BLD-Final | 6/8/2017 | 6/8/2017 | 6/8/2017 | P | PASS |
Dave Hannah
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez
|
DOC - Permit Finaled | 6/8/2017 | 6/8/2017 | 6/8/2017 | P | PASS |
Dave Hannah
|
|
|
|
BLD-Energy code compliance | 4/27/2017 | 4/28/2017 | 4/28/2017 | A | PASS |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez
|
BLD-Framing/Rough-in | 4/28/2017 | 4/28/2017 | 4/28/2017 | A | PASS |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez
|
BLD-Framing/Rough-in | 4/26/2017 | 4/27/2017 | 4/27/2017 | A | FAIL |
Mike Jordan
|
|
|
As early as possible Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Disregard previous framing inspection, done on wrong house. Complete lateral bracing on A02 trusses. Nail off all simpson hangars. Fireblock behind tub in masterbedroom. Repair bottom plate in master bedroom. Strap double top plates at peak on racked walls. Noted several studs in racked walls cut to short.-replace. Ok to insulate. Correction notice posted.
|
BLD-Framing/Rough-in | 4/26/2017 | 4/26/2017 | 4/26/2017 | P | FAIL |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Needs to complete foam seal prior to framing inspection. Roll block floor joist at glulam in garage. Provide anchor bolts in garage on bearing wall. Correction notice posted.
|
BLD-Wall cover | 4/13/2017 | 4/13/2017 | 4/13/2017 | P | PART |
Mike Jordan
|
|
|
Nate Phone #: ###-####. Exterior wall bracing ok. Did note some tore OSB from crane that needs to be removed and replaced. Noted to framers on site that wall bracing is ok, but to replace OSB and will check on framing inspection.
|
BLD-Wall Bracing | 4/12/2017 | 4/12/2017 | 4/12/2017 | P | NR |
Mike Jordan
|
|
|
Shear // Zane Phone #: ###-####
|
BLD-Foundation | 3/28/2017 | 3/28/2017 | 3/28/2017 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Footing | 3/28/2017 | 3/28/2017 | 3/28/2017 | P | PASS |
Mike Jordan
|
|
|
Footing Inspection was completed by #316, but was entered under wrong permit number (12447 W. Irving)
|
BLD-Foundation | 3/22/2017 | 3/22/2017 | 3/22/2017 | P | CANC |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
Issue PAID IN FULL permit | | | 3/21/2017 | | DONE |
|
|
|
|
OVERRIDE | | | 3/17/2017 | | |
|
|
|
|
Inspection Record Card- Bld | | | 3/17/2017 | | DONE |
|
|
|
|
Telephone call | | | 3/17/2017 | | DONE |
|
|
|
Left a message for Tom informing him that this permit is ready to be pick up and the fee amount due.
|
Plan assigned to (LEG) Tisha | 3/3/2017 | | 3/17/2017 | | DONE |
Tisha Gallop
|
|
|
3/16
|
Routing - PLAN CHECK | 3/9/2017 | | 3/17/2017 | | PASS |
Tisha Gallop
|
|
|
|
Case Summary (BLD) | | | 3/17/2017 | | DONE |
|
|
|
|
1st review completed | | | 3/17/2017 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/17/2017 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 3/17/2017 | | DONE |
|
|
|
MET
|
Routing - MECHANICAL | 3/6/2017 | | 3/9/2017 | | PASS |
Troy James
|
|
|
|
Route to Impact Fee Review | 3/3/2017 | 3/6/2017 | 3/6/2017 | | PASS |
Tonya Wallace
|
|
|
Initial residential review of all new news permit requested for now.
|
Routing - PLANNING | 3/3/2017 | | 3/6/2017 | | PASS |
Colleen T Carroll
|
|
|
|
Routing - Addressing | 3/3/2017 | | 3/3/2017 | | PASS |
Laura Hunter
|
|
|
|
Routing - PUBLIC WORKS | 3/3/2017 | | 3/3/2017 | | PASS |
Rachael Beierle
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 3/3/2017 | | DONE |
|
|
|
|
Intake Approval | | | 3/3/2017 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 3/3/2017 | | DONE |
|
|
|
|
Application received | | 3/3/2017 | | | |
|
|
|
|