Permit Information
Permit NumberBLD16-00766
StatusFinaled
Name BENITON CONSTRUCTION
Site Address 12095 W USTICK RD
Project NameMaverik Boise 240
Customer Number 
ePlanReviewYes
Description
(MAVERIK - Store #240) Special Inspections Required see form 310. Permit to construct a new 5,518 square foot mercantile station, trash enclosure, trellis and fuel canopy. Special inspections per #310 form. All signs shall be reviewed under a separate permit. Scope of work to include all site work related to this project as shown on the approved drawings. Building shall include foundation, walls, roof construction and interior TI as shown on approved drawings. Interior finish material shall meet IBC chapter 8. All associated trade work for plumbing, mechanical and electrical shall obtain all required permits and inspections. This building is NOT fire sprinklered. **ajs**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Telephone call  4/26/2017 DONE
customer called-expressing a check for final fees due-should have it by May 1, 2017
Print Statement  4/20/2017 DONE
Print Statement  1/20/2017 DONE
Print Statement  1/20/2017 DONE
First Notice 12/22/20161/10/2017 DONE
sent in mail 1-11-2017
BLD-Final12/12/201612/12/201612/12/2016PPASS
DetailsJim Sly
Jam Phone #: ###-####
OK for Perm Occ.
Permanent Occupancy  12/12/2016 DONE
BLD-Final12/6/201612/6/201612/8/2016PPART
DetailsJim Sly
Beniton Phone #: ###-####
OK for Temp Occ. OK for Perm Occ. when.....2 separate exit doors at North side of Bldg have double keyed locks with indicators installed.
FIRE-Supply Line Hydro12/7/201612/8/201612/8/2016APASS
DetailsTroy Cobbley
Life safety passed
FIRE-Final Inspection12/6/201612/7/201612/7/2016APART
DetailsTroy Cobbley
A fire watch is to be inplace as per Fire Dept and the contractor discussion for tonight. I'm scheduled for a final re-inspection for tomorrow morning for the testing of the two duct smoke detectors. Jim Sly is going to cover the main exit door hardware. I need to verify with the Fire Dept that all items for their tank inspection have be addressed. All other items appear ok.
PubWorks Occupancy Approval12/7/201612/7/201612/7/2016 DONE
DetailsTiffany Lowery
PubWorks Occupancy Approval12/7/201612/7/201612/7/2016 DONE
DetailsTiffany Lowery
Zoning Approval12/6/201612/6/201612/6/2016 PASS
DetailsJosh Wilson
BLD-Ceiling Grid Inspection11/18/201611/21/201611/21/2016APASS
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Jan Tietjen
BLD-Energy code compliance10/20/201610/21/201610/21/2016PPASS
DetailsJim Sly
Jam Phone #: ###-####
BLD-Framing/Rough-in10/19/201610/19/201610/19/2016APASS
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Jan Tietjen
BLD-Energy code compliance10/4/201610/5/201610/5/2016APART
DetailsJim Sly
Jan Phone #: ###-####
Walls behind coolers ......OK.
BLD-Wall Bracing9/30/201610/3/201610/3/2016PPASS
DetailsJim Sly
Dan Phone #: ###-####
BLD-Conference9/26/20169/26/20169/26/2016PDONE
DetailsJim Sly
Jam Phone #: ###-####
Walk Thru with Jan........Strata hired to do all special inspections.Exterior walls and roof framing almost complete.....went over wall bracing.
BLD-Foundation8/22/20168/23/20168/23/2016PPASS
DetailsJim Storey
Janan Phone #: ###-#### placed w si
BLD-Foundation8/17/20168/18/20168/18/2016APEND
DetailsJim Sly
Late morning .......Rebar // Jay Phone #: ###-####
Inspection of Footings for entire building. STRATA will be doing all special inspections. OK to pour with approval from STRATA and Stamped Approved plans are on site. No approved planson site at this time.
BLD-Footing8/12/20168/15/20168/15/2016APASS
DetailsMike Jordan
Jan-rebar-pour time 2:30 Phone #: ###-####. column footings for canopy. Will have special inspection.
Issue PAID IN FULL permit  7/29/2016 DONE
Print Occupancy Form  7/29/2016  
OVERRIDE  7/8/2016  
Plan assigned to (AJS)4/6/20164/6/20167/8/2016 PASS
DetailsAdele J Schaffeld-Griffin
1st review completed New Maverik and Fuel Island
PLANS/APPL TAKEN TO FRONT DESK  7/8/2016 DONE
Permit Ready to Issue  7/8/2016 DONE
still needs; ACHD approval 7-11-16 /CEV

