PubWorks Occupancy Approval | 4/16/2018 | 4/16/2018 | 4/16/2018 | | DONE |
Tiffany Lowery
|
|
|
|
Permanent Occupancy | | | 4/16/2018 | | DONE |
|
|
|
|
BLD-Final | 4/11/2018 | 4/11/2018 | 4/11/2018 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by David Scaggs
|
Temporary Occupancy | 4/6/2018 | 7/5/2018 | 4/6/2018 | | DONE |
Candy A. Nichols
|
|
|
Jason B ok'd 45 day extension from 3/21/18
|
Zoning Approval | 4/2/2018 | 4/2/2018 | 4/2/2018 | | PASS |
Katelyn Menuge
|
|
|
Final
|
Telephone call | | | 3/21/2018 | | DONE |
|
|
|
called Dave to let know temp c of o has expired-left message that he needs the finals scheduled or request an extension with Jason B
|
BLD-Aging Inspection | 2/20/2018 | 2/20/2018 | 2/20/2018 | | PEND |
Mike Jordan
|
|
|
|
BLD-Final | 12/20/2017 | 12/21/2017 | 12/21/2017 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by David Scaggs. Ok for temp occ. Will be ok for perm occ. once zoning and public works signs perm.
|
FIRE-Final Inspection | 12/20/2017 | 12/21/2017 | 12/21/2017 | P | PASS |
Troy Cobbley
|
|
|
Life safety passed
Phone #: ###-#### Inspection requested via web by David Scaggs
|
Temporary Occupancy | 12/21/2017 | 3/21/2018 | 12/21/2017 | | DONE |
Christina Prado
|
|
|
|
Zoning Approval Temp | 12/14/2017 | 12/14/2017 | 12/14/2017 | | DONE |
Katelyn Menuge
|
|
|
Temp
|
PubWorks Temp Occupancy Appr | 12/14/2017 | 12/14/2017 | 12/14/2017 | | DONE |
Tiffany Lowery
|
|
|
|
Print Occupancy Form | | | 12/12/2017 | | DONE |
|
|
|
|
BLD-Energy code compliance | 10/13/2017 | 10/16/2017 | 10/16/2017 | A | PASS |
Mike Jordan
|
|
|
Dave Phone #: ###-####
|
BLD-Framing/Rough-in | 10/12/2017 | 10/12/2017 | 10/12/2017 | P | PASS |
Mike Jordan
|
|
|
Dave Phone #: ###-####
|
BLD-Wall Bracing | 7/5/2017 | 7/5/2017 | 7/5/2017 | P | PASS |
Mike Jordan
|
|
|
Shear // Marty Phone #: ###-####
|
BLD-Wall Bracing | 6/27/2017 | 6/27/2017 | 6/27/2017 | P | FAIL |
Mike Jordan
|
|
|
Marty Phone #: ###-####. Provide RFI from engineer showing that the STDH 14 holdowns are adequate in leiu of the holddowns shown on approved plans. Shhet S2.2 notes that staples shall not be substituted for nails ot shear wall locations. Missing one holddown. Correction notice put with approved plans.
|
BLD-Footing | 6/9/2017 | 6/9/2017 | 6/9/2017 | P | PASS |
Brandon Shaw
|
|
|
Marty Phone #: ###-####
|
BLD-Footing | 6/8/2017 | 6/8/2017 | 6/8/2017 | P | FAIL |
Dave Hannah
|
|
|
Marty Phone #: ###-#### as per plans ftgs should be 24x10 they are not
|
BLD-Energy code compliance | 6/6/2017 | 6/6/2017 | 6/6/2017 | P | PASS |
Mike Jordan
|
|
|
Marty Phone #: ###-####. Rigid insulation on stemwalls interior side under slab on grade.
