BLD-Final | 2/8/2017 | 2/8/2017 | 2/8/2017 | P | PASS |
Mike Jordan
|
|
|
Brett Phone #: ###-####
|
DOC - Permit Finaled | 2/8/2017 | 2/8/2017 | 2/8/2017 | P | PASS |
Mike Jordan
|
|
|
|
Elevation Cert Rec'd-Final | | | 2/8/2017 | | DONE |
|
|
|
Final elevation certificate recieved. Jason Taylor ###-####
|
BLD-Energy code compliance | 12/14/2016 | 12/15/2016 | 12/15/2016 | P | PASS |
Mike Jordan
|
|
|
Insulation // Joel Phone #: ###-####
|
BLD-Framing/Rough-in | 12/14/2016 | 12/15/2016 | 12/15/2016 | A | PASS |
Mike Jordan
|
|
|
Joel Phone #: ###-####
|
BLD-Framing/Rough-in | 12/13/2016 | 12/14/2016 | 12/14/2016 | A | CANC |
Mike Jordan
|
|
|
joel Phone #: ###-####
|
BLD-Conference | 12/14/2016 | 12/14/2016 | 12/14/2016 | A | DONE |
Mike Jordan
|
|
|
joel Phone #: ###-####
|
BLD-Framing/Rough-in | 12/12/2016 | 12/13/2016 | 12/13/2016 | A | FAIL |
Mike Jordan
|
|
|
joel Phone #: ###-####. Complete lateral bracing on G3 truss. Provide continous bearingon G6 truss as shown on the truss engineering. Complete the fullheight blocking at B1,B2 and B3 areas as shown on the engineering. Install all straps on drag trusses as shown on engineering. Fasten gable to shear wall as shown on engineering. Correction notice posted. Ok to insulate.
|
Override - Condition Holds | 12/13/2016 | 1/1/1900 | 12/13/2016 | | |
|
|
|
frame
|
BLD-Framing/Rough-in | 12/12/2016 | 12/12/2016 | 12/12/2016 | P | FAIL |
Mike Jordan
|
|
|
joel Phone #: ###-####. Provide the truss enginnering and the additional enginnering. Ok to insulate. Correction notice posted.
|
Override - Condition Holds | 12/12/2016 | 1/1/1900 | 12/12/2016 | | |
|
|
|
frame
|
Override - Condition Holds | 12/12/2016 | 1/1/1900 | 12/12/2016 | | |
|
|
|
frame
|
Elevation Cert Rec'd-Midconst | | | 12/5/2016 | | DONE |
|
|
|
Received Elevation Certificate for "Building Under Construction". Okay to schedule a framing inspection.
Jim Wyllie / ###-####
|
BLD-Wall Bracing | 11/30/2016 | 12/1/2016 | 12/1/2016 | P | PASS |
Mike Jordan
|
|
|
Brett Phone #: ###-####
|
Override - Condition Holds | 11/30/2016 | 1/1/1900 | 11/30/2016 | | |
|
|
|
have not had frame yet
|
Plan Modification Accepted | | | 11/29/2016 | | DONE |
|
|
|
new manual j report
|
Routing - MECHANICAL | 11/29/2016 | | 11/29/2016 | | PASS |
Troy James
|
|
|
resubmitted manual j report
|
BLD-Footing | 11/16/2016 | 11/16/2016 | 11/16/2016 | P | PASS |
Mike Jordan
|
|
|
slab on grade, interior footing - Joel Phone #: ###-####
|
Override - Condition Holds | 11/16/2016 | 1/1/1900 | 11/16/2016 | | |
|
|
|
footing only
|
BLD-Foundation | 11/4/2016 | 11/7/2016 | 11/7/2016 | P | PASS |
Mike Jordan
|
|
|
Dane Phone #: ###-####
|
BLD-Footing | 11/3/2016 | 11/4/2016 | 11/4/2016 | P | PART |
Mike Jordan
|
|
|
Dane Phone #: ###-####
|
Override - Condition Holds | 11/3/2016 | 1/1/1900 | 11/3/2016 | | |
|
|
|
not the frame
|
PLANS/APPL TAKEN TO FRONT DESK | | | 9/26/2016 | | DONE |
|
|
|
