony Young
|
|
|
Joe Phone #: ###-####,, firewall continuation ?,, see plan review,,
|
BLD-Framing/Rough-in | 12/5/2016 | 12/6/2016 | 12/6/2016 | P | PART |
Tony Young
|
|
|
Joe Phone #: ###-####,, upper shear wall same as last lower,, ok,, wip
|
BLD-Wall Bracing | 10/24/2016 | 10/24/2016 | 10/24/2016 | P | PART |
Tony Young
|
|
|
Joe// 3pm works best Phone #: ###-####,, line 7 shear nailing ok
|
BLD-Wall Bracing | 10/17/2016 | 10/18/2016 | 10/18/2016 | P | PART |
Tony Young
|
|
|
Pat Phone #: ###-####,, met with Nate the frame foreman,, grid 1-4 and west side of 4-7 shear ok,, fire blocks via insulation between walls in place
|
BLD-Foundation | 10/5/2016 | 10/6/2016 | 10/6/2016 | A | PART |
Dave Hannah
|
|
|
Joe Phone #: ###-#### planters
|
BLD-Foundation | 9/21/2016 | 9/22/2016 | 9/22/2016 | A | PASS |
Mike Jordan
|
|
|
Joe-stem wall-pour time 12:30 Phone #: ###-####. Gridlines 8.3 to 12 and E to H.
|
BLD-Footing | 9/13/2016 | 9/15/2016 | 9/15/2016 | A | PEND |
Dave Hannah
|
|
|
Concrete at 10AM - Joe Phone #: ###-#### ok after mti signs off
|
BLD-Concrete | 9/8/2016 | 9/8/2016 | 9/8/2016 | P | PEND |
Tony Young
|
|
|
Concrete at 4am // Joe Phone #: ###-####,, north area slab and interior slab footings,, special inspector will be on site,, work in progress
|
BLD-Footing | 8/30/2016 | 9/1/2016 | 9/1/2016 | P | NR |
Phil Shearer
|
|
|
concret slab wand struc footings-pour time Friday 4:00 AM Phone #: ###-####
|
BLD-Concrete | 8/25/2016 | 8/26/2016 | 8/26/2016 | A | PART |
Tony Young
|
|
|
11:00am pour; Joe Phone #: ###-####
|
BLD-Footing | 8/19/2016 | 8/22/2016 | 8/22/2016 | A | PEND |
Tony Young
|
|
|
Joe-concrete footing placement-pour time 1:00 Phone #: ###-####
|
BLD-Concrete | 8/18/2016 | 8/19/2016 | 8/19/2016 | A | PASS |
Jim Storey
|
|
|
Concrete at 1230 // Joe Phone #: ###-#### walls grid line 4-7 ok
|
BLD-Concrete | 8/11/2016 | 8/15/2016 | 8/15/2016 | A | PART |
Tony Young
|
|
|
Joe Phone #: ###-####-pour time 12:30,, special inspection pending
|
BLD-Foundation | 8/11/2016 | 8/12/2016 | 8/12/2016 | A | PEND |
Tony Young
|
|
|
Joe Phone #: ###-####,, special inspector on site
|
BLD-Footing | 8/3/2016 | 8/5/2016 | 8/5/2016 | P | PASS |
Phil Shearer
|
|
|
Joe Phone #: ###-####
|
Print Occupancy Form | | | 6/10/2016 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 6/10/2016 | | DONE |
|
|
|
|
OVERRIDE | | | 5/11/2016 | | |
|
|
|
|
Plan assigned to (CJW) | 2/23/2016 | 2/23/2016 | 5/11/2016 | | PASS |
Carl Westfall
|
|
|
(1st done) 1401 W. IDAHO ST (OLD WATERCOOLER SITE) (Mar 22 - 25 days) - New
|
Routing - PLAN CHECK | 5/2/2016 | | 5/11/2016 | | PASS |
Carl Westfall
|
|
|
Location of van accessible parking spaces relative to accessible entrances was approved by Jason Blais, Building Official.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/11/2016 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 5/11/2016 | | DONE |
Christina Prado
|
|
|
As of 5/24/16, only ACHD is needed for issuance// C_P
Need ACHD, RP, GC Form & Revised Certificate of Value for issuance
|
Routing - Addressing | 5/2/2016 | | 5/3/2016 | | PASS |
Laura Hunter
|
|
|
Suite numbers transfered.
|
Routing - PLAN CHECK | 4/28/2016 | | 5/2/2016 | | FAIL |
Carl Westfall
|
|
|
The accessible parking space being on the shortest accessible route to accessible entrances has not been resolved.
|
Routing - Design Review | 5/2/2016 | | 5/2/2016 | | PASS |
Andrea Tuning
|
|
|
|
Plan resubmittals received | | | 4/28/2016 | | DONE |
|
|
|
|
Plan resubmittals requested | | | 4/26/2016 | | DONE |
|
|
|
|
Routing Off Site - STRUCTURAL | 4/19/2016 | | 4/26/2016 | | PASS |
Carl Westfall
|
|
|
Jared Bauder (CH2MHill)
|
Routing - PLANNING Land Div | 4/19/2016 | | 4/20/2016 | | PASS |
Todd Tucker
|
|
|
|
Routing PW Drainage | 4/19/2016 | | 4/20/2016 | | PASS |
Brian Murphy
|
|
|
|
Routing - PLANNING | 4/19/2016 | | 4/19/2016 | | PASS |
Cody Riddle
|
|
|
Parcels have been consolidated as required.