|
BLD-Foundation | 5/25/2017 | 5/25/2017 | 5/25/2017 | P | PASS |
Mike Jordan
|
|
|
Marty Short Phone #: ###-####
|
BLD-Footing | 5/19/2017 | 5/22/2017 | 5/22/2017 | A | PASS |
Mike Jordan
|
|
|
Marty Phone #: ###-####
|
Issue PAID IN FULL permit | | | 5/9/2017 | | DONE |
Christina Prado
|
|
|
|
Inspection Record Card- Bld | | | 5/9/2017 | | DONE |
Christina Prado
|
|
|
|
Print Occupancy Form | | | 5/9/2017 | | DONE |
Christina Prado
|
|
|
|
Expiration Notice | 5/3/2017 | 5/24/2017 | 5/3/2017 | | DONE |
Brittany Hill
|
|
|
|
Plan assigned to (CDM) | 12/7/2016 | 12/7/2016 | 4/25/2017 | | PASS |
Carl D Madsen
|
|
|
1st comp. Marina Apartments
|
Routing - PLANNING Land Div | 12/7/2016 | | 4/25/2017 | | PASS |
Todd Tucker
|
|
|
|
Routing - Erosion and Sediment | 12/7/2016 | | 4/25/2017 | | PASS |
Andy J. Long
|
|
|
|
Routing - PLAN CHECK | 4/25/2017 | | 4/25/2017 | | PASS |
Carl D Madsen
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 4/25/2017 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 4/25/2017 | | DONE |
Christina Prado
|
|
|
Need GC form & RP for issuance
|
Routing - MECHANICAL | 3/2/2017 | | 4/25/2017 | | PASS |
Troy James
|
|
|
|
Routing - PLUMBING | 3/2/2017 | | 4/25/2017 | | PASS |
Bill VanDegrift
|
|
|
|
Routing - PUBLIC WORKS | 3/2/2017 | | 4/25/2017 | | PASS |
Morgan Webb
|
|
|
|
Routing - Erosion and Sediment | 3/2/2017 | | 4/25/2017 | | PASS |
Andy J. Long
|
|
|
|
Routing - Design Review | 4/12/2017 | | 4/12/2017 | | PASS |
Sarah Schafer
|
|
|
Approved per DRH17-00088.
|
Routing Off Site - STRUCTURAL | 3/2/2017 | | 3/10/2017 | | PASS |
Carl D Madsen
|
|
|
|
Routing - PLAN CHECK | 3/2/2017 | | 3/10/2017 | | FAIL |
Carl D Madsen
|
|
|
|
Routing - Design Review | 3/2/2017 | | 3/7/2017 | | FAIL |
Sarah Schafer
|
|
|
The following changes are required:
Modification required for changes to building materials.
Bike racks need to be shown on improved surface.
Additional trees in planters and along Preece
Left message for applicant today.
|
Routing - FIRE | 3/2/2017 | 3/2/2017 | 3/3/2017 | | PASS |
Scott Arellano
|
|
|
Sufficient fire flow provided.
|
Routing - PUBLIC WORKS | 12/7/2016 | | 3/2/2017 | | PASS |
Rachael Beierle
|
|
|
WEST BOISE SEWER DISTRICT
|
Route to Impact Fee Review | 1/5/2017 | 1/8/2017 | 1/9/2017 | | PASS |
Cindy M. Gould
|
|
|
|
Routing - PLAN CHECK | 12/7/2016 | | 1/5/2017 | | FAIL |
Carl D Madsen
|
|
|
|
Routing Off Site - STRUCTURAL | 12/7/2016 | | 1/5/2017 | | FAIL |
Carl D Madsen
|
|
|
|
1st review completed | | | 1/5/2017 | | FAIL |
|
|
|
|
Routing - MECHANICAL | 12/7/2016 | | 12/12/2016 | | FAIL |
Troy James
|
|
|
|
Routing - FIRE | 12/7/2016 | 12/7/2016 | 12/9/2016 | | PASS |
Katie Marron
|
|
|
No fire flow provided, will be requested under permit BLD16-04308. Comments attached to case.
|
Routing - Addressing | 12/7/2016 | | 12/8/2016 | | PASS |
Laura Hunter
|
|
|
|
Routing - PLUMBING | 12/7/2016 | | 12/8/2016 | | FAIL |
Bill VanDegrift
|
|
|
|
Routing - Design Review | 12/7/2016 | | 12/8/2016 | | FAIL |
Josh Wilson
|
|
|
Changemarks in Eplan.
|
Routing - PLANNING | 12/7/2016 | | 12/7/2016 | | PASS |
Cody Riddle
|
|
|
|
Intake Approval | | | 12/7/2016 | | PASS |
|
|
|
|
Application received | | | 11/29/2016 | | DONE |
|
|
|
Application submitted via PDS Online on Nov 29 2016 10:46AM
|
First Notice | | 4/26/2018 | | | |
|
|
|
|