Permit to add approx. 440 square feet of Living space ; adding Mud Room, Game Room, Bedroom and (approx. 1036 sq ft) of three car garage. No plumbing is proposed. New Living space is proposed to be heated by a ductless heating unit. All walls are 2x6 at 16"o.c. Proposed Prescriptive Energy Code to be used. Smoke detectors and carbon monoxide alarms are to be updated as required for all floors and new addition. All work to be done according to plans, notes, review notes and local codes. **BJM**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/21/20179/22/20179/22/2017APASS
DetailsJim Sly
Brad Phone #: ###-####
DOC - Permit Finaled9/22/20179/22/20179/22/2017PPASS
DetailsJim Sly
DOC - Permit Finaled9/22/20179/22/20179/22/2017PPASS
DetailsJim Sly
BLD-Final6/12/20176/13/20176/13/2017ANR
DetailsJim Sly
Brad Phone #: ###-####
C/N on site......Partial only......Could not contact Contr. wrong contact #
BLD - Request for Extension6/8/20176/8/20176/8/2017PPASS
DetailsDave Hannah
Brad Phone #: ###-####
BLD-Energy code compliance11/21/201611/23/201611/23/2016APASS
DetailsMike Jordan
Brad Phone #: ###-####
BLD-Framing/Rough-in11/23/201611/23/201611/23/2016APASS
DetailsMike Jordan
Brad Phone #: ###-####
BLD-Framing/Rough-in11/18/201611/21/201611/21/2016PFAIL
DetailsMike Jordan
Brad Phone #: ###-####. Provide straps for portal frame, interior side at header, egress window in bedroom at 48 inches. ok to insulate.
BLD-Wall Bracing11/8/201611/8/201611/8/2016PPASS
DetailsMike Jordan
Brian-brace wall panel Phone #: ###-####
BLD-Foundation9/27/20169/28/20169/28/2016APASS
DetailsMike Jordan
Rebar later is fine // Brian Phone #: ###-####
BLD-Foundation9/22/20169/23/20169/23/2016APASS
DetailsPhil Shearer
Brian Phone #: ###-####
OVERRIDE  8/29/2016  
Routing Walk-In (Zoning)8/29/20168/29/20168/29/2016ADONE
DetailsLeon Letson
Routing Walk-In (BLD)8/29/20168/29/20168/29/2016ADONE
DetailsBrian McGowan
1st review completed  8/29/2016 DONE
DetailsBrian McGowan
Routing - PLAN CHECK8/29/2016 8/29/2016 PASS
DetailsBrian McGowan
Case Summary (BLD)  8/29/2016 DONE
DetailsBrian McGowan
Inspection Record Card- Bld  8/29/2016 DONE
DetailsBrian McGowan
PLANS/APPL TAKEN TO FRONT DESK  8/29/2016 DONE
DetailsBrian McGowan
Permit Ready to Issue  8/29/2016 DONE
Issue PAID IN FULL permit  8/29/2016 DONE
Application received 8/29/2016