Permit Information
Permit NumberBLD17-00222
StatusFinaled
Name PANORAMA CONSTRUCTION
Site Address 9931 W CABLE CAR ST Unit: 110
Project NameGrowlers
Customer Number 
ePlanReviewYes
Description
(GROWLERS – RESTAURANT – EAST END OF THE BUILDING) The fire sprinkler system is used for occupancy, for building area increase, and for fire flow. To construct interior improvements for a new 3,500 square foot restaurant and bar. Work is to include a concrete slab on grade, interior nonbearing walls, two restrooms accessible to the disabled, suspended acoustical ceilings, gypsum board ceilings, kitchen equipment, a Type I grease hood and duct system, wall insulation, attic insulation, and finishes. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. Separate fire sprinkler permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 7/22/20178/10/2017 DONE
Mailed 8-11-17
First Notice 6/17/20177/12/2017 DONE
Mailed 7-13-17
Permanent Occupancy  6/7/2017 DONE
BLD-Final6/2/20176/5/20176/5/2017PPASS
DetailsMike Jordan
Jeff Phone #: ###-####. Ok for perm occ.
FIRE-Final Inspection6/2/20176/5/20176/5/2017APASS
DetailsTroy Cobbley
life safety passed
BLD-Final5/23/20175/23/20175/23/2017PPART
DetailsMike Jordan
jeff Phone #: ###-####. All isues resolved. ok for temp occ. will be ok for perm occ. once fire/life/safety signs perm.
Temporary Occupancy5/23/20178/21/20175/23/2017 DONE
DetailsCandy A. Nichols
BLD-Final5/19/20175/22/20175/22/2017APART
DetailsMike Jordan
Jeff Phone #: ###-####. Lower bathroom lavs to 34 inch max height. Provide ADA POS. ok for temp occ. when zoning signs off. (Needs two bushes at drive thru, being planted when on site.)
FIRE-Final Inspection5/19/20175/22/20175/22/2017APART
DetailsTroy Cobbley
A temporary occupancy is being given with Scotts permission. I was given a list of trained/fire watch employees and the fire alarm permit has been submitted.

Jeff Phone #: ###-####
Zoning Approval5/22/20175/22/20175/22/2017 PASS
DetailsSusan Riggs
FIRE-Final Inspection5/19/20175/19/20175/19/2017PFAIL
DetailsTroy Cobbley
Need the exit discharge lights repaired and a list of employees who are responcible for the fire watch. When they are repaired and list is provided and the fire alarm permit is submitted, per Scott, the project can have a temporary until the interconnect of the kitchen hood suppression system and the two AHU's has been tested.

Jeff Phone #: ###-####
CHANGE STATUS TO (ISS)  5/19/2017 DONE
plan mod paid
OVERRIDE  4/13/2017  
Plan assigned to (CJW)4/12/20174/12/20174/13/2017 PASS
DetailsCarl Westfall
Routing - PLAN CHECK4/13/2017 4/13/2017 PASS
DetailsCarl Westfall
1st plan mod completed
Plan Modification Accepted  4/13/2017 DONE
Work flow in ePlanReview received
Plan Reviewer's activity  4/13/2017 DONE
1st plan mod approved and routed to the permits desk.
Permit Ready to Issue  4/13/2017 DONE
PLEASE do not re issue
BLD-Energy code compliance4/12/20174/12/20174/12/2017PPASS
DetailsMike Jordan
BLD-Framing/Rough-in4/11/20174/12/20174/12/2017APASS
DetailsMike Jordan
Jeff Phone #: ###-####
Plan Modification Accepted  4/12/2017 DONE
DetailsChristina Prado
Plan Mod to remove FA system, reduce the fire rating in demising wall and extend fire sprinkler system
BLD-Framing/Rough-in4/11/20174/11/20174/11/2017PPART
DetailsMike Jordan
ok to insulate.
BLD-Framing/Rough-in4/10/20174/10/20174/10/2017PNR
DetailsMike Jordan
Jeff Phone #: ###-####. ok to insulate exterior walls. Provide city set of approved plans.
Issue PAID IN FULL permit  4/7/2017 DONE
Print Occupancy Form  4/7/2017 DONE
OVERRIDE  4/6/2017  
Plan assigned to (CJW)2/15/20172/15/20174/6/2017 PASS
DetailsCarl Westfall
(3rd done) (Mar 7 - 15 days) (24 sheets) Growlers
Routing - MECHANICAL4/5/2017 4/6/2017 PASS
DetailsTroy James
Please copy your redlines to the latest version
Routing - PLUMBING4/5/2017 4/6/2017 PASS
DetailsBill VanDegrift
per plans and ISPC. additional cross connection protection may be required
Routing PW Sewer Rating4/5/2017 4/6/2017 PASS
DetailsRachael Beierle
Toilet and sink removed. making space into storage. no new customer area. no change in permit.
PLANS/APPL TAKEN TO FRONT DESK  4/6/2017 DONE
Permit Ready to Issue  4/6/2017 DONE
***all requirements met 4-7-17 /CEV