|
Routing - PLAN CHECK | 4/13/2016 | | 4/19/2016 | | FAIL |
Carl Westfall
|
|
|
Some items still not resolved.
|
Routing - Design Review | 4/19/2016 | | 4/19/2016 | | FAIL |
Andrea Tuning
|
|
|
The applicant is required to provide two accesible parking spaces. One is required to be van accessible.
|
Routing - Addressing | 4/19/2016 | | 4/19/2016 | | PASS |
Laura Hunter
|
|
|
|
Plan resubmittals received | | | 4/13/2016 | | DONE |
|
|
|
Plans Examiner was out sick after 12:00 Noon on the 13th (Wednesday) until Monday the 18th. The resubmittal came in at about 2:16 on the 13th. That's the reason it sat so long before being routed as well as about 20 sheets that were not given the correct file name for propert versioning.
|
Route to Impact Fee Review | 3/28/2016 | 3/31/2016 | 3/31/2016 | | PASS |
Cindy M. Gould
|
|
|
|
1st review completed | | | 3/28/2016 | | DONE |
|
|
|
|
Plan resubmittals requested | | | 3/28/2016 | | DONE |
|
|
|
|
Routing PW Sewer Rating | 2/24/2016 | | 3/28/2016 | | PASS |
Rachael Beierle
|
|
|
Was this review completed? CJW
|
Routing - PLAN CHECK | 2/23/2016 | | 3/19/2016 | | FAIL |
Carl Westfall
|
|
|
|
Routing Off Site - STRUCTURAL | 2/23/2016 | | 3/2/2016 | | FAIL |
Carl Westfall
|
|
|
Jared Bauder (CH2MHill)
|
Routing - Addressing | 2/23/2016 | | 3/2/2016 | | FAIL |
Laura Hunter
|
|
|
Parcels need consolidated.
|
Routing - PLUMBING | 2/23/2016 | | 3/1/2016 | | PASS |
Daryl Spivey
|
|
|
per plans and ISPC
|
Routing - MECHANICAL | 2/23/2016 | | 2/29/2016 | | PASS |
Troy James
|
|
|
|
Routing - FIRE | 2/23/2016 | 2/23/2016 | 2/26/2016 | | PASS |
Katie Marron
|
|
|
Attached comments to plans.
|
Routing PW Drainage | 2/24/2016 | | 2/25/2016 | | FAIL |
Brian Murphy
|
|
|
need o and m agreement
|
Routing PW Sewer Design | 2/24/2016 | | 2/25/2016 | | PASS |
Kyle S. Rosenmeyer
|
|
|
|
Routing PW Solid Waste | 2/24/2016 | | 2/25/2016 | | PASS |
Megan Durrell
|
|
|
|
Routing PW Geothermal | 2/24/2016 | | 2/24/2016 | | PASS |
Jon R. Gunnerson
|
|
|
Not connecting to geothermal heating district. JG 2/24/16
|
Routing - PUBLIC WORKS | 2/23/2016 | | 2/24/2016 | | PASS |
Rachael Beierle
|
|
|
|
Routing - Erosion and Sediment | 2/23/2016 | | 2/24/2016 | | PASS |
Evan Jenkins
|
|
|
(Site Prep Inspection and Approval Required Prior to Earth Disturbance)
**Project Management-Angie Brosious**1: 3-story, slab-on-grade, wood framed mixed-use structure with 7 live/work apartment units, 30 upper floor apartment units, and a small retail shell space on the corner. Project includes all related site work, landscaping and mechanical, plumbing and electrical work.
|
Routing - PLANNING | 2/23/2016 | | 2/24/2016 | | FAIL |
Cody Riddle
|
|
|
Site specific condition 2b from the conditional use permit required completion of a parcel consolidation prior to issuance. Emailed architect and owner today of the requirement. CER 2/24/16
|
Routing - PLANNING Land Div | 2/23/2016 | | 2/24/2016 | | FAIL |
Todd Tucker
|
|
|
The two parcels must be combined prior to issuance of a building permit.
|
Routing - Design Review | 2/23/2016 | | 2/24/2016 | | FAIL |
Andrea Tuning
|
|
|
The applicant did not submit:
bicycle parking plan showing 48 parking spaces.
transformers in appropriate locations.
cutsheets for all pedestrian scale light fixtures.
window details showing the required 2-inch reveal.
interior landscape planters that are 8-feet (measured inside of curb to inside of curb).
landscape plan.
mechanical screen details.
light poles in appropriate locations.
|
Pending Assignment by TLW | 2/23/2016 | | 2/23/2016 | | DONE |
Tim L. Woodard
|
|
|
|
Intake Approval | | | 2/17/2016 | | PASS |
|
|
|
|
Application received | | | 2/16/2016 | | DONE |
|
|
|
Application submitted via PDS Online on Feb 16 2016 5:32PM
|
First Notice | | 8/5/2017 | | | |
|
|
|
|