Information based on query as of Saturday, June 29, 2024.
Permit Information
Permit NumberBLD16-01738
StatusFinaled
Name INVENTIVE RENOVATIONS LLC
Site Address 6565 W EMERALD ST
Project NameFMRI
Customer Number 
ePlanReviewYes
Description
(FMRI) //Plan Modification to construct select interior non-load bearing walls to create a slightly larger room #120, remove select portion of millwork at reception area #104, new door opening at room #149, new sinks at rooms #111 and 130, relocate sink at RX room #161. JG 7-27-2016 // Permit is to combine an existing 5,871 sq. ft. space and a 6,707 sq. ft. adjacent tenant space to create a new tenant space that is 12,488 sq. ft. and occupy the entire building. Approval is contingent upon adhering to the approved plans on file. Work includes: removal of select interior non-load bearing walls creating a larger exam room #111, #120 and creating a new RX room 161, construction of select interior non-load bearing walls to create a storage room #105 and wall infill at rooms #120, #111 and RX #161, continuation of select interior walls to the underside of roof deck at room #149 and RX #161, millwork, new sinks at rooms #131 and RX #161, select new suspended acoustic ceiling at room #111, relocate existing light fixture, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the 2012 IBC. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 8/20/20168/29/2016 DONE
This permit finaled on the web by Colby Peters
First Notice 8/8/20168/10/2016 DONE
mailed 8/11/16
BLD-Final7/26/20167/29/20167/29/2016APASS
DetailsMike Jordan
Colby Phone #: ###-####. Ok for perm occ. as per Mike J. no mech done or needed
FIRE-Final Inspection7/28/20167/29/20167/29/2016APASS
DetailsTroy Cobbley
life safety passed
Permanent Occupancy  7/29/2016 DONE
FIRE-Final Inspection7/26/20167/28/20167/28/2016PFAIL
DetailsTroy Cobbley
Repair the two emergency lights in the lobby and the exit sign over the main exit door.
FIRE-Conference7/26/20167/26/20167/27/2016PDONE
DetailsTroy Cobbley
I went over life safety requirements with the superintendant.
BLD-Conference7/26/20167/27/20167/27/2016ADONE
DetailsMike Jordan
Colby Phone #: ###-####
BLD-Framing/Rough-in6/24/20166/27/20166/27/2016APASS
DetailsMike Jordan
Colby Phone #: ###-####
BLD-Framing/Rough-in6/23/20166/23/20166/23/2016PNR
DetailsMike Jordan
Colby Phone #: ###-####. Provide the missing plan sheets.
Print Occupancy Form  5/31/2016 DONE
Issue PAID IN FULL permit  5/31/2016 DONE
Plan assigned to (JG)5/17/20165/17/20165/19/2016 PASS
DetailsJavier Guzman
5/23 L1 FMRI TI ePlan
Routing - PLAN CHECK5/17/2016 5/19/2016 PASS
DetailsJavier Guzman
Routing - Addressing5/17/2016 5/19/2016 PASS
DetailsLaura Hunter
1st review completed  5/19/2016 DONE
PLANS/APPL TAKEN TO FRONT DESK  5/19/2016 DONE
Permit Ready to Issue  5/19/2016 DONE
DetailsChristina Prado
Need GC Form & Resived Certificate of value prior to issuance
Routing - PUBLIC WORKS5/17/2016 5/17/2016 PASS
DetailsRachael Beierle
Intake Approval  5/17/2016 PASS
DetailsJavier Guzman
Application received  5/13/2016 DONE
Application submitted via PDS Online on May 13 2016 2:55PM