BLD-Final | 9/12/2017 | 9/13/2017 | 9/13/2017 | P | PASS |
Tony Young
|
|
|
Dan Phone #: ###-#### Inspection requested via web by Daniel Appel
|
DOC - Permit Finaled | 9/13/2017 | 9/13/2017 | 9/13/2017 | P | PASS |
Tony Young
|
|
|
c of o issued
|
BLD-Final | 9/5/2017 | 9/6/2017 | 9/6/2017 | A | NR |
Tony Young
|
|
|
Call for garage code - Dan Phone #: ###-####,, conf only
|
PubWorks Occupancy Approval | 9/5/2017 | 9/5/2017 | 9/5/2017 | | DONE |
Jason C. Taylor
|
|
|
Final elevation certificate recieved and approved. JCT
|
BLD-Foundation | 7/17/2017 | 7/18/2017 | 7/18/2017 | P | DONE |
Tony Young
|
|
|
Dane Phone #: ###-####
|
BLD-Footing | 7/14/2017 | 7/17/2017 | 7/17/2017 | P | PART |
Tony Young
|
|
|
Dane Phone #: ###-####,, porch foundation,, poured
|
BLD-Footing | 7/13/2017 | 7/14/2017 | 7/14/2017 | P | NR |
Tony Young
|
|
|
Jerry Phone #: ###-####
|
BLD-Footing | 7/12/2017 | 7/13/2017 | 7/13/2017 | P | NR |
Tony Young
|
|
|
Dane Phone #: ###-####
|
BLD-Footing | 7/11/2017 | 7/12/2017 | 7/12/2017 | P | NR |
Tony Young
|
|
|
Dane Phone #: ###-####
|
BLD-Energy code compliance | 5/31/2017 | 6/1/2017 | 6/1/2017 | A | PASS |
Tony Young
|
|
|
Mid pm please Dan Phone #: ###-#### Inspection requested via web by Daniel Appel
|
BLD-Energy code compliance | 5/30/2017 | 5/31/2017 | 6/1/2017 | P | NR |
Tony Young
|
|
|
Mid pm please Dan Phone #: ###-#### Inspection requested via web by Daniel Appel
|
BLD-Wall cover | 5/30/2017 | 5/31/2017 | 5/31/2017 | P | PART |
Tony Young
|
|
|
Mid pm please Dan Phone #: ###-#### Inspection requested via web by Daniel Appel// work in progress,, ok
|
BLD-Framing/Rough-in | 5/25/2017 | 5/25/2017 | 5/25/2017 | P | PASS |
Tony Young
|
|
|
Dan Phone #: ###-####
|
BLD-Framing/Rough-in | 5/24/2017 | 5/25/2017 | 5/25/2017 | A | DEFR |
Tony Young
|
|
|
Dan Phone #: ###-####, needs mech 1st
|
BLD-Wall Bracing | 5/12/2017 | 5/12/2017 | 5/12/2017 | P | PART |
Jim Sly
|
|
|
Shear // Dan Phone #: ###-#### Exterior Shear Nailing Only....OK. Check Shear panel N.of Garage doors. Required HD9B's (2) attached to 3 studs. (not installed yet). panel nailing 8d at 4/12.
|
Elevation Cert Rec'd-Midconst | | | 5/1/2017 | | DONE |
|
|
|
|
BLD-Energy code compliance | 3/31/2017 | 4/3/2017 | 4/3/2017 | A | PASS |
Mike Jordan
|
|
|
Dan Phone #: ###-####. Rigid insulation on stemwall under slab on grade.
