BLD-Final | 12/21/2016 | 12/22/2016 | 12/22/2016 | A | PASS |
Mike Jordan
|
|
|
Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane
|
DOC - Permit Finaled | 12/22/2016 | 12/22/2016 | 12/22/2016 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Final | 12/17/2016 | 12/19/2016 | 12/19/2016 | A | NR |
Mike Jordan
|
|
|
Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane. Exterior not complete.
|
BLD-Energy code compliance | 11/9/2016 | 11/10/2016 | 11/10/2016 | A | PASS |
Mike Jordan
|
|
|
Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane
|
BLD-Framing/Rough-in | 11/9/2016 | 11/10/2016 | 11/10/2016 | A | PASS |
Mike Jordan
|
|
|
Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane
|
BLD-Energy code compliance | 11/7/2016 | 11/9/2016 | 11/9/2016 | P | FAIL |
Mike Jordan
|
|
|
Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane. Not all framing corrections have been completed..
|
BLD-Conference | 11/7/2016 | 11/8/2016 | 11/8/2016 | P | CANC |
Mike Jordan
|
|
|
Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane
|
BLD-Framing/Rough-in | 11/7/2016 | 11/8/2016 | 11/8/2016 | P | FAIL |
Mike Jordan
|
|
|
Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane. Fire block barrel vault in hallway at ceiling.. Provide min. 2 10d nails on lateral bracing to framing member. Provide 4SDS screws in ledger at kitschen. Only three provided. Provide anchor bolts in sole plate for bearing wall in garage. nail off bonus room shear walls and install missing blocking. Correction notice posted. Ok to insulate.
|
BLD-Wall Bracing | 10/24/2016 | 10/26/2016 | 10/26/2016 | A | PASS |
Mike Jordan
|
|
|
Zane Phone #: ###-####
|
BLD-Foundation | 10/13/2016 | 10/14/2016 | 10/14/2016 | P | PASS |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 10/13/2016 | 10/14/2016 | 10/14/2016 | A | PASS |
Jim Sly
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 10/12/2016 | 10/13/2016 | 10/13/2016 | P | CANC |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
Issue PAID IN FULL permit | | | 10/11/2016 | | DONE |
|
|
|
|
OVERRIDE | | | 10/10/2016 | | |
|
|
|
|
Inspection Record Card- Bld | | | 10/10/2016 | | DONE |
|
|
|
|
Telephone call | | | 10/10/2016 | | DONE |
|
|
|
called Tom- left message that permit is ready and fee due
|
Plan assigned to (LEG) Tisha | 10/6/2016 | | 10/10/2016 | | DONE |
Tisha Gallop
|
|
|
10/19
|
Routing - MECHANICAL | 10/7/2016 | | 10/10/2016 | | PASS |
Troy James
|
|
|
|
Routing - PLAN CHECK | 10/10/2016 | | 10/10/2016 | | PASS |
Tisha Gallop
|
|
|
|
Case Summary (BLD) | | | 10/10/2016 | | DONE |
|
|
|
|
1st review completed | | | 10/10/2016 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/10/2016 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 10/10/2016 | | DONE |
|
|
|
MET
|
Routing - PLANNING | 10/6/2016 | | 10/7/2016 | | PASS |
Jeff Lowe
|
|
|
|
Routing - Addressing | 10/6/2016 | | 10/6/2016 | | PASS |
Emily Dixon
|
|
|
|
Routing - PUBLIC WORKS | 10/6/2016 | | 10/6/2016 | | PASS |
Morgan Webb
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 10/6/2016 | | DONE |
|
|
|
|
Intake Approval | | | 10/6/2016 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 10/6/2016 | | DONE |
|
|
|
|
Application received | | 10/6/2016 | | | |
|
|
|
|