plan modification, no fee due
|
CHANGE STATUS TO (ISS) | | | 9/26/2016 | | DONE |
|
|
|
|
Plan assigned to (LEG) Tisha | 9/22/2016 | | 9/26/2016 | | PASS |
Tisha Gallop
|
|
|
|
Routing - PLAN CHECK | 9/22/2016 | | 9/26/2016 | | PASS |
Tisha Gallop
|
|
|
plan modification to change girder point loads and add interior thickened slab footing for interior bearing wall
|
OVERRIDE | | | 9/23/2016 | | |
|
|
|
|
Override - Condition Holds | | | 9/23/2016 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 9/23/2016 | | DONE |
|
|
|
|
Override - Condition Holds | | | 9/23/2016 | | |
|
|
|
|
Permit Ready to Issue | | | 9/23/2016 | | DONE |
|
|
|
|
Plan Modification Accepted | | | 9/22/2016 | | DONE |
|
|
|
Modification to change from foundation to slab on grade construction
|
Override - Condition Holds | | | 9/21/2016 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 9/21/2016 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 9/21/2016 | | DONE |
|
|
|
|
CHANGE ISSUED DATE | | | 9/21/2016 | | |
|
|
|
permit issued twice in error
|
Elevation Cert Rec'd-Prelim | | | 9/12/2016 | | |
|
|
|
|
Elevation Cert Rec'd-Prelim | | | 9/12/2016 | | PASS |
|
|
|
|
OVERRIDE | | | 9/9/2016 | | |
|
|
|
|
Elevation Cert Rec'd-Prelim | | | 9/9/2016 | | DONE |
Jim Wyllie
|
|
|
per Jim Wylie
|
Plan resubmittals received | | | 9/9/2016 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 9/9/2016 | | 9/9/2016 | | PASS |
Tisha Gallop
|
|
|
|
Routing PW Flood Plain | 9/9/2016 | | 9/9/2016 | | PASS |
Jim Wyllie
|
|
|
per eplan
|
PLANS/APPL TAKEN TO FRONT DESK | | | 9/9/2016 | | DONE |
|
|
|
|
Override - Condition Holds | | | 9/9/2016 | | |
|
|
|
|
Permit Ready to Issue | | | 9/9/2016 | | DONE |
|
|
|
Needs additional Elevation Certificates submitted to Public Works Floodplain Coordinator prior to scheduling framing inspection and final occupancy requests. Per Tisha's hold in conditions
|
Plan assigned to (LEG) Tisha | 7/25/2016 | | 9/9/2016 | | DONE |
Tisha Gallop
|
|
|
1st review 8/4; plan check, floodplain
|
Routing - PLAN CHECK | 7/25/2016 | | 8/4/2016 | | FAIL |
Tisha Gallop
|
|
|
|
1st review completed | | | 8/4/2016 | | DONE |
|
|
|
pending approval by PW floodplain and Plan Check
|
Routing - MECHANICAL | 7/25/2016 | | 7/29/2016 | | PASS |
Troy James
|
|
|
|
Routing - PLANNING | 7/25/2016 | | 7/26/2016 | | PASS |
Jeff Lowe
|
|
|
|
Routing - Addressing | 7/25/2016 | | 7/26/2016 | | PASS |
Laura Hunter
|
|
|
|
Routing PW Flood Plain | 7/26/2016 | | 7/26/2016 | | FAIL |
Jim Wyllie
|
|
|
Elevation Certificate is required. Jim Wyllie / ###-####
|
Plans ACCEPTED BY PLAN TECH | | | 7/25/2016 | | DONE |
|
|
|
|
Intake Approval | | | 7/25/2016 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 7/25/2016 | | DONE |
|
|
|
|
Routing - PUBLIC WORKS | 7/25/2016 | | 7/25/2016 | | PASS |
Rachael Beierle
|
|
|
|
Application received | | | 7/22/2016 | | DONE |
|
|
|
Application submitted via PDS Online on Jul 22 2016 1:55PM
|