BLD-Final | 3/24/2017 | 3/27/2017 | 3/27/2017 | A | PASS |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez
|
DOC - Permit Finaled | 3/27/2017 | 3/27/2017 | 3/27/2017 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Final | 3/23/2017 | 3/23/2017 | 3/23/2017 | A | NR |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Plumbing final has failed.
|
BLD-Final | 3/22/2017 | 3/22/2017 | 3/22/2017 | A | NR |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Needs plumbing final.
|
BLD-Conference | 3/22/2017 | 3/22/2017 | 3/22/2017 | A | CANC |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez Inspection cancelled via mobile web on Wednesday, March 22, 2017.
|
BLD-Energy code compliance | 2/9/2017 | 2/10/2017 | 2/10/2017 | P | PASS |
Jim Sly
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez
|
BLD-Framing/Rough-in | 2/8/2017 | 2/9/2017 | 2/9/2017 | P | FAIL |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Complete the fireblocking behind the tub, remove hangars in garage and reinstall. Truss heels not seated. ok to insulate.
|
BLD-Wall Bracing | 1/30/2017 | 1/31/2017 | 1/31/2017 | A | PASS |
Mike Jordan
|
|
|
zane Phone #: ###-####
|
BLD-Foundation | 1/12/2017 | 1/12/2017 | 1/12/2017 | P | PART |
Mike Jordan
|
|
|
|
BLD-Footing | 1/11/2017 | 1/11/2017 | 1/11/2017 | P | PASS |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
Issue PAID IN FULL permit | | | 1/6/2017 | | DONE |
|
|
|
|
OVERRIDE | | | 12/28/2016 | | |
|
|
|
|
Plan assigned to (BJM) | 12/22/2016 | 12/22/2016 | 12/28/2016 | | DONE |
Brian McGowan
|
|
|
12/21
|
1st review completed | | | 12/28/2016 | | DONE |
Brian McGowan
|
|
|
|
Case Summary (BLD) | | | 12/28/2016 | | DONE |
Brian McGowan
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 12/28/2016 | | DONE |
Brian McGowan
|
|
|
|
Permit Ready to Issue | | | 12/28/2016 | | DONE |
|
|
|
All Met
|
Inspection Record Card- Bld | | | 12/28/2016 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 12/12/2016 | | 12/28/2016 | | PASS |
Brian McGowan
|
|
|
|
Plan assigned to (LEG) Tisha | 12/8/2016 | | 12/22/2016 | | DEFR |
Tisha Gallop
|
|
|
12/21
|
Routing - MECHANICAL | 12/9/2016 | | 12/13/2016 | | PASS |
Troy James
|
|
|
|
Routing - PLANNING | 12/8/2016 | | 12/9/2016 | | PASS |
Sue Cummings
|
|
|
|
Routing - Addressing | 12/8/2016 | | 12/8/2016 | | PASS |
Laura Hunter
|
|
|
|
Routing - PUBLIC WORKS | 12/8/2016 | | 12/8/2016 | | PASS |
Rachael Beierle
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 12/8/2016 | | DONE |
|
|
|
|
Intake Approval | | | 12/8/2016 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 12/8/2016 | | DONE |
|
|
|
|
Application received | | 12/8/2016 | | | |
|
|
|
|