***still needs RP 4-7-17 /CEV

need GC, RP & rev cert of val
Routing - PLAN CHECK4/4/2017 4/5/2017 PASS
DetailsCarl Westfall
3rd review approved
Plan resubmittals received  4/4/2017 DONE
Routing - PLAN CHECK3/30/2017 4/3/2017 FAIL
DetailsCarl Westfall
Routing - PLUMBING3/30/2017 4/3/2017 FAIL
DetailsBill VanDegrift
address change marks
Plan resubmittals requested  4/3/2017 DONE
Plan resubmittals received  3/30/2017 DONE
Route to Impact Fee Review3/15/20173/18/20173/16/2017 PASS
DetailsTonya Wallace
Review requested for Commercial Permit
1st review completed  3/15/2017 DONE
Plan resubmittals requested  3/15/2017 DONE
Routing - PLAN CHECK2/15/2017 3/15/2017 FAIL
DetailsCarl Westfall
Routing PW Environmental2/15/2017 2/21/2017 PASS
DetailsRick Christenson
Routing - Erosion and Sediment2/15/2017 2/17/2017 PASS
DetailsMelissa Jannusch
Level 3 TI. ESC plan waiver
Routing - FIRE2/15/20172/15/20172/16/2017 PASS
DetailsKatie Marron
comments attached to case.
Routing - MECHANICAL2/15/2017 2/16/2017 PASS
DetailsTroy James
Routing - PLUMBING2/15/2017 2/16/2017 FAIL
DetailsBill VanDegrift
1) prep sinks must be indirectly wasted

2) IDAPA 07.02.06.20-- dishwasher must be indirectly wasted.
Routing - PLANNING2/15/2017 2/15/2017 PASS
DetailsCody Riddle
Allowed per use exception.
Routing - Addressing2/15/2017 2/15/2017 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS2/15/2017 2/15/2017 PASS
DetailsRachael Beierle
REQUESTED MENU 02-15-2017 FROM CONNIE VIA PHONE
Intake Approval  2/15/2017 PASS
DetailsDavid Ferguson
CHD approved signed app uploaded in documents in e plan
Intake Approval  2/10/2017 FAIL
DetailsDavid Ferguson
Need #520 Checklist (Vanilla build-out into restaurant)
Naming Convention not followed
Plan sheets say "Preliminary Design / Not For Construction
Intake Approval  2/10/2017 FAIL
DetailsDavid Ferguson
1) Need fire flow letter from Suez Water
2) You've indicated on your checklist that information can be found on pages A.100 and A.601. These pages are not included in you submittal documents. Please include these pages on your resubmittal or revise the checklist to indicate the correct page number.
Application received  2/8/2017 DONE
Application submitted via PDS Online on Feb 8 2017 9:48AM