Third Notice | | 10/17/2017 | 10/16/2017 | | DONE |
|
|
|
This permit finaled on the web by Melanie Kreizenbeck
|
Second Notice | | 9/29/2017 | 10/12/2017 | | DONE |
|
|
|
Mailed 10-13-17
|
First Notice | 9/7/2017 | 9/7/2017 | 9/19/2017 | | DONE |
Candy A. Nichols
|
|
|
sent in mail 9-20-17 pdf
|
BLD-Final | 9/7/2017 | 9/7/2017 | 9/7/2017 | P | PASS |
Mike Jordan
|
|
|
Foundation permit only // Herb Phone #: ###-####
|
DOC - Permit Finaled | 9/7/2017 | 9/7/2017 | 9/7/2017 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Aging Inspection | 8/25/2017 | 8/25/2017 | 8/25/2017 | | PASS |
Mike Jordan
|
|
|
|
BLD-Framing/Rough-in | 4/12/2017 | 4/13/2017 | 4/13/2017 | A | PASS |
Mike Jordan
|
|
|
Roof nailing on porte cachere ok.
|
BLD-Framing/Rough-in | 4/10/2017 | 4/12/2017 | 4/12/2017 | P | CANC |
Mike Jordan
|
|
|
|
BLD-Framing/Rough-in | 4/10/2017 | 4/12/2017 | 4/12/2017 | A | CANC |
Mike Jordan
|
|
|
|
BLD-Framing/Rough-in | 4/10/2017 | 4/10/2017 | 4/10/2017 | A | CANC |
Mike Jordan
|
|
|
|
BLD-Framing/Rough-in | 4/10/2017 | 4/10/2017 | 4/10/2017 | P | PART |
Mike Jordan
|
|
|
Ok to insulate exterior walls on rooms 134 to 142 only.
|
BLD-Framing/Rough-in | 3/22/2017 | 3/29/2017 | 3/29/2017 | P | PASS |
Mike Jordan
|
|
|
Roof nailing Central portion between courtyards.
|
BLD-Framing/Rough-in | 3/29/2017 | 3/29/2017 | 3/29/2017 | A | PART |
Mike Jordan
|
|
|
Roff nailing east of portecahier
|
BLD-Framing/Rough-in | 3/15/2017 | 3/22/2017 | 3/22/2017 | P | PASS |
Mike Jordan
|
|
|
Roof nailing, central portion ok.
|
BLD-Framing/Rough-in | 3/15/2017 | 3/22/2017 | 3/22/2017 | A | PEND |
Mike Jordan
|
|
|
Walk through south wing with contractor, noted some areas to add squash blocking and adiitional studs under 2ply girders. Also inspected the work in profress on the 2hr. fire wall.
|
BLD-Footing | 3/20/2017 | 3/21/2017 | 3/21/2017 | A | PEND |
Mike Jordan
|
|
|
Herb Phone #: ###-####. Interior thickend footings under slab. Pending special inspection.
|
BLD-Framing/Rough-in | 3/8/2017 | 3/15/2017 | 3/15/2017 | P | PART |
Mike Jordan
|
|
|
South wing, general walk through of work in progress.
|
BLD-Wall Bracing | 3/15/2017 | 3/15/2017 | 3/15/2017 | P | PART |
Mike Jordan
|
|
|
Exterior shear walls. south half. Noted some holdowns not yet fastened on east side. Also one area needs to br nailed that is not attached east side as well.
|
BLD-Framing/Rough-in | 3/8/2017 | 3/8/2017 | 3/8/2017 | P | CANC |
Mike Jordan
|
|
|
|
BLD-Framing/Rough-in | 3/2/2017 | 3/8/2017 | 3/8/2017 | P | PART |
Mike Jordan
|
|
|
Roof nailing, north wing, south side. Needs to nail off drag trusses.
|
BLD-Footing | 3/1/2017 | 3/2/2017 | 3/2/2017 | P | PART |
Mike Jordan
|
|
|
Herb Phone #: ###-####. Interior thickend footings under slab. Work in progress. Will have special inspection.