Still needs; ACHD approval, GC Form, Revised Cert of Value 7-8-16 /CEV

Needs; ACHD approval, RP, GC Form, Revised Cert of Value
Routing PW Drainage6/30/2016 7/7/2016 PASS
DetailsBrian Murphy
Routing Off Site - STRUCTURAL7/6/2016 7/6/2016 PASS
DetailsAdele J Schaffeld-Griffin
reviewed last 2 items
Routing PW Drainage5/20/2016 6/15/2016 FAIL
need o and agreement
Routing PW Sewer Design5/20/2016 5/31/2016 PASS
DetailsKyle S. Rosenmeyer
Routing Off Site - STRUCTURAL5/20/2016 5/31/2016 FAIL
DetailsAdele J Schaffeld-Griffin
Routing - PLAN CHECK5/20/2016 5/23/2016 PASS
DetailsAdele J Schaffeld-Griffin
Routing - PLUMBING5/23/2016 5/23/2016 PASS
DetailsDaryl Spivey
Provide 4 inch drain for 2 1/2 inch RPBP to drain to.
Routing - Design Review5/20/2016 5/20/2016 PASS
DetailsJosh Wilson
Route to Impact Fee Review5/5/20165/8/20165/5/2016 PASS
DetailsCindy M. Gould
1st review completed  5/5/2016 FAIL
DetailsAdele J Schaffeld-Griffin
Routing - PLAN CHECK4/6/2016 5/5/2016 FAIL
DetailsAdele J Schaffeld-Griffin
Routing - PLANNING Land Div4/6/2016 5/4/2016 PASS
DetailsTodd Tucker
Routing PW Environmental4/6/2016 5/4/2016 PASS
DetailsRick Christenson
Exterior Grease Interceptor 1500 gallon shown.
Routing Off Site - STRUCTURAL4/6/2016 4/18/2016 FAIL
DetailsAdele J Schaffeld-Griffin
Routing PW Drainage4/6/2016 4/18/2016 FAIL
DetailsBrian Murphy
NEEDS HYDRO CARBON TREATMENT ANA OM AGREEMENT
Routing - Design Review4/6/2016 4/13/2016 PASS
DetailsJosh Wilson
Routing - FIRE4/6/20164/6/20164/11/2016 PASS
DetailsKatie Marron
Comments attached to case.
Routing PW Solid Waste4/6/2016 4/11/2016 PASS
DetailsMegan Durrell
Routing - MECHANICAL4/6/2016 4/11/2016 PASS
DetailsTroy James
Routing - PLUMBING4/6/2016 4/8/2016 PASS
DetailsDaryl Spivey
1) additional cross connection protection may be required
2) asse 1070 mixing valves required at the lavs
3) floor sinks need to be 1/2 exposed at the cabinets
Routing PW Sewer Design4/6/2016 4/7/2016 FAIL
DetailsKyle S. Rosenmeyer
Install 48" sewer manhole labeled "401Y10" and connect 6" sewer service matching crown of pipe to crown of 8" sewer main. Show manhole angle between inverts. 6" service line within Boise Sewer Easement required to be 2% slope minimum.

Add note: Contact Boise Public Works 48 Hours prior to sewer connection to obtain tap permit and schedule inspection.
Routing PW Sewer Rating4/6/2016 4/7/2016 PASS
DetailsJennifer Bruner
Routing - Addressing4/6/2016 4/6/2016 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS4/6/2016 4/6/2016 PASS
DetailsJennifer Bruner
Routing - Erosion and Sediment4/6/2016 4/6/2016 PASS
DetailsEvan Jenkins
(Site Prep Inspection and Approval Required Prior to Earth Disturbance)

(MAVERIK - Store #240) Permit to construct a new 5,518 square foot gas station and fuel canopy. 16049 Maverik Boise 240 Gas Station and Fuel Pumps
Pending Assignment by TLW4/6/2016 4/6/2016 DONE
DetailsTim L. Woodard
Intake Approval  4/5/2016 PASS
DetailsTim L. Woodard
Intake Approval  3/30/2016 FAIL
3-20-16
Please provide interior and exterior lighting compliance reports.
Please provide a mechanical compliance report.
The compliance report should also indicate the additional energy efficiency package if completed using Com-Check
All reports are required to use the same standard Ashrae 90.1 or Com-Check.
Intake Approval  3/14/2016 FAIL
Upload the form 502 checlist with all required items
Application received  3/10/2016 DONE
Application submitted via PDS Online on Mar 10 2016 2:13PM