Information based on query as of Saturday, June 29, 2024.
Permit Information
Permit NumberBLD16-01552
StatusFinaled
Name BECK CONSTRUCTION INC
Site Address 3103 W CRESCENT RIM DR
Project Name 
Customer Number 
ePlanReviewNo
Description
***prev home to be demo'd by different contractor before this permit is issued***Permit for the construction of a new 3845 sq. ft., three story (first story 2506 sq. ft., second story 674 sq ft and the unfinished basement 665 sq. ft.) single family dwelling with 3 bedrooms, 2 full bathrooms & 2 half bathrooms, approximately 434 sq. ft. of covered patio’s/porches and 976 sq. ft. attached garage per the approved plans, plan review report, engineering and any notations. R-1C zoning and setbacks per planning. **BJM**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/18/20175/19/20175/19/2017APASS
DetailsDave Hannah
Blower door test results and image of spring loaded hinges texted to D. Hannah Phone #: ###-#### Inspection requested via web by Gary Beck
DOC - Permit Finaled5/19/20175/19/20175/19/2017PPASS
DetailsDave Hannah
BLD-Final5/17/20175/17/20175/18/2017PPEND
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Gary Beck needs energy cert final signoffs
Additional plans submitted  5/10/2017 DONE
Representative for adjacent parcel provided two copies of survey. Taken to Brian
** 5-10-17 - One copy put with filed plans, one copy given to records, uploaded pdf to Tidemark Documents - **BJM**
BLD-Energy code compliance11/4/201611/4/201611/4/2016PPASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Gary Beck
BLD-Wall cover11/4/201611/4/201611/4/2016PPASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Gary Beck
BLD-Framing/Rough-in9/29/20169/29/20169/29/2016PPART
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Gary Beck c/n on site ok to insulate
BLD-Wall Bracing7/28/20167/28/20167/28/2016PPASS
DetailsJim Sly
Shear wall inspection request Phone #: ###-#### Inspection requested via web by Gary Beck
BLD-Foundation6/10/20166/10/20166/10/2016PPASS
DetailsJim Sly
Request inspection around 2 Phone #: ###-#### Inspection requested via web by Ben Sears
BLD-Footing5/31/20166/1/20166/1/2016PPASS
DetailsDave Hannah
Request inspection around 3 Phone #: ###-#### Inspection requested via web by Ben Sears
Issue PAID IN FULL permit  5/24/2016 DONE
OVERRIDE  5/18/2016  
Plan assigned to (BJM)5/6/20165/6/20165/18/2016 DONE
DetailsBrian McGowan
due 5/18
1st review completed  5/18/2016 DONE
DetailsBrian McGowan
Case Summary (BLD)  5/18/2016 DONE
DetailsBrian McGowan
PLANS/APPL TAKEN TO FRONT DESK  5/18/2016 DONE
DetailsBrian McGowan
Permit Ready to Issue  5/18/2016 DONE
DEMO, BLD16-01578, needs final first.
Inspection Record Card- Bld  5/18/2016 DONE
Telephone call  5/18/2016 DONE
called Gary to let know permit is ready and what the fees are also that he has to have the demo final before he can pick this permit up
Routing - PLAN CHECK5/4/2016 5/18/2016 PASS
DetailsBrian McGowan
Plan assigned to (LEG) Tisha5/4/2016 5/6/2016 DEFR
DetailsTisha Gallop
Route to Impact Fee Review5/4/20165/7/20165/5/2016 PASS
DetailsCindy M. Gould
Routing - Addressing5/4/2016 5/4/2016 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS  5/4/2016 PASS
Routing - PLANNING5/4/2016 5/4/2016 PASS
DetailsSue Cummings
Driveway not to excede 33ft in fron or side street setback. requested the applicant to provide small map for Tidemark
Routing - MECHANICAL  5/4/2016 PASS
DetailsTroy James
Plans ACCEPTED BY PLAN TECH  5/4/2016 DONE
Intake Approval  5/4/2016 PASS
Recd Pcfee & Taken To Pln CK  5/4/2016 DONE
Application received 5/4/2016