Meeting | | | 5/11/2018 | | DONE |
|
|
|
sent statement 5-14
|
Print Statement | | | 3/5/2018 | | DONE |
|
|
|
|
Third Notice | | 1/17/2018 | 2/12/2018 | | DONE |
|
|
|
|
Third Notice | | 12/17/2017 | 1/12/2018 | | DONE |
|
|
|
Mailed 1-12-18
|
Third Notice | | 11/19/2017 | 12/12/2017 | | DONE |
|
|
|
Mailed 12-14-17
|
PubWorks Occupancy Approval | 11/28/2017 | 11/28/2017 | 11/28/2017 | | DONE |
Tiffany Lowery
|
|
|
|
Second Notice | | 10/22/2017 | 11/14/2017 | | DONE |
|
|
|
Mailed 11-15-17
|
First Notice | | 10/1/2017 | 10/12/2017 | | DONE |
|
|
|
Mailed 10-13-17
|
Permanent Occupancy | | | 9/21/2017 | | DONE |
|
|
|
|
BLD-Final | 9/8/2017 | 9/8/2017 | 9/8/2017 | P | PASS |
Mike Jordan
|
|
|
Ok for temp occ. Will be ok for perm. occ. once electrical signs perm.
|
Temporary Occupancy | 9/8/2017 | 12/7/2017 | 9/8/2017 | | DONE |
Christina Prado
|
|
|
|
Zoning Approval | 9/8/2017 | 9/8/2017 | 9/8/2017 | | PASS |
Sarah Schafer
|
|
|
|
BLD-Final | 9/6/2017 | 9/7/2017 | 9/7/2017 | P | NR |
Mike Jordan
|
|
|
Mike Phone #: ###-####. Needs zoning final.
|
FIRE-Final Inspection | 9/6/2017 | 9/7/2017 | 9/7/2017 | A | PASS |
Troy Cobbley
|
|
|
Life safety passed.
|
BLD-Foundation | 7/10/2017 | 7/11/2017 | 7/11/2017 | A | PART |
Mike Jordan
|
|
|
Call 30 mins ahead for access-Jeremy Phone #: ###-####. Work in progress. All steel in place. insatlling forms. Special inspector will be on site to check final clearances prior to placement.
|
BLD-Foundation | 6/29/2017 | 6/30/2017 | 6/30/2017 | A | PASS |
Mike Jordan
|
|
|
Jeremy Phone #: ###-####. North concrete shed wall. ok for concrete.
|
BLD-Foundation