Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberBLD16-02588
StatusFinaled
Name SYRINGA CONSTRUCTION LLC
Site Address 2626 N HEAVENS WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
WUI Zone A - Class A roof required** Permit for the construction of a new 3,322 sq. ft., one story single family dwelling with 5 bedrooms, 4 bathrooms, approximately 545 sq. ft. of covered patio/porch and a 1,099 sq. ft. attached garage per the approved plans, and any notations. A-1 zoning and setbacks per planning. **DAF**
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at 384-3946

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at 384-3946.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/15/20176/16/20176/16/2017APASS
DetailsTony Young
Garage access code is 0713 enter. Please call with any issues/questions.
Thanks,
Kim Phone #: ###-#### Inspection requested via web by Kim Winkle
DOC - Permit Finaled6/16/20176/16/20176/16/2017PPASS
DetailsTony Young
c of o issued
PubWorks Occupancy Approval6/15/20176/15/20176/15/2017 DONE
DetailsJason C. Taylor
A letter from the applicant’s designer indicating that the final grading and drainage is acceptable has been received by Public Works. Final occupancy may be approved by the building department. Jason Taylor ###-####.
BLD-Other3/27/20173/27/20173/27/2017PPASS
DetailsTony Young
Need an inspection of the Fire Treated T;G material we are installing on a house in a WUI zone. The material has been approved by Romeo. Wanted to check and see if we need the material checked before we stain ; install? Thanks Kim Phone #: ###-#### Inspection requested via web by Kim Winkle
BLD-Conference3/1/20173/2/20173/2/2017PPASS
DetailsTony Young
Need to have an Inspection on our 5/8" sheetrock soffits at 2626 N Heavens way -- only one layer needed because soffit material will be cement board.
Thanks! Phone #: ###-#### Inspection requested via web by Kim Winkle,, base layer of sheet rock ok on soffit areas,, patios/porches will be alternate method
BLD-Energy code compliance2/6/20172/7/20172/7/2017APART
DetailsTony Young
Thank you! Phone #: ###-#### Inspection requested via web by Kim Winkle,, ok to cover interior,, still need sofit inspection
BLD-Framing/Rough-in1/25/20171/26/20171/26/2017PFAIL
DetailsMike Jordan
Thank you! Phone #: ###-#### Inspection requested via web by Kim Winkle. NAil off all simpson hangars, fireblock al fur downs around showers and concealed areas either side of 3rd garage bay at ceiling level. Ok to insualte.
BLD-Conference12/19/201612/19/201612/19/2016PPART
DetailsTony Young
Hi, need to schedule a meeting to review a ventless roof application before we proceed with needed foam application. Please call either Steve @ ###-#### or Mike @ ###-#### to schedule. Thanks Phone #: ###-#### Inspection requested via web by Kim Winkle// ok to apply spray foam on the underside of the roof deck
BLD-Wall Bracing12/14/201612/15/201612/15/2016PPART
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Kim Winkle,, exterior shear ok
BLD-Foundation11/7/201611/7/201611/8/2016PDONE
DetailsTony Young
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
BLD-Footing11/3/201611/4/201611/4/2016APASS
DetailsTony Young
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
BLD-Footing11/2/201611/3/201611/3/2016PNR
DetailsDave Hannah
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
PubWorks Subgrade Approval10/31/201610/31/201611/2/2016 DONE
DetailsJason C. Taylor
**ENTIRE FOOTPRINT OF BUILDING INCLUDING ISOLATED EXTRIOR PADS***A letter from the applicant’s geotechnical engineer indicating that the footing subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Jason Taylor ###-####.
BLD-Footing10/30/201610/31/201610/31/2016PNR
DetailsTony Young
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
BLD-Footing10/30/201610/31/201610/30/2016ACANC
DetailsTony Young
Phone #: 2086971241 >> Inspection requested via mobile web by Heron Inspection cancelled via mobile web on Sunday, October 30, 2016.
BLD-Other10/6/201610/7/201610/7/2016APASS
DetailsJim Sly
Erosion control BMP inspection. Please call steve with any questions or concerns, 850.8424. All improvements should be done. Thank you, steve Phone #: ###-#### Inspection
requested via web by steve hanson
GOOD JOB!

