Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD16-02792
StatusExpired
Name TALBOY CONSTRUCTION
Site Address 12397 W FAIRVIEW AVE
Project NameMaverick Car Company
Customer Number 
ePlanReviewNo
Description
(MAVERICK CAR COMPANY – House Conversion) Permit is to remodel an existing 824 sq. ft. single family home to become a car dealership office. Approval is contingent upon adhering to the approved plans on file and attached engineering. Work includes: removal of select door/door frames, construction of a new entrance ADA accessible ramp, ADA accessible restroom, infill of select existing interior wall openings, new select gypsum ceiling, select new door/door frames, engineered repairs of fire damaged trusses, new light fixtures, electrical work, plumbing work, mechanical work and interior finishes to be in compliance with Ch. 8 of the 2012 IBC. This building is not Fire Sprinklered. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Permit EXPIRED  11/2/2017 DONE
DetailsChristina Prado
Tenant Improvement portion completed under BLD16-02889. See BLD16-02889 for final CO, inspection records and floor plan details
BLD-Aging Inspection7/11/20177/11/20177/12/2017 DONE
DetailsMike Jordan
Work in progress almost completed.
BLD-Aging Inspection7/12/20177/12/20177/12/2017 PEND
DetailsMike Jordan
Noted that new building is nearly completed.
BLD-Other3/1/20173/1/20173/1/2017APEND
DetailsMike Jordan
Will be vacated when new adjacent structure completed under bld16-02889.
Issue PAID IN FULL permit  8/26/2016 DONE
Plan assigned to (JG)8/4/20168/4/20168/23/2016 PASS
DetailsJavier Guzman
8/25 L3 MAVERICK CAR COMPANY Paper, pending Fire for 1st rev
Routing - PLAN CHECK8/22/2016 8/23/2016 PASS
DetailsJavier Guzman
Case Summary (BLD)  8/23/2016 DONE
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  8/23/2016 DONE
Permit Ready to Issue  8/23/2016 DONE
All Met
Inspector's copy Bld permit  8/23/2016 DONE
Print Occupancy Form  8/23/2016 DONE
Telephone call  8/23/2016 DONE
called GC- let him know permit is ready and fees due
1st review completed  8/22/2016 PASS
Routing - FIRE8/22/2016 8/22/2016 PASS
DetailsScott Arellano
Attached plan review comments to plans.
Routing - PLAN CHECK8/20/2016 8/20/2016 PASS
DetailsJavier Guzman
Routing - Erosion and Sediment8/4/2016 8/5/2016 CANC
DetailsAndy J. Long
No review or ESC permit required per scope of work. Repair to existing building with fire damage and installation of ramp. Minimal earth disturbance, low risk site.
Routing - Design Review8/4/2016 8/4/2016 PASS
DetailsSarah Schafer
Routing - Addressing8/4/2016 8/4/2016 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS8/4/2016 8/4/2016 PASS
DetailsRachael Beierle
NO SEWER AVAILABLE AT THIS TIME. SEPTIC USAGE ONLY.
Plans ACCEPTED BY PLAN TECH  7/29/2016 DONE
Intake Approval  7/29/2016 PASS
DetailsTim L. Woodard
as per Tim W no off site engineering needed-took to Tim W
Recd Pcfee & Taken To Pln CK  7/29/2016 DONE
Application received 7/29/2016