BLD-Final | 7/11/2018 | 7/11/2018 | 7/11/2018 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown
|
DOC - Permit Finaled | 7/11/2018 | 7/11/2018 | 7/11/2018 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Blower Door Test Results | 7/11/2018 | 7/11/2018 | 7/11/2018 | P | DONE |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown.
6.6ACH@50pca
|
BLD-Energy code compliance | 2/15/2018 | 2/15/2018 | 2/15/2018 | A | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown
|
BLD-Framing/Rough-in | 2/15/2018 | 2/15/2018 | 2/15/2018 | A | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown
|
BLD-Energy code compliance | 2/12/2018 | 2/12/2018 | 2/12/2018 | P | NR |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown
|
BLD-Framing/Rough-in | 2/12/2018 | 2/12/2018 | 2/12/2018 | P | NR |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown
|
BLD-Framing/Rough-in | 2/5/2018 | 2/5/2018 | 2/5/2018 | P | FAIL |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown. Strap all top plate and bottom plate breaks. Fire block all fur outs and fur downs. repair top chord break in floor joist in garage. Fur out walls at stairs in garage for R-19 insulation. Ok to insulate.
|
BLD-Wall Bracing | 11/30/2017 | 11/30/2017 | 11/30/2017 | P | PASS |
Mike Jordan
|
|
|
Shear // Sam Phone #: ###-####
|
BLD-Other | 10/13/2017 | 10/13/2017 | 10/13/2017 | P | PASS |
Mike Jordan
|
|
|
Requests late afternoon for rebar - Sam Phone #: ###-####
|
BLD-Foundation | 9/28/2017 | 9/28/2017 | 9/28/2017 | P | PASS |
Mike Jordan
|
|
|
Insulation // Sam Phone #: ###-####
|
BLD-Foundation | 9/26/2017 | 9/26/2017 | 9/26/2017 | P | PASS |
Brandon Shaw
|
|
|
Manuel Phone #: ###-####
|
BLD-Footing | 9/25/2017 | 9/25/2017 | 9/26/2017 | P | PASS |
Brandon Shaw
|
|
|
Manuel Phone #: ###-####
|
Issue PAID IN FULL permit | | | 9/12/2017 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 9/12/2017 | | DONE |
|
|
|
|
OVERRIDE | | | 9/6/2017 | | |
|
|
|
|
Permit Ready to Issue | | | 9/6/2017 | | DONE |
|
|
|
all met
|
Plan assigned to (BJM) | 3/2/2017 | 3/2/2017 | 9/1/2017 | | DONE |
Brian McGowan
|
|
|
2nd review 8/29; 1st Review Complete -Due 3-17 Level 2 - Fail -Wrong plans uploaded for proposed Site Plan.
|
Routing - PLAN CHECK | 9/1/2017 | | 9/1/2017 | | PASS |
Brian McGowan
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 9/1/2017 | | DONE |
Brian McGowan
|
|
|
|
Routing - PLAN CHECK | 8/22/2017 | | 8/29/2017 | | FAIL |
Brian McGowan
|
|
|
upper P5 side wall/roof not match lower level, wrong main and upper floor plans uploaded.
|
Plan resubmittals received | | | 8/22/2017 | | DONE |
|
|
|
|
Routing - PLANNING | 2/28/2017 | | 7/6/2017 | | PASS |
Cody Riddle
|
|
|
|
Extend Review Timeline | | | 6/5/2017 | | DONE |
|
|
|
1st approved 180 day extension per Adele. See documents
|
Expiration Notice | 5/18/2017 | 6/9/2017 | 5/18/2017 | | DONE |
Brittany Hill
|
|
|
|
1st review completed | | | 3/20/2017 | | FAIL |
Brian McGowan
|
|
|
Wrong plans uploaded for proposed Site Plan.
|
Routing - PLAN CHECK | 2/28/2017 | | 3/20/2017 | | FAIL |
Brian McGowan
|
|
|
Wrong plans uploaded for proposed Site Plan.
|
Route to Impact Fee Review | 2/28/2017 | 3/3/2017 | 3/6/2017 | | PASS |
Tonya Wallace
|
|
|
Initial residential review of all new news permit requested for now.
|
Plan assigned to (LEG) Tisha | 2/28/2017 | | 3/2/2017 | | DEFR |
Tisha Gallop
|
|
|
|
Routing - Addressing | 2/28/2017 | | 3/1/2017 | | PASS |
Laura Hunter
|
|
|
|
Routing - PUBLIC WORKS | 2/28/2017 | | 2/28/2017 | | PASS |
Morgan Webb
|
|
|
|
Routing - MECHANICAL | 2/28/2017 | | 2/28/2017 | | PASS |
Troy James
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 2/28/2017 | | DONE |
Christina Prado
|
|
|
|
Intake Approval | | | 2/28/2017 | | PASS |
Christina Prado
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 2/28/2017 | | DONE |
Christina Prado
|
|
|
|
Application received | | | 12/13/2016 | | DONE |
|
|
|
Application submitted via PDS Online on Dec 13 2016 12:04PM
|