Information based on query as of Thursday, July 4, 2024.
Permit Information
Permit NumberBLD17-00554
StatusFinaled
Name PRESTIGE HOMES INC
Site Address 2685 S GATEWOOD LN
Project Name 
Customer Number 
ePlanReviewNo
Description
Floodplain; Permit for the construction of a new 1702 sq. ft., one story townhouse with 3 bedrooms, 2 bathrooms, approximately 197 sq. ft. of covered patio/porch and a 535 sq. ft. attached garage per the approved plans, engineering, ACCA report and any notations. R-1A zoning and setbacks per planning.//leg
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/7/20185/8/20185/8/2018APASS
DetailsMike Jordan
Garage code 0813. Momentum sticker is on electrical panel Phone #: ###-#### Inspection requested via web by Scott Zierler
BLD-Blower Door Test Results5/8/20185/8/20185/8/2018ADONE
DetailsMike Jordan
Garage code 0813. Momentum sticker is on electrical panel Phone #: ###-#### Inspection requested via web by Scott Zierler.
4.6
DOC - Permit Finaled5/8/20185/8/20185/8/2018PPASS
DetailsMike Jordan
BLD-Framing/Rough-in1/4/20181/5/20181/5/2018APASS
DetailsMike Jordan
Thanks. Scott Phone #: ###-#### Inspection requested via web by Scott Zierler
BLD-Energy code compliance1/5/20181/5/20181/5/2018APASS
DetailsMike Jordan
Thanks. Scott Phone #: ###-#### Inspection requested via web by Scott Zierler
BLD-Energy code compliance12/28/201712/29/20171/2/2018PNR
DetailsJim Sly
Thanks. Phone #: ###-#### Inspection requested via web by Scott Zierler
Recall for Conference....inspection.
BLD-Framing/Rough-in12/28/201712/28/201712/28/2017PPART
DetailsMike Jordan
Thanks Phone #: ###-#### Inspection requested via web by Scott Zierler. Ok to insulate. All framing issues not resolved. Contractor to schedule conferance.
BLD-Framing/Rough-in12/22/201712/27/201712/27/2017ANR
DetailsMike Jordan
Reinspection. I will be out of town, but can receive text messages. Thank you. Scott. Phone #: ###-#### Inspection requested via web by Scott Zierler
BLD-Energy code compliance12/24/201712/26/201712/26/2017ACANC
DetailsBrandon Shaw
Thanks Mike. Phone #: ###-#### Inspection requested via web by Scott Zierler
BLD-Framing/Rough-in12/20/201712/21/201712/21/2017PFAIL
DetailsMike Jordan
Plans and truss engineering above the fireplace. Thanks. Phone #: ###-#### Inspection requested via web by Scott Zierler. Provide strng back on A6 gable end truss. Insufficient bearing on A5 trusses at east interior bearing wall. Remove all roof penetrations from laydown parapet. Nail off all hangers. Bottom chords on 2ply B3 truss not in contact. 2 hr. wall not continous and not to bottom of roof deck. Correction notice posted.
BLD-Other12/5/201712/8/201712/8/2017PPASS
DetailsBrandon Shaw
Soffits
BLD-Wall Bracing11/16/201711/17/201711/17/2017APASS
DetailsMike Jordan
scott Phone #: ###-####
BLD-Wall cover11/1/201711/2/201711/2/2017PCANC
DetailsMike Jordan
Common wall - Scott Phone #: ###-####. INspection completed yesterday.
Routing PW Flood Plain9/27/2017 9/27/2017 PASS
DetailsJason C. Taylor
Two Elevation Certificates will be required; one prior to receiving a framing inspection, and one based upon finished construction. These certificates will need to be reviewed and approved by Public Works staff prior to occupancy approval. Jason Taylor ###-####
Elevation Cert Rec'd-Midconst  9/27/2017 DONE
BLD-Foundation8/28/20178/29/20178/29/2017PPASS
DetailsBrandon Shaw
Ricardo Phone #: ###-####
BLD-Footing8/28/20178/28/20178/28/2017PPASS
DetailsBrandon Shaw
Ron Phone #: ###-####
Override - Condition Holds8/28/20171/1/19008/28/2017  
not framing
Override - Condition Holds  4/25/2017  
Issue PAID IN FULL permit  4/25/2017 DONE
OVERRIDE  4/13/2017  
Telephone call  4/13/2017 DONE
notified customer that permit is ready
Case Summary (BLD)  4/13/2017 DONE
Routing - PLAN CHECK4/13/2017 4/13/2017 PASS
DetailsTisha Gallop
PLANS/APPL TAKEN TO FRONT DESK  4/13/2017 DONE
Inspection Record Card- Bld  4/13/2017 DONE
DetailsChristina Prado
Override - Condition Holds  4/13/2017  
Permit Ready to Issue  4/13/2017 DONE
DetailsChristina Prado
All requirements met
Plan assigned to (LEG) Tisha3/9/2017 4/13/2017 DONE
DetailsTisha Gallop
1st review 3/29; plan check
Plan resubmittals received  4/11/2017 DONE
Two copies of Rescheck, Lateral Design packet and sheets A-2, A-3 and A-3a. Taken to Tisha
Routing - PLAN CHECK3/14/2017 3/29/2017 FAIL
DetailsTisha Gallop
1st review completed  3/29/2017 FAIL
Routing PW Flood Plain3/10/2017 3/15/2017 PASS
DetailsJim Wyllie
Elevation Cert Rec'd-Prelim  3/15/2017  
Routing - MECHANICAL  3/14/2017 PASS
DetailsTroy James
Route to Impact Fee Review3/9/20173/12/20173/13/2017 PASS
DetailsTonya Wallace
Initial residential review of all new news permit requested for now.
Routing - PLANNING3/10/2017 3/10/2017 PASS
DetailsSue Cummings
Routing - Addressing3/9/2017 3/9/2017 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS3/9/2017 3/9/2017 PASS
DetailsMorgan Webb
Plans ACCEPTED BY PLAN TECH  3/9/2017 DONE
Intake Approval  3/9/2017 PASS
Recd Pcfee & Taken To Pln CK  3/9/2017 DONE
Application received 3/9/2017