BLD-Final | 11/15/2016 | 11/16/2016 | 11/16/2016 | A | PASS |
Jim Storey
|
|
|
|
DOC - Permit Finaled | 11/16/2016 | 11/16/2016 | 11/16/2016 | P | PASS |
Jim Storey
|
|
|
|
BLD-Final | 11/15/2016 | 11/15/2016 | 11/15/2016 | P | DEFR |
Jim Storey
|
|
|
Bill Phone #: ###-####
|
BLD-Energy code compliance | 9/30/2016 | 9/30/2016 | 9/30/2016 | P | PASS |
Phil Shearer
|
|
|
Bill Phone #: ###-####
|
BLD-Framing/Rough-in | 9/28/2016 | 9/28/2016 | 9/28/2016 | P | PASS |
Jim Storey
|
|
|
would like call ahead; bill Phone #: ###-####
|
BLD-Framing/Rough-in | 9/22/2016 | 9/22/2016 | 9/22/2016 | P | FAIL |
Jim Storey
|
|
|
Phil Phone #: ###-####CUTTING, NOTCHING AND DRILLING
R502.8.1 Sawn lumber. Notches in solid lumber joists, rafters and beams shall not exceed one-sixth of the depth of the member, shall not be longer than one-third of the depth of the member and shall not be located in the middle one-third of the span. Notches at the ends of the member shall not exceed one-fourth the depth of the member. The tension side of members 4 inches (102 mm) or greater in nominal thickness shall not be notched except at the ends of the members. The diameter of holes bored or cut into members shall not exceed one-third the depth of the member. Holes shall not be closer than 2 inches (51 mm) to the top or bottom of the member, or to any other hole located in the member. Where the member is also notched, the hole shall not be closer than 2 inches (51 mm) to the notch. truss engineering
|
BLD-Framing/Rough-in | 9/21/2016 | 9/21/2016 | 9/22/2016 | P | NR |
Jim Storey
|
|
|
Phil Phone #: ###-####
|
BLD-Framing/Rough-in | 9/20/2016 | 9/20/2016 | 9/20/2016 | P | NR |
Jim Storey
|
|
|
Bill Phone #: ###-####
|
BLD-Wall Bracing | 9/1/2016 | 9/2/2016 | 9/2/2016 | P | PASS |
Jim Storey
|
|
|
Bill Phone #: ###-####
|
BLD-Foundation | 7/29/2016 | 7/29/2016 | 7/29/2016 | P | PASS |
Phil Shearer
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 7/27/2016 | 7/28/2016 | 7/28/2016 | P | PASS |
Jim Storey
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
Place hold on job | 7/13/2016 | | 7/20/2016 | | DONE |
Candy A. Nichols
|
|
|
DO NOT ISSUE WITHOUT BLD16-02352, BLD16-02381 TO 02385
|
Issue PAID IN FULL permit | | | 7/20/2016 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 7/20/2016 | | DONE |
|
|
|
|
OVERRIDE | | | 7/13/2016 | | |
|
|
|
|
Permit Ready to Issue | | | 7/13/2016 | | DONE |
|
|
|
All requirements met
**All six project related BLD permits must be issued at the same time**
|
Plan assigned to (DAF) | 7/6/2016 | 7/6/2016 | 7/12/2016 | | DONE |
David Ferguson
|
|
|
due 7/12 - Plan review complete - Failed by Planning
|
Routing - PLANNING | 7/12/2016 | | 7/12/2016 | | PASS |
David Moser
|
|
|
The garage building complies with 5 foot setback
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/12/2016 | | DONE |
|
|
|
|
1st review completed | | | 7/8/2016 | | DONE |
David Ferguson
|
|
|
|
Routing - PLAN CHECK | 6/29/2016 | | 7/8/2016 | | PASS |
David Ferguson
|
|
|
|
Routing - MECHANICAL | 6/29/2016 | | 7/7/2016 | | PASS |
Troy James
|
|
|
|
Routing - PLANNING | 6/29/2016 | | 7/6/2016 | | FAIL |
David Moser
|
|
|
The Garage Bldg shall be setback 5 feet from property line.
|
Plan assigned to (LEG) Tisha | 6/29/2016 | | 7/6/2016 | | DEFR |
Tisha Gallop
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 6/29/2016 | | DONE |
|
|
|
|
Intake Approval | | | 6/29/2016 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 6/29/2016 | | DONE |
|
|
|
|
Routing - Addressing | 6/29/2016 | | 6/29/2016 | | PASS |
Laura Hunter
|
|
|
|
Routing - PUBLIC WORKS | 6/29/2016 | | 6/29/2016 | | PASS |
Rachael Beierle
|
|
|
|
Application received | | 6/29/2016 | | | |
|
|
|
|