|
Override - Condition Holds | 3/31/2017 | 1/1/1900 | 3/31/2017 | | |
|
|
|
energy
|
BLD-Foundation | 3/27/2017 | 3/28/2017 | 3/28/2017 | P | PART |
Tony Young
|
|
|
Dane Phone #: ###-####,, work in progress
|
BLD-Footing | 3/24/2017 | 3/27/2017 | 3/27/2017 | P | PART |
Tony Young
|
|
|
Dane Phone #: ###-####,, work in progress,, ok
|
Override - Condition Holds | 3/27/2017 | 1/1/1900 | 3/27/2017 | | |
|
|
|
foundation
|
BLD-Footing | 3/23/2017 | 3/24/2017 | 3/24/2017 | P | NR |
Tony Young
|
|
|
Dane Phone #: ###-####
|
BLD-Footing | 3/22/2017 | 3/23/2017 | 3/23/2017 | P | NR |
Tony Young
|
|
|
Dane Phone #: ###-####
|
BLD-Footing | 3/21/2017 | 3/22/2017 | 3/22/2017 | P | NR |
Dave Hannah
|
|
|
Phone #: ###-#### no one on site on forms ect
|
Override - Condition Holds | 3/22/2017 | 1/1/1900 | 3/22/2017 | | |
|
|
|
footing
|
Override - Condition Holds | 3/21/2017 | 1/1/1900 | 3/21/2017 | | |
|
|
|
foundation
|
Inspection Record Card- Bld | | | 3/21/2017 | | DONE |
|
|
|
|
Override - Condition Holds | | | 3/21/2017 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 3/21/2017 | | DONE |
|
|
|
|
OVERRIDE | | | 2/23/2017 | | |
|
|
|
|
Elevation Cert Rec'd-Prelim | | | 2/23/2017 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 2/23/2017 | | DONE |
|
|
|
|
Override - Condition Holds | | | 2/23/2017 | | |
|
|
|
|
Permit Ready to Issue | | | 2/23/2017 | | DONE |
|
|
|
All Met
|
Plan assigned to (LEG) Tisha | 1/12/2017 | | 2/23/2017 | | DONE |
Tisha Gallop
|
|
|
1st review 1/27 (floodplain, planning & plan check (see changemarks) L2 floodplain
|
Routing PW Flood Plain | 2/21/2017 | | 2/22/2017 | | PASS |
Jim Wyllie
|
|
|
Two more elevation Cetificates are required: One prior to receiving a framing inspection and one based upon finished construction.
Jim Wyllie / ###-####
|
Plan resubmittals received | | | 2/21/2017 | | DONE |
|
|
|
via e-mail addressing building comments. uploaded by LEG
|
Routing - PLAN CHECK | 2/21/2017 | | 2/21/2017 | | PASS |
Tisha Gallop
|
|
|
|
Plan resubmittals received | | | 2/21/2017 | | DONE |
|
|
|
|
Routing PW Flood Plain | 2/9/2017 | | 2/15/2017 | | FAIL |
Jim Wyllie
|
|
|
per e-plan
|
Routing - PLAN CHECK | 2/9/2017 | | 2/10/2017 | | FAIL |
Tisha Gallop
|
|
|
|
Plan resubmittals received | | | 2/8/2017 | | DONE |
|
|
|
|
1st review completed | | | 1/31/2017 | | FAIL |
|
|
|
pending approval from plan check and floodplain
|
Routing PW Flood Plain | 1/12/2017 | | 1/30/2017 | | FAIL |
Jim Wyllie
|
|
|
Plans do not meet requirements of Floodplain Ordinance.
Jim Wyllie / ###-####
|
Routing - PLAN CHECK | 1/12/2017 | | 1/27/2017 | | FAIL |
Tisha Gallop
|
|
|
see changemarks
|
Routing - MECHANICAL | 1/12/2017 | | 1/12/2017 | | PASS |
Troy James
|
|
|
|
Routing - PLANNING | 1/12/2017 | | 1/12/2017 | | PASS |
Sue Cummings
|
|
|
Issues resolved SC
|
Routing - Addressing | 1/12/2017 | | 1/12/2017 | | PASS |
Laura Hunter
|
|
|
|
Routing - PUBLIC WORKS | 1/12/2017 | | 1/12/2017 | | PASS |
Rachael Beierle
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 1/12/2017 | | DONE |
|
|
|
|
Intake Approval | | | 1/12/2017 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 1/12/2017 | | DONE |
|
|
|
|
Intake Approval | | | 1/11/2017 | | FAIL |
Christina Prado
|
|
|
Need Stair section, rescheck and garage square footage
|
Application received | | | 1/9/2017 | | DONE |
|
|
|
Application submitted via PDS Online on Jan 9 2017 3:07PM
|