Permit Information
Permit NumberBLD16-03672
StatusFinaled
Name VERTICAL CORP
Site Address 380 S 8TH ST
Project NameUpCycle
Customer Number 
ePlanReviewYes
Description
(UPCYCLE – FITNESS FACILITY – 1ST STORY – NEAR THE SW CORNER) The fire sprinkler system is used for fire area and for a multi-theater complex. Interior demolition work includes removing nonbearing walls and removing a concrete slab to facilitate new under-slab plumbing. To remodel an existing 4,323 square foot tenant space to be used as an exercise and physical training facility. Work is to include interior nonbearing walls, 2 single-user uni-sex shower rooms accessible to the disabled, 1 single-user uni-sex shower room NOT accessible to the disabled, a multi-user Women’s shower room accessible to the disabled, a single-user uni-sex dressing room accessible to the disabled, 2 single-user uni-sex dressing rooms NOT accessible to the disabled, a terraced elevated noncombustible floor within a cycle studio, interior doors, lockers, millwork, gypsum board ceilings and soffits, suspended acoustical ceilings, and finishes. Some of the existing suspended acoustical ceiling will remain. Floor and wall finishes within the existing restrooms will be replaced. The restrooms are required to be accessible to the disabled as defined by current standards. A clothes dryer duct will be installed that will extend to the outside. New shower exhaust ducts will be connected to the main building exhaust duct system. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system, if any, is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 4/21/20174/21/2017 DONE
This permit finaled on the web by Todd Weltner
First Notice 4/9/20174/11/2017 DONE
Mailed 4-12-17
Permanent Occupancy  3/30/2017 DONE
Telephone call  3/22/2017 DONE
called to let know Temp C of O will expire next week-left message on the main menue at ###-####
BLD-Final2/15/20172/16/20172/16/2017PPASS
DetailsDave Hannah
Josh Phone #: ###-####
(F) Reprint permit  1/30/2017 DONE
Temporary Occupancy1/26/20174/26/20171/26/2017 DONE
DetailsCandy A. Nichols
BLD-Final12/27/201612/28/201612/28/2016APART
DetailsDave Hannah
Ron Phone #: ###-#### ok for temp occ needs ade counter top and finish set up
FIRE-Final Inspection12/27/201612/27/201612/27/2016APASS
DetailsJim Page
Final fire sprinkler inspection complete, final fire alarm inspection complete, fire extinguisher will be mounted in discussed location. Final life fire safety inspection passed/complete.
BLD-Other12/16/201612/16/201612/16/2016PPASS
DetailsJim Storey
ceiling grid; ron Phone #: ###-####
BLD-Framing/Rough-in11/21/201611/22/201611/22/2016APASS
DetailsDave Hannah
ron Phone #: ###-####
Issue PAID IN FULL permit  11/7/2016 DONE
Print Occupancy Form  11/7/2016 DONE
OVERRIDE  11/1/2016  
Plan assigned to (CJW)10/5/201610/5/201611/1/2016 PASS
DetailsCarl Westfall
(1st done) (Oct 25 - 15 days) fitness
Routing - PLUMBING10/31/2016 11/1/2016 PASS
DetailsBill VanDegrift
per plans and ISPC
PLANS/APPL TAKEN TO FRONT DESK  11/1/2016 DONE
Permit Ready to Issue  11/1/2016 DONE
***all requirments met 11-7-16 /CEV

need RP, GC & rev cert of val
Plan resubmittals received  10/31/2016 DONE
Workflow actually came in at about 4:30 on Friday October 28.
Routing - PLAN CHECK10/31/2016 10/31/2016 PASS
DetailsCarl Westfall
Routing - MECHANICAL10/31/2016 10/31/2016 PASS
DetailsTroy James
1st review completed  10/28/2016 DONE
Plan resubmittals requested  10/28/2016 DONE
Routing - PLAN CHECK10/5/2016 10/28/2016 PASS
DetailsCarl Westfall
Drawings approved with redlines
Routing - MECHANICAL10/5/2016 10/10/2016 FAIL
DetailsTroy James
Routing - PLUMBING10/5/2016 10/10/2016 FAIL
DetailsBill VanDegrift
10 size water system in accordance with the uniform plumbing code.
2) vent all traps
Routing - FIRE10/5/201610/5/201610/5/2016 PASS
DetailsKatie Marron
Comments attached to case.
Plan Reviewer's activity  10/5/2016 DONE
DetailsJavier Guzman
emailed architect letting him know this project is not a minor but instead a major T.I. due to the change of use
Intake Approval  10/5/2016 PASS
DetailsJavier Guzman
Routing - Addressing10/5/2016 10/5/2016 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS10/5/2016 10/5/2016 PASS
DetailsRachael Beierle
Routing - Erosion and Sediment10/5/2016 10/5/2016 PASS
DetailsAndy J. Long
ESC plan waiver approved.
Application received  10/4/2016 DONE
Application submitted via PDS Online on Oct 4 2016 3:03PM