BLD-Final | 12/7/2016 | 12/9/2016 | 12/9/2016 | P | PASS |
Phil Shearer
|
|
|
Please Call prior to coming so I can be there... Thx Cinnamon Phone #: ###-#### Inspection requested via web by Jed Dilworth-would like you to go as late as possible
|
DOC - Permit Finaled | 12/9/2016 | 12/9/2016 | 12/9/2016 | P | PASS |
Phil Shearer
|
|
|
|
DOC - Permit Finaled | 12/9/2016 | 12/9/2016 | 12/9/2016 | P | PASS |
Phil Shearer
|
|
|
|
BLD-Final | 12/7/2016 | 12/8/2016 | 12/7/2016 | P | CANC |
Phil Shearer
|
|
|
Phil - please call prior to coming up so I can make sure I meet you there. thanks so much Cinnamon Phone #: ###-#### >> Inspection requested via web by Jed Dilworth Inspection cancelled from web by: Jed Dilworth
|
PubWorks Occupancy Approval | 12/7/2016 | 12/7/2016 | 12/7/2016 | | DONE |
Jason C. Taylor
|
|
|
A letter from the applicant’s civil engineer indicating that the final grading and drainage is acceptable has been received by Public Works. Final occupancy may be approved by the building department. Jason Taylor ###-####.
|
BLD-Other | 9/28/2016 | 9/28/2016 | 9/28/2016 | P | PASS |
Phil Shearer
|
|
|
cinnamon - soffit Phone #: ###-####
|
BLD-Other | 9/27/2016 | 9/27/2016 | 9/27/2016 | P | CANC |
Phil Shearer
|
|
|
This is for inspection on the patio area Thanks Cinnamon Dilworth Phone #: ###-#### >> Inspection requested via web by Jed Dilworth
|
BLD-Other | 9/26/2016 | 9/26/2016 | 9/26/2016 | A | FAIL |
Phil Shearer
|
|
|
This is for the inspection showing I have sheet rock in the sofffit. Thanks Cinnamon Dilworth Phone #: ###-#### Inspection requested via web by Jed Dilworth
|
BLD-Energy code compliance | 9/2/2016 | 9/8/2016 | 9/8/2016 | P | PASS |
Jim Sly
|
|
|
everything is on the fire place // cinnamen Phone #: ###-####
|
BLD-Framing/Rough-in | 9/1/2016 | 9/2/2016 | 9/2/2016 | P | PART |
Phil Shearer
|
|
|
Cinnamon Phone #: ###-####. Provide Engineered fix for t46 truss, missing hangers on j5 trusses, Fire blocking.
|
BLD-Wall Bracing | 8/8/2016 | 8/9/2016 | 8/9/2016 | A | PASS |
Jim Storey
|
|
|
I have the information in regards to the nailing pattern. If you call me when you are headed up that direction I will call the framer and let him know and we will meet you there. Thanks so much Phone #: ###-#### Inspection requested via web by Jed Dilworth
|
BLD-Wall Bracing | 8/5/2016 | 8/8/2016 | 8/8/2016 | A | FAIL |
Phil Shearer
|
|
|
Call Cinnamon ###-#### and I can meet you at the site. Phone #: ###-#### Inspection requested via web by Jed Dilworth
|
Inspection Record Card- Bld | | | 7/6/2016 | | DONE |
|
|
|
|
BLD-Foundation | 6/27/2016 | 6/28/2016 | 6/28/2016 | A | PASS |
Phil Shearer
|
|
|
Kevin-wall Phone #: ###-####
|
BLD-Footing | 6/23/2016 | 6/24/2016 | 6/24/2016 | P | PASS |
Phil Shearer
|
|
|
Keith Phone #: ###-####
|
PubWorks Subgrade Approval | 6/23/2016 | 6/23/2016 | 6/23/2016 | | DONE |
Jason C. Taylor
|
|
|
A letter from the applicant’s geotechnical engineer indicating that the footing subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Jason Taylor ###-####.
|
OVERRIDE | | | 6/7/2016 | | |
|
|
|
|
Plan assigned to (DAF) | 5/23/2016 | 5/23/2016 | 6/7/2016 | | DONE |
David Ferguson
|
|
|
due 6/7 L2 hillside - Plan Review complete - Troy needs to approve Manual J
|
Routing - MECHANICAL | 6/7/2016 | | 6/7/2016 | | PASS |
Troy James
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/7/2016 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 6/7/2016 | | DONE |
|
|
|
All Met
|
Inspection Record Card- Bld | | | 6/7/2016 | | DONE |
|
|
|
|
Telephone call | | | 6/7/2016 | | DONE |
|
|
|
called Jed- told Cinnamon that permit is ready and fees due
|
Issue PAID IN FULL permit | | | 6/7/2016 | | DONE |
|
|
|
|
Routing - MECHANICAL | 5/23/2016 | | 6/6/2016 | | FAIL |
Troy James
|
|
|
emailed 4 seasons
|
Routing - PLAN CHECK | 5/27/2016 | | 6/3/2016 | | PASS |
David Ferguson
|
|
|
|
1st review completed | | | 6/3/2016 | | DONE |
David Ferguson
|
|
|
|
Case Summary (BLD) | | | 6/3/2016 | | DONE |
David Ferguson
|
|
|
|
Routing - FIRE | 5/27/2016 | 5/17/2016 | 5/27/2016 | | PASS |
Scott Arellano
|
|
|
This home has been evaluated for FD vehicle access and defensible space. East Birdsong street is being constructed behind this structure.
|
Routing - Erosion and Sediment | | | 5/27/2016 | | PASS |
Andy J. Long
|
|
|
ESC site map and narrative approved. Valid RP and PD designated. ESC site preparation inspection required, call ###-####
|
Routing - PUBLIC WORKS | 5/19/2016 | | 5/23/2016 | | PASS |
Jennifer Bruner
|
|
|
|
Routing - PLANNING | 5/23/2016 | | 5/23/2016 | | PASS |
Brent Moore
|
|
|
|
Plan assigned to (LEG) Tisha | 5/17/2016 | | 5/23/2016 | | DEFR |
Tisha Gallop
|
|
|
|
Routing PW Grading-Hillside | 5/19/2016 | | 5/23/2016 | | PASS |
Jason C. Taylor
|
|
|
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at ###-####
Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at ###-####.
|
Routing PW Sewer Rating | 5/19/2016 | | 5/19/2016 | | PASS |
Jennifer Bruner
|
|
|
|
Routing - Addressing | 5/17/2016 | | 5/19/2016 | | PASS |
Laura Hunter
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 5/17/2016 | | DONE |
|
|
|
|
Intake Approval | | | 5/17/2016 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 5/17/2016 | | DONE |
|
|
|
|
Application received | | 5/17/2016 | | | |
|
|
|
|