BLD-Other10/4/201610/5/201610/5/2016AFAIL
DetailsJim Sly
Site ready for EROSION CONTROL INSPECTION. Please call Steve for questions/comments/timing to arrive on site and i will meet you there. Thanks! Phone #: 208-850
-8424 Inspection requested via web by steve
hanson
Correction notice posted. Old waddles not effective. Re-do Re-configure add more......as required. some older riffs are actually going underneath waddles. remove sediment buildup behind waddles. Prevent sediment from reaching storm drain lid and holes......protect drain. Clean out (2) existing drain inlet filters. Install silt fence per MFGs installation instructions.
Issue PAID IN FULL permit  10/4/2016 DONE
Inspection Record Card- Bld  10/4/2016 DONE
OVERRIDE  10/3/2016  
Plan assigned to (DAF)9/7/20169/7/201610/3/2016 DONE
DetailsDavid Ferguson
due 9/26 - Plan review complete - need addtl. WUI details and Hillside has failed too
Inspection Record Card- Bld  10/3/2016 DONE
Telephone call  10/3/2016 DONE
called Steve- left message that permit is ready and fees due
Routing - PLAN CHECK9/27/2016 10/3/2016 PASS
DetailsDavid Ferguson
Plan resubmittals received  10/3/2016 DONE
received two copies of sheet 6- gave to Dave
Case Summary (BLD)  10/3/2016 DONE
DetailsDavid Ferguson
PLANS/APPL TAKEN TO FRONT DESK  10/3/2016 DONE
Permit Ready to Issue  10/3/2016 DONE
Routing - PUBLIC WORKS9/29/2016 9/29/2016 PASS
DetailsMorgan Webb
Routing PW Grading-Hillside9/28/2016 9/28/2016 PASS
DetailsJason C. Taylor

A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at ###-####

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at ###-####.
Plan resubmittals received  9/27/2016 DONE
received (3) copies of materials testing & inspection reports
Routing PW Grading-Hillside9/23/2016 9/26/2016 FAIL
DetailsJason C. Taylor
1. Submit 3 copies of ALL the geotechnical reports, update letters, and reliance letters. I cannot process this application without these reports/letters.See the blurb from my approval letter for the P&Z application.

“The geotechnical investigation (by Materials Testing & Inspection dated April 15, 2015 (Submitted), Reliance Letter dated August 12, 2016 (NOT SUBMITTED), and Warranty Conditions confirmation email dated August 17, 2016 (NOT SUBMITTED))”.
Plan resubmittals received  9/26/2016 DONE
Two copies of pg 6 taken to dave f
Routing - PLAN CHECK9/14/2016 9/22/2016 FAIL
DetailsDavid Ferguson
1st review completed  9/22/2016 FAIL
DetailsDavid Ferguson
Plan resubmittals received  9/22/2016 DONE
received revised engineering and grading plans
Routing - FIRE9/14/2016 9/14/2016 PASS
DetailsScott Arellano
No comments attached to case. This structure has been evaluated for fire department vehicle access and WUI defensible space.
Routing - PLANNING9/9/2016 9/14/2016 PASS
DetailsLeon Letson
Routing - MECHANICAL  9/14/2016 PASS
DetailsTroy James
Routing - Erosion and Sediment9/14/2016 9/14/2016 PASS
DetailsEvan Jenkins
(Site Prep Inspection and Approval Required Prior to Earth Disturbance)

Permit for the construction of a new 3,322 sq. ft., one story single family dwelling with 5 bedrooms, 4 bathrooms, approximately ???? sq. ft. of covered patio/porch and a 1,099 sq. ft. attached garage
Routing PW Grading-Hillside9/8/2016 9/9/2016 FAIL
DetailsJason C. Taylor
1. Submit 3 copies of ALL the geotechnical reports, update letters, and reliance letters. I cannot process this application without these reports/letters.
2. Update grading plan as requested in Hillside approval. There are several items still missing or unclear. Call for details.
3. Update Structural engineering for tall wall. Structural engineering has a 6’ 8” wall and grading plan has 6’. A 6’ 8” section will not be approved.
Routing - PUBLIC WORKS9/9/2016 9/9/2016 FAIL
DetailsRachael Beierle
SEE HILLSIDE
Routing - Addressing9/7/2016 9/8/2016 PASS
DetailsLaura Hunter
Routing PW Sewer Rating9/8/2016 9/8/2016 PASS
DetailsRachael Beierle
Plans ACCEPTED BY PLAN TECH  9/7/2016 DONE
Intake Approval  9/7/2016 PASS
Recd Pcfee & Taken To Pln CK  9/7/2016 DONE
Plan assigned to (LEG) Tisha9/7/2016 9/7/2016 DEFR
DetailsTisha Gallop
Application received 7/14/2016