Information based on query as of Sunday, June 14, 2026.
Permit Information
Permit NumberBLD16-03291
StatusFinaled
Name EKC INC
Site Address 981 W GROVE ST
Project NameChandler's Remodel and Expan
Customer Number 
ePlanReviewYes
Description
(CHANDLER’S RESTAURANT – STATEHOUSE INN – REMODEL AND EXPANSION) (DRH16-00125) The fire sprinkler system is required for occupancy. To expand the dining area of an existing restaurant located on the 1st story of an existing building by about 164 square feet by constructing a building addition into an area that was previously part of the elevated patio dining area. Demolition work includes removing soffits/awnings, removing standing seam metal roofing on the soffits/awnings that will remain, removing a fabric awning, removing skylights, and removing storefront windows. New work is to include steel columns with Sonotube formed concrete footings for sail tie downs (shade structure). Building addition work is to include concrete footings, concrete piers, concrete stem walls, concrete slab on grade, steel columns with steel base plates to support new roofs, steel beams to support new roofs, steel cold formed roof joists, exterior storefront glazing, and finishes. Special Inspection is required for concrete, for welding, for post installed anchors / rebar in existing concrete and masonry, for spray applied fire-resistant materials, and for soils. New roof infills will be constructed to replace removed skylights. New roofs, new columns, new beams, and bearing walls are required to have a fire-resistance-rating of at least 1-hr. Exterior and interior nonbearing walls are required to be constructed of noncombustible materials but are not required to have a fire-resistance-rating. In addition, to install new kitchen equipment including a Type 2 exhaust hood above the dishwasher with duct system and exhaust fan. A new grease exhaust fan and new make-up air unit to serve the existing Type 1 hood and duct system will be installed. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 6/17/20176/20/2017 DONE
This permit finaled on the web by Cecyle Brock
Third Notice 5/15/20176/12/2017 DONE
Mailed 6-13-17
Third Notice 4/16/20175/10/2017 DONE
Mailed 5-11
Second Notice 3/20/20174/11/2017 DONE
Mailed 4-12-17
First Notice 2/20/20173/10/2017 DONE
sent in mail 3-10-17
BLD-Final2/10/20172/10/20172/10/2017PPASS
DetailsDave Hannah
Josh Phone #: ###-####
Zoning Approval2/10/20172/10/20172/10/2017 PASS
DetailsSarah Schafer
Approved. The work to be completed with the roof structural fail on the east end is to be done under and MIS permit. The BND will be released.
Permanent Occupancy  2/10/2017 DONE
DetailsChristina Prado
Permanent Occupancy  2/10/2017 DONE
BLD-Final2/6/20172/6/20172/6/2017PPART
DetailsDave Hannah
Josh//Inspection for temp. occupancy Phone #: ###-#### ok for temp occ
Temporary Occupancy2/6/20175/7/20172/6/2017 DONE
DetailsKristal Soland
Zoning Approval Temp2/6/20172/6/20172/6/2017 DONE
DetailsAndrea Tuning
A bond has been placed and recorded for the incomplete improvements.
BLD-Final2/2/20172/3/20172/3/2017PFAIL
DetailsMike Jordan
josh Phone #: ###-####. Nees zoning final.. Also noted that existing gate was to be removed from outdoor seating and handrails installed as this is part of the egress path as noted on the approved plans.
