BLD-Final | 11/30/2017 | 12/1/2017 | 11/30/2017 | A | PASS |
Brandon Shaw
|
|
|
Dining room/patio sliding door and Master bedroom slider, at final, permanent locks (tools required) had been installed. Rear patio/deck to be permited and installed at a later time
|
DOC - Permit Finaled | 11/30/2017 | 11/30/2017 | 11/30/2017 | P | PASS |
Brandon Shaw
|
|
|
|
PubWorks Occupancy Approval | 11/30/2017 | 11/30/2017 | 11/30/2017 | | DONE |
Jason C. Taylor
|
|
|
A letter from the applicant’s civil engineer indicating that the final grading and drainage is acceptable has been received by Public Works. Final occupancy may be approved by the building department Jason Taylor ###-####.
|
BLD-Final | 11/21/2017 | 11/21/2017 | 11/21/2017 | P | NR |
Brandon Shaw
|
|
|
James Phone #: ###-####
|
BLD-Energy code compliance | 7/27/2017 | 7/28/2017 | 7/28/2017 | P | PASS |
Brandon Shaw
|
|
|
James Phone #: ###-####
|
BLD-Framing/Rough-in | 7/25/2017 | 7/26/2017 | 7/26/2017 | A | PART |
Brandon Shaw
|
|
|
See corection notice Need revised Engineering for missing beams
|
BLD-Energy code compliance | 7/25/2017 | 7/25/2017 | 7/25/2017 | P | NR |
Brandon Shaw
|
|
|
Need framing rough-in prior to energy code.
|
BLD-Wall Bracing | 7/24/2017 | 7/24/2017 | 7/24/2017 | P | PART |
Brandon Shaw
|
|
|
Blocking for garage wall done Nail header and hold down at North( main entry steps) wall
|
BLD-Wall Bracing | 7/21/2017 | 7/21/2017 | 7/21/2017 | P | FAIL |
Brandon Shaw
|
|
|
See correction notice and red crayon
|
BLD-Conference | 1/6/2017 | 1/9/2017 | 1/9/2017 | A | PASS |
Phil Shearer
|
|
|
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro
|
BLD-Foundation | 1/9/2017 | 1/9/2017 | 1/9/2017 | P | PASS |
Phil Shearer
|
|
|
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro
|
BLD-Foundation | 12/29/2016 | 12/30/2016 | 12/30/2016 | A | FAIL |
Phil Shearer
|
|
|
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro. Only 9 degrees no heat.
|
BLD-Footing | 12/15/2016 | 12/16/2016 | 12/16/2016 | A | PART |
Phil Shearer
|
|
|
As late as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro.
|
PubWorks Subgrade Approval | 12/16/2016 | 12/16/2016 | 12/16/2016 | | DONE |
Jason C. Taylor
|
|
|
**Perimeter footings only***A letter from the applicant’s geotechnical engineer indicating that the footing subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Jason Taylor ###-####.
|
FIRE-Conference | 11/23/2016 | 11/23/2016 | 11/23/2016 | P | DONE |
Katie Marron
|
|
|
Discussion with homeowner: revised driveway meets grade requiremet for FD Access per Assistant Fire Marshall. No sprinkleres are required.
|
Issue PAID IN FULL permit | | | 11/15/2016 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 11/15/2016 | | DONE |
|
|
|
|
OVERRIDE | | | 11/9/2016 | | |
|
|
|
|
Plan assigned to (DAF) | 10/7/2016 | 10/7/2016 | 11/9/2016 | | DONE |
David Ferguson
|
|
|
due 10/18 - plan review #2 failed - eng. stamp on page A-2
|
Routing PW Grading-Hillside | 11/9/2016 | | 11/9/2016 | | PASS |
Jason C. Taylor
|
|
|
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at ###-####
Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at ###-####.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/9/2016 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 11/9/2016 | | DONE |
|
|
|
All requirements met
|
Routing - PLAN CHECK | 11/1/2016 | | 11/1/2016 | | PASS |
David Ferguson
|
|
|
|
Routing PW Grading-Hillside | 10/24/2016 | | 10/24/2016 | | FAIL |
Jason C. Taylor
|
|
|
See changemark in ePlan. JCT
|
Routing - MECHANICAL | 10/18/2016 | | 10/18/2016 | | PASS |
Troy James
|
|
|
redlined plans
|
Routing - PLAN CHECK | 10/18/2016 | | 10/18/2016 | | FAIL |
David Ferguson
|
|
|
Need engineers stamp on page A-2
|
Routing - PLANNING | 10/5/2016 | | 10/17/2016 | | PASS |
Susan Riggs
|
|
|
CFH16-00047
|
Routing PW Grading-Hillside | 10/5/2016 | | 10/14/2016 | | FAIL |
Jason C. Taylor
|
|
|
Upload new grading plans.
|
1st review completed | | | 10/11/2016 | | FAIL |
David Ferguson
|
|
|
|
Routing - PLAN CHECK | 10/5/2016 | | 10/11/2016 | | FAIL |
David Ferguson
|
|
|
|
Plan assigned to (LEG) Tisha | 10/5/2016 | | 10/7/2016 | | DEFR |
Tisha Gallop
|
|
|
|
Routing - FIRE | 10/5/2016 | 10/5/2016 | 10/5/2016 | | PASS |
Katie Marron
|
|
|
THIS STRUCTURE IS REQUIRED TO BE FIRE SPRINKLERED IN ACCORDANCE WITH NFPA13D, DUE TO LIMITED FD ACCESS AND DRIVEWAY SLOPE. AS STATED UNDER CFH16-00047). A SEPARATE FIRE PERMIT WILL BE REQUIRED.
|
Routing - MECHANICAL | 10/5/2016 | | 10/5/2016 | | FAIL |
Troy James
|
|
|
Left message with James with stock const.
|
Routing - Addressing | 10/5/2016 | | 10/5/2016 | | PASS |
Laura Hunter
|
|
|
|
Routing - PUBLIC WORKS | 10/5/2016 | | 10/5/2016 | | PASS |
Rachael Beierle
|
|
|
|
Routing - Erosion and Sediment | 10/5/2016 | | 10/5/2016 | | PASS |
Andy J. Long
|
|
|
ESC plan submitted and approved. Valid RP and PD desingated.
|
Plans ACCEPTED BY PLAN TECH | | | 10/5/2016 | | DONE |
|
|
|
|
Intake Approval | | | 10/5/2016 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 10/5/2016 | | DONE |
|
|
|
|
Intake Approval | | | 9/26/2016 | | FAIL |
Christina Prado
|
|
|
Must wait until appeal period is up - 9-29-16 at 5PM
|
Application received | | | 9/8/2016 | | DONE |
|
|
|
Application submitted via PDS Online on Sep 8 2016 4:45PM
|