BLD-Final | 1/9/2017 | 1/10/2017 | 1/11/2017 | A | PASS |
Jim Sly
|
|
|
Garage code for access is 0713. Thanks Phone #: ###-#### Inspection requested via web by Kim Winkle
|
DOC - Permit Finaled | 1/10/2017 | 1/10/2017 | 1/10/2017 | P | PASS |
Jim Sly
|
|
|
|
BLD-Wall Bracing | 10/4/2016 | 10/5/2016 | 10/5/2016 | A | PASS |
Jim Sly
|
|
|
Drywall shear panel/screw pattern inspection. Approved plan on site. Please call Steve with questions or comments, 850.8424. thanks, steve Phone #: ###-#### Inspection requested via web by steve hanson
|
BLD-Energy code compliance | 9/27/2016 | 9/29/2016 | 9/29/2016 | A | PASS |
Tony Young
|
|
|
Framing final and energy inspection. Plans are onsite near power panel. Please call Steve with any questions; ###-####. Thank you, steve Phone #: ###-#### Inspection requested via web by steve hanson
|
BLD-Framing/Rough-in | 9/22/2016 | 9/26/2016 | 9/26/2016 | P | PART |
Tony Young
|
|
|
Home ready for framing inspection. Please call with any questions. Approved plan near electrical box in garage. Thank you, steve Phone #: ###-#### Inspection requested via web by steve hanson,,/// ok to insulate,, look for the purple paint marks for corrections,, point loads,, top plate straps,, gable bracing,, draft/fire blocking at the fireplace chase,, firewall between the house and garage in the attic (can be done later), etc
|
BLD-Wall Bracing | 9/15/2016 | 9/16/2016 | 9/16/2016 | A | PASS |
Jim Storey
|
|
|
Phone #: ###-#### Inspection requested via web by Kim Winkle
|
BLD-Foundation | 8/15/2016 | 8/15/2016 | 8/15/2016 | P | DONE |
Tony Young
|
|
|
Steve-wall Phone #: ###-####
|
BLD-Footing | 8/11/2016 | 8/12/2016 | 8/12/2016 | A | PASS |
Dave Hannah
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
OVERRIDE | | | 8/11/2016 | | |
|
|
|
|
Plan assigned to (BJM) | 7/27/2016 | 7/27/2016 | 8/11/2016 | | DONE |
Brian McGowan
|
|
|
Due 8-8
|
Case Summary (BLD) | | | 8/11/2016 | | DONE |
Brian McGowan
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/11/2016 | | DONE |
Brian McGowan
|
|
|
|
Permit Ready to Issue | | | 8/11/2016 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 8/11/2016 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 8/11/2016 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 8/1/2016 | | 8/11/2016 | | PASS |
Brian McGowan
|
|
|
|
Plan resubmittals received | | | 8/5/2016 | | DONE |
|
|
|
One copy of Lateral Calculations, Three copies of sheets A-1.1, A-1.2, A-1.3, A-1.4, A-1.5, A-1.6, A-1.7, A-1.8, A-1.9, A-1.10, A-1.11, A-1.12, A-1.13, A-1.14, A-1.15 and A-1.16. Taken to Brian Mc
|
1st review completed | | | 8/4/2016 | | FAIL |
Brian McGowan
|
|
|
|
Routing - MECHANICAL | 7/28/2016 | | 8/1/2016 | | PASS |
Troy James
|
|
|
|
Routing - PLANNING | 7/27/2016 | | 7/28/2016 | | PASS |
Colleen T Carroll
|
|
|
|
Plan assigned to (LEG) Tisha | 7/26/2016 | | 7/27/2016 | | DEFR |
Tisha Gallop
|
|
|
|
Routing - Addressing | 7/26/2016 | | 7/27/2016 | | PASS |
Laura Hunter
|
|
|
|
Routing - PUBLIC WORKS | | | 7/27/2016 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 7/26/2016 | | DONE |
|
|
|
|
Intake Approval | | | 7/26/2016 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 7/26/2016 | | DONE |
|
|
|
|
Application received | | 7/26/2016 | | | |
|
|
|
|