FIRE-Final Inspection2/2/20172/2/20172/2/2017PPASS
DetailsJim Page
Fire sprinkler inspection complete, fire alarm inspection complete, fire extinguishers are in place with current inpection tags. Final life fire safety inspection passed/complete
BLD-Other1/23/20171/23/20171/23/2017PPASS
DetailsDave Hannah
Josh-fire proofing Phone #: ###-####
BLD-Energy code compliance1/19/20171/19/20171/20/2017PPASS
DetailsDave Hannah
Insulation // Josh Phone #: ###-####
BLD-Energy code compliance1/17/20171/18/20171/18/2017APASS
DetailsDave Hannah
josh Phone #: ###-#### new sections of the roof
BLD-Framing/Rough-in1/17/20171/17/20171/17/2017PPASS
DetailsDave Hannah
josh Phone #: ###-#### roofs
BLD-Framing/Rough-in1/12/20171/13/20171/13/2017APART
DetailsDave Hannah
josh Phone #: ###-#### ok to insulate skylights 1 and 3
Issue PAID IN FULL permit  12/6/2016 DONE
Print Occupancy Form  12/6/2016 DONE
Telephone call  12/5/2016 DONE
called EKC to let know new fees-PW assigned new fees
OVERRIDE  11/30/2016  
Plan assigned to (CJW)9/21/20169/21/201611/30/2016 PASS
DetailsCarl Westfall
(1st done) (Oct 11 - 15 days) Chandler's Remodel
Routing - PLAN CHECK11/29/2016 11/30/2016 PEND
DetailsCarl Westfall
Pending approval by structural
Routing Off Site - STRUCTURAL11/30/2016 11/30/2016 FAIL
DetailsCarl Westfall
Jan Welch (AM)
Plan resubmittals requested  11/30/2016 DONE
(PM)
Routing - PLAN CHECK11/30/2016 11/30/2016 PASS
DetailsCarl Westfall
Approved by structural
Routing Off Site - STRUCTURAL11/30/2016 11/30/2016 PASS
DetailsCarl Westfall
Jan Welch (PM)
Plan resubmittals requested  11/30/2016 DONE
Plan resubmittals received  11/30/2016 DONE
(PM)
PLANS/APPL TAKEN TO FRONT DESK  11/30/2016 DONE
Permit Ready to Issue  11/30/2016 DONE
***all requirments met 12-1-16 /CEV

need RP, GC & rev cert of val
Plan resubmittals received  11/29/2016 DONE
Routing - PLAN CHECK11/9/2016 11/22/2016 PEND
DetailsCarl Westfall
Pending approval by the Consultant Structural Engineer
Plan resubmittals requested  11/22/2016 DONE
Routing Off Site - STRUCTURAL11/10/2016 11/18/2016 FAIL
DetailsCarl Westfall
Jan Welch
Plan resubmittals received  11/9/2016 DONE
Routing Off Site - C.D.H9/21/2016 10/6/2016 PASS
DetailsCarl Westfall
Joe Antonucci
1st review completed  10/6/2016 DONE
Plan resubmittals requested  10/6/2016 DONE
Plan resubmittals requested  10/5/2016 DONE
Routing - PLAN CHECK9/21/2016 10/5/2016 FAIL
DetailsCarl Westfall
See the plan review report
Routing - MECHANICAL9/21/2016 9/29/2016 PASS
DetailsChad Schwendiman
Routing Off Site - STRUCTURAL9/21/2016 9/28/2016 FAIL
DetailsCarl Westfall
Jan Welch
Routing PW Environmental9/21/2016 9/23/2016 PASS
DetailsRick Christenson
Routing - FIRE9/21/20169/21/20169/21/2016 PASS
DetailsKatie Marron
Comments attached to case.
Intake Approval  9/21/2016 PASS
DetailsAdele J Schaffeld-Griffin
approved by Carl M
Routing - PLUMBING9/21/2016 9/21/2016 PASS
DetailsBill VanDegrift
per plans and ISPC
Routing - Addressing9/21/2016 9/21/2016 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS9/21/2016 9/21/2016 PASS
DetailsBeverly Mountain
Routing - Erosion and Sediment9/21/2016 9/21/2016 PASS
DetailsEvan Jenkins
Dining addition to existing restaurant with new roofing elements at existing entry and addition, with update to existing roofing to match.
Routing - Design Review9/21/2016 9/21/2016 PASS
DetailsJosh Wilson
Ok per DRH16-00125
Intake Approval  9/20/2016 FAIL
1st pre-screen 9-20-16 Carl Madsen ###-####
1. Please provide a minimum of a ESC waiver letter as some exterior work is occurring.
Application received  9/7/2016 DONE
Application submitted via PDS Online on Sep 7 2016 11:37AM