BLD-Aging Inspection | 8/24/2017 | 8/24/2017 | 8/31/2017 | | DONE |
Tony Young
|
|
|
|
BLD-Aging Inspection | 8/23/2017 | 8/23/2017 | 8/29/2017 | | DONE |
Tony Young
|
|
|
|
DOC - Permit Finaled | 8/29/2017 | 8/29/2017 | 8/29/2017 | P | PASS |
Tony Young
|
|
|
|
BLD-Final | 4/10/2017 | 4/11/2017 | 4/11/2017 | A | PASS |
Tony Young
|
|
|
Call for access // Chi Phone #: ###-####
|
BLD-Blower Door Test Results | 4/10/2017 | 4/11/2017 | 4/11/2017 | A | PASS |
Tony Young
|
|
|
Call for access // Chi Phone #: ###-####,, 3.5
|
BLD-Final | 4/5/2017 | 4/6/2017 | 4/6/2017 | P | FAIL |
Jim Sly
|
|
|
Call for access // Shane Phon C/N posted.
|
BLD-Energy code compliance | 1/27/2017 | 1/30/2017 | 1/30/2017 | P | PASS |
Jim Sly
|
|
|
steve Phone #: ###-####
|
BLD-Framing/Rough-in | 1/27/2017 | 1/27/2017 | 1/27/2017 | P | FAIL |
Mike Jordan
|
|
|
thi Phone #: ###-####. Fire block tall by stairs at 10ft.. Fireblock mech. shaft upstairs at ceiling level. Provide adequate bearing on D02 truss upstairs. Provide header on interior wall upstairs at truss bearing. Correction notice posted. Ok to insualte.
|
BLD-Wall Bracing | 1/24/2017 | 1/24/2017 | 1/24/2017 | P | PART |
Tony Young
|
|
|
Chi Phone #: ###-####,, exterior ok
|
Plan Modification Accepted | | | 1/19/2017 | | DONE |
|
|
|
New manual j report
|
Routing - MECHANICAL | 1/19/2017 | | 1/19/2017 | | PASS |
Troy James
|
|
|
resubmitted manual j report
|
BLD-Foundation | 11/30/2016 | 12/1/2016 | 12/1/2016 | A | PART |
Tony Young
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron,, work in progress
|
BLD-Footing | 11/29/2016 | 11/30/2016 | 11/30/2016 | P | PASS |
Tony Young
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 11/28/2016 | 11/29/2016 | 11/30/2016 | P | NR |
Tony Young
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 11/27/2016 | 11/28/2016 | 11/28/2016 | P | PASS |
Jim Sly
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
OVERRIDE | | | 11/22/2016 | | |
|
|
|
|
Plan assigned to (BJM) | 10/28/2016 | 10/28/2016 | 11/22/2016 | | DONE |
Brian McGowan
|
|
|
Due 11-4 - Failed - Failed 11-22 - Need front porch engineering
|
Routing - PLAN CHECK | 11/15/2016 | | 11/22/2016 | | FAIL |
Brian McGowan
|
|
|
No engineering provided for Covered Front Porch as perviously requested.
|
Inspection Record Card- Bld | | | 11/22/2016 | | DONE |
|
|
|
|
Telephone call | | | 11/22/2016 | | DONE |
|
|
|
called Kent- told him permit is ready and fees due
|
Issue PAID IN FULL permit | | | 11/22/2016 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 11/22/2016 | | DONE |
Brian McGowan
|
|
|
|
Routing - PLAN CHECK | 11/22/2016 | | 11/22/2016 | | PASS |
Brian McGowan
|
|
|
Front porch cover not to exceed 54" or engineering is required.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/22/2016 | | DONE |
Brian McGowan
|
|
|
|
Permit Ready to Issue | | | 11/22/2016 | | DONE |
|
|
|
MET
|
Routing - PLANNING | 11/18/2016 | | 11/21/2016 | | PASS |
David Moser
|
|
|
|
Plan resubmittals received | | | 11/16/2016 | | DONE |
|
|
|
resubmittals recieved 2 sets of sheets 1-11-took to Brian McGowan
|
Plan resubmittals received | | | 11/15/2016 | | DONE |
|
|
|
received (2) sets of revised structural drawings
|
1st review completed | | | 11/10/2016 | | FAIL |
Brian McGowan
|
|
|
Setback issues, wall bracing calcs and panels, cross section, stem wall detail.
|
Routing - PLAN CHECK | 10/31/2016 | | 11/10/2016 | | FAIL |
Brian McGowan
|
|
|
Setback issues, wall bracing calcs and panels, cross section, stem wall detail.
|
Routing - MECHANICAL | 11/7/2016 | | 11/7/2016 | | PASS |
Troy James
|
|
|
|
Routing - MECHANICAL | 10/27/2016 | | 10/31/2016 | | FAIL |
Troy James
|
|
|
emailed corrections to Legends mech
|
Plan assigned to (LEG) Tisha | 10/24/2016 | | 10/28/2016 | | DEFR |
Tisha Gallop
|
|
|
|
Routing - PLAN CHECK | 10/24/2016 | | 10/27/2016 | | PEND |
Tisha Gallop
|
|
|
routed to plan check by mistake. I routed it to planning
|
Routing - PLANNING | 10/27/2016 | | 10/27/2016 | | FAIL |
David Moser
|
|
|
The eave on the front of the house by the entry shall not project more than 2 feet into setback.
|
Routing - Addressing | 10/24/2016 | | 10/24/2016 | | PASS |
Laura Hunter
|
|
|
|
Routing - PUBLIC WORKS | | | 10/24/2016 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 10/24/2016 | | DONE |
|
|
|
|
Intake Approval | | | 10/24/2016 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 10/24/2016 | | DONE |
|
|
|
|
Application received | | 10/21/2016 | | | |
|
|
|
|