Print Statement | | | 7/5/2017 | | DONE |
|
|
|
|
First Notice | 5/19/2017 | 5/19/2017 | 6/14/2017 | | DONE |
Candy A. Nichols
|
|
|
sent in mail 6-14-17 pdf
|
BLD-Aging Inspection | 5/18/2017 | 5/18/2017 | 5/19/2017 | | DONE |
Tony Young
|
|
|
|
BLD-Aging Inspection | 5/17/2017 | 5/17/2017 | 5/19/2017 | | PASS |
Tony Young
|
|
|
|
DOC - Permit Finaled | 5/19/2017 | 5/19/2017 | 5/19/2017 | P | PASS |
Tony Young
|
|
|
|
Letter of compliance/Occupancy | | | 1/4/2017 | | DONE |
|
|
|
|
BLD-Final | 12/30/2016 | 1/3/2017 | 1/3/2017 | A | PASS |
Tony Young
|
|
|
Greg Phone #: ###-####
|
FIRE-Final Inspection | 12/30/2016 | 12/30/2016 | 12/30/2016 | A | PASS |
Jim Page
|
|
|
Final fire sprinkler inspection complete (FIR permit was not attached to this project, fire sprinkler work completed under FIR16-00782), final fire alarm inspection complete, fire extinguisher is in place with current inspection tag. Final life fire safety inspection passed/complete.
|
BLD-Final | 12/13/2016 | 12/14/2016 | 12/14/2016 | A | CANC |
Tony Young
|
|
|
Greg Phone #: ###-####
|
FIRE-Final Inspection | 12/13/2016 | 12/13/2016 | 12/13/2016 | P | CANC |
Jim Page
|
|
|
This inspection request will not be completed until the fire alarm issues with FIR16-00086 are resolved, this inspection request is cancelled.
|
BLD-Ceiling Grid Inspection | 12/7/2016 | 12/8/2016 | 12/8/2016 | A | PART |
Mike Jordan
|
|
|
Greg Phone #: ###-####. Needs to pull a fire sprinkler permit.
|
BLD-Framing/Rough-in | 10/27/2016 | 10/28/2016 | 10/28/2016 | A | PASS |
Jim Storey
|
|
|
Greg Phone #: ###-#### half walls and securty rm and adjasant rm walls ok to cover // rated west wall w fd needs arch. to justify drawnings to planreview
|
Issue PAID IN FULL permit | | | 9/29/2016 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 9/29/2016 | | DONE |
|
|
|
|
Plan assigned to (AJS) | 8/18/2016 | 8/18/2016 | 9/16/2016 | | PASS |
Adele J Schaffeld-Griffin
|
|
|
1st review completed
|
Routing - PLAN CHECK | 8/18/2016 | | 9/16/2016 | | PASS |
Adele J Schaffeld-Griffin
|
|
|
|
Routing - Design Review | 9/16/2016 | | 9/16/2016 | | PASS |
Josh Wilson
|
|
|
Ok- work interior to building.
|
1st review completed | | | 9/16/2016 | | DONE |
Adele J Schaffeld-Griffin
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 9/16/2016 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 9/16/2016 | | DONE |
|
|
|
** All requirements met 9-20-16 KRS***need GC & Rev Cert of val
|
Routing - MECHANICAL | 8/18/2016 | | 8/23/2016 | | PASS |
Troy James
|
|
|
|
Routing - PUBLIC WORKS | 8/18/2016 | | 8/19/2016 | | PASS |
Rachael Beierle
|
|
|
|
Routing - FIRE | 8/18/2016 | 8/18/2016 | 8/18/2016 | | PASS |
Katie Marron
|
|
|
Comments attached to case.
|
Intake Approval | | | 8/18/2016 | | PASS |
Javier Guzman
|
|
|
|
Routing - Addressing | 8/18/2016 | | 8/18/2016 | | PASS |
Laura Hunter
|
|
|
|
Application received | | | 8/15/2016 | | DONE |
|
|
|
Application submitted via PDS Online on Aug 15 2016 8:01AM
|
Intake Approval | | | 8/15/2016 | | FAIL |
Javier Guzman
|
|
|
Please provide and upload the following, Incomplete submittals will not be accepted:
1. Site specific fire flow at hydrants letter from Suez Water or other public water provider. Include static pressure if sprinklers are to be installed.
2. Code Analysis/Building Data on front sheet of plans which includes: code year, occupancy group(s), land use zone, construction type, tenant area, fire suppression system (specify NFPA code applicable), declare any fire alarm or smoke control system
|