Permit Information
Permit NumberBLD16-02659
StatusFinaled
Name RMH COMPANY
Site Address 1161 W RIVER ST Unit: 130
Project NameMountain Waterworks -Suite 130
Customer Number 
ePlanReviewYes
Description
**(MOUNTAIN WATERWORKS – FIRST FLOOR - SUITE 130)** Permit is to remodel an existing 4,282 sq. ft. tenant space on the 1st floor of a 48,000 sq. ft. three story building. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select door/door frames, removal of select millwork, construction of select interior nonbearing walls to create a larger conference room, (4) offices, (3) offices with partial height walls, partial height walls at the open office area, a break room, new select transom windows, new millwork, relocate existing sink, relocating select existing light fixtures, adding select new light fixtures, some plumbing work, electrical work and interior finishes to be in compliance with Ch. 8 of the 2012 IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 11/20/201612/8/2016 DONE
This permit finaled on the web by Amy Wray
Second Notice 10/20/201611/15/2016 DONE
Mailed 11-16-16
First Notice 10/2/201610/10/2016 DONE
mailed 10-11-16
BLD-Final9/20/20169/21/20169/22/2016PPASS
DetailsDave Hannah
Doug Phone #: ###-####
Permanent Occupancy  9/22/2016 DONE
FIRE-Final Inspection9/20/20169/21/20169/21/2016APASS
DetailsJim Page
Fire sprinkler inspection for area of work complete, no modifications to fire alarm system, fire extinguisher will be mounted in discussed location. Final life fire safety inspection passed/complete.
BLD-Framing/Rough-in8/4/20168/8/20168/9/2016PPASS
DetailsDave Hannah
Doug Phone #: ###-####
Print Occupancy Form  8/1/2016 DONE
Issue PAID IN FULL permit  8/1/2016 DONE
Plan assigned to (JG)7/25/20167/25/20167/28/2016 PASS
DetailsJavier Guzman
1st review completed, 7/29 L1 Mountain Waterworks, ePlan
Routing - PLAN CHECK7/28/2016 7/28/2016 PASS
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  7/28/2016 DONE
Permit Ready to Issue  7/28/2016 DONE
Need GC Form and Revised Cert of Value
Routing - PLAN CHECK7/25/2016 7/26/2016 FAIL
DetailsJavier Guzman
ePlan
1st review completed  7/26/2016 FAIL
DetailsJavier Guzman
Routing - Addressing7/25/2016 7/25/2016 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS7/25/2016 7/25/2016 PASS
DetailsRachael Beierle
Intake Approval  7/25/2016 PASS
DetailsDavid Ferguson
Application received  7/20/2016 DONE
Application submitted via PDS Online on Jul 20 2016 11:11AM