BLD-Final | 5/16/2018 | 5/18/2018 | 5/18/2018 | A | PASS |
Jim Storey
|
|
|
Swimming Pool Final Inspection Phone #: ###-#### Inspection requested via web by Brandy McConkey as noted
|
DOC - Permit Finaled | 5/18/2018 | 5/18/2018 | 5/18/2018 | P | PASS |
Jim Storey
|
|
|
gates anchored closed only access alarmed house barrior.
|
BLD-Final | 4/11/2018 | 4/13/2018 | 4/16/2018 | A | FAIL |
Jim Storey
|
|
|
Swimming Pool Final Inspection Phone #: ###-#### Inspection requested via web by Brandy McConkey8. Access gates shall comply with the requirements of Items 1 through 7, and shall be equipped to accommodate a locking device. Pedestrian access gates shall open outward away from the pool, and shall be self-closing and have a self-latching device. Gates, other than pedestrian access gates, shall have a self-latching device. Where the release mechanism of the self-latching device is located less than 54 inches (1372 mm) from the bottom of the gate, the release mechanism and openings shall comply with the following:
8.1. The release mechanism shall be located on the pool side of the gate at least 3 inches (76 mm) below the top of the gate; and
8.2. The gate and barrier shall have no opening larger than 1/2 inch (12.7 mm) within 18 inches (457 mm) of the release mechanism.
|
BLD-Aging Inspection | 10/6/2017 | 10/6/2017 | 10/6/2017 | | PEND |
Jim Storey
|
|
|
ncfi/no mech
|
BLD-Foundation | 5/23/2017 | 5/24/2017 | 5/24/2017 | A | PASS |
Jim Storey
|
|
|
Brandy-steel rebar Phone #: ###-####
|
OVERRIDE | | | 4/5/2017 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 4/5/2017 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 4/5/2017 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 4/5/2017 | | DONE |
|
|
|
***met 4-5-17 CAN***need GC and RP
|
Plan assigned to (JG) | 4/4/2017 | 4/4/2017 | 4/4/2017 | | PASS |
Javier Guzman
|
|
|
|
Plan assigned to (BJM) | 3/20/2017 | 3/20/2017 | 4/4/2017 | | DEFR |
Brian McGowan
|
|
|
|
Routing - PLAN CHECK | 3/20/2017 | | 4/4/2017 | | PASS |
Javier Guzman
|
|
|
|
1st review completed | | | 4/4/2017 | | DONE |
Javier Guzman
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 4/4/2017 | | DONE |
|
|
|
|
Application received | | | 3/20/2017 | | DONE |
|
|
|
Application submitted via PDS Online on Mar 20 2017 1:30PM
|
Plans ACCEPTED BY PLAN TECH | | | 3/20/2017 | | DONE |
|
|
|
|
Intake Approval | | | 3/20/2017 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 3/20/2017 | | DONE |
|
|
|
no fees taken at intake
|
Routing - PLANNING | 3/20/2017 | | 3/20/2017 | | PASS |
Sue Cummings
|
|
|
|