Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD16-03996
StatusFinaled
Name BRIGHTON HOMES IDAHO INC
Site Address 6950 E GREYBULL DR
Project NameRH-07-1610 Augusta
Customer Number 
ePlanReviewYes
Description
WUI Zone B Interior Lot - Class A Roof Required - Permit for the construction of a new 3,100 sq. ft., two story (first floor 1,480 sq. ft., second floor 1,620 sq. ft.) single family dwelling with 4 bedrooms, 2 and a half bathrooms, approximately 218 sq. ft. of covered patio/porch and a 955 sq. ft. attached garage per the approved plans, and any notations. SP-02 zoning and setbacks per planning. **DAF**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/3/20177/3/20177/3/2017PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Braxton Hansen
DOC - Permit Finaled7/3/20177/3/20177/3/2017PPASS
DetailsBrandon Shaw
BLD-Final6/29/20176/30/20176/30/2017AFAIL
DetailsBrandon Shaw
Smoke/Carbon combo needs to be installed adjacent to bedroom down stairs
BLD-Final6/29/20176/29/20176/29/2017AFAIL
DetailsBrandon Shaw
1) No plans on site
2) Seal around water spicket, East wall- insect proofing
3) Smoke/Carbon detectors missing outside/adjacent to bedrooms- Master and main floor next to kitchen
BLD-Energy code compliance3/24/20173/24/20173/24/2017PPASS
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Braxton Hansen
BLD-Framing/Rough-in3/22/20173/22/20173/23/2017PPASS
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Braxton Hansen
BLD-Framing/Rough-in3/20/20173/21/20173/21/2017PFAIL
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Braxton Hansen c/n on site
BLD-Wall Bracing2/24/20172/27/20172/27/2017APASS
DetailsJim Storey
Please inspect as early as possible Phone #: ###-#### Inspection requested via web by Braxton Hansen
BLD-Wall Bracing2/23/20172/24/20172/24/2017PFAIL
DetailsJim Storey
Shear Phone #: ###-#### Inspection requested via web by Braxton Hansen overdriven nails/ not built per the plan
BLD-Foundation12/22/201612/23/201612/23/2016APASS
DetailsJim Sly
Doug Phone #: ###-####
Talked to Contr......OK to pour if he follows ACI 306 cold weather concrete standard.
BLD-Foundation12/22/201612/22/201612/22/2016PNR
DetailsTony Young
Doug Phone #: ###-####,, called and left a voice mail,, no one on site,, appears that the rebar is in place,, covered with one layer of blankets
BLD-Foundation12/16/201612/16/201612/16/2016PNR
DetailsPhil Shearer
Doug Phone #: ###-####
BLD-Footing12/7/201612/8/201612/8/2016APASS
DetailsPhil Shearer
keith Phone #: ###-####
BLD-Footing12/7/201612/7/201612/7/2016PNR
DetailsPhil Shearer
Doug Phone #: ###-####
BLD-Footing12/6/201612/6/201612/6/2016PNR
DetailsDave Hannah
Keith Phone #: ###-####
Inspection Record Card- Bld  11/23/2016 DONE
Issue PAID IN FULL permit  11/21/2016 DONE
Inspection Record Card- Bld  11/21/2016 DONE
OVERRIDE  11/16/2016  
Plan assigned to (DAF)11/5/201611/5/201611/16/2016 DONE
DetailsDavid Ferguson
due 11/17
1st review completed  11/16/2016 DONE
DetailsDavid Ferguson
PLANS/APPL TAKEN TO FRONT DESK  11/16/2016 DONE
Permit Ready to Issue  11/16/2016 DONE
DetailsChristina Prado
All requirements met
Routing - PLAN CHECK11/4/2016 11/16/2016 PASS
DetailsDavid Ferguson
Routing - MECHANICAL11/4/2016 11/7/2016 PASS
DetailsTroy James
Routing - Addressing11/4/2016 11/7/2016 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS11/4/2016 11/7/2016 PASS
DetailsMorgan Webb
Plan assigned to (LEG) Tisha11/4/2016 11/5/2016 DEFR
DetailsTisha Gallop
Routing - PLANNING11/4/2016 11/4/2016 PASS
DetailsNicolette Womack
Intake Approval  11/4/2016 PASS
Application received  10/31/2016 DONE
Application submitted via PDS Online on Oct 31 2016 3:46PM