|
Telephone call | | | 1/9/2017 | | DONE |
|
|
|
called GC to make sure they call any inspections for the foundation in on BLD16-03666 not BLD16-02899-
|
BLD-Footing | 12/1/2016 | 12/2/2016 | 12/2/2016 | P | PART |
Mike Jordan
|
|
|
herb Phone #: ###-####. Work in progress on interior thickend footings.
|
BLD-Footing | 11/18/2016 | 11/21/2016 | 11/21/2016 | A | DEFR |
Mike Jordan
|
|
|
Hurb Phone #: ###-####. Inter thickend footings under slab on grade. Already placed when on site. Inspected by special inspector on site.
|
BLD-Energy code compliance | 11/7/2016 | 11/8/2016 | 11/8/2016 | A | PASS |
Mike Jordan
|
|
|
Herb Phone #: ###-####. rigid insulation on stemwall under slab on grade ok. Remainder of exterior footings and north courtyard footings.
|
BLD-Foundation | 11/2/2016 | 11/3/2016 | 11/3/2016 | A | PART |
Mike Jordan
|
|
|
Kip Phone #: ###-####. Stemwalls for north courtyard. Will have special inspections. Also noted all missing corner bar noted on previous inspection was installed per the special inspection report.
|
BLD-Foundation | 10/31/2016 | 11/1/2016 | 11/1/2016 | A | PART |
Mike Jordan
|
|
|
Phone #: ###-####. North, east and west exterior stemwalls. Needs to add 90's at wall corners. Special inspector to verify.
|
BLD-Foundation | 10/25/2016 | 10/26/2016 | 10/26/2016 | P | PASS |
Mike Jordan
|
|
|
Herb Phone #: ###-####. North courtyard footings, nort exterior footing and remainder of east and west exterior footings.
|
BLD-Footing | 10/24/2016 | 10/25/2016 | 10/25/2016 | A | CANC |
Mike Jordan
|
|
|
Herb-pour time 8:30 AM Phone #: ###-####
|
BLD-Energy code compliance | 10/25/2016 | 10/25/2016 | 10/25/2016 | A | PASS |
Mike Jordan
|
|
|
Herb-pour time 8:30 AM Phone #: ###-####. Rigid insulation, at stemwall,interior side, under slab on grade at Footings for south courtyard, east exterior footing, south exterior footing and approx. 25 l.f. of south west exterior footing ok.
|
BLD-Foundation | 10/25/2016 | 10/25/2016 | 10/25/2016 | A | PASS |
Mike Jordan
|
|
|
Herb-pour time 8:30 AM Phone #: ###-####. Footings for south courtyard, east exterior footing, south exterior footing and approx. 25 l.f. of south west exterior footing ok. Special inspector on site.
|
BLD-Foundation | 10/11/2016 | 10/12/2016 | 10/12/2016 | P | PASS |
Mike Jordan
|
|
|
Herb Phone #: ###-####. Footings for south courtyard, east exterior footing, south exterior footing and approx. 25 l.f. of south west exterior footing ok.
|
OVERRIDE | | | 10/5/2016 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 10/5/2016 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 10/5/2016 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 10/5/2016 | | DONE |
|
|
|
All requirements met
|
Plan assigned to (CDM) | 10/4/2016 | 10/4/2016 | 10/4/2016 | | PASS |
Carl D Madsen
|
|
|
|
Case Summary (BLD) | | | 10/4/2016 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/4/2016 | | DONE |
|
|
|
|
1st review completed | | | 10/4/2016 | | DONE |
|
|
|
|
Intake Approval | | | 10/4/2016 | | |
|
|
|
|
Meeting | | | 10/4/2016 | | |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 10/4/2016 | | |
|
|
|
|
Intake Approval | | | 10/4/2016 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 10/4/2016 | | |
|
|
|
|
Routing - PLAN CHECK | 10/4/2016 | | 10/4/2016 | | PASS |
Carl D Madsen
|
|
|
Ok to issue with underground plumbing per Bill V . The civil plans now indicate schedule 40 drain pipe under the building for the courtyard drains. CDM 10-4-16
|
Application received | | 10/4/2016 | | | |
|
|
|
|
Application received | | 10/4/2016 | | | |
|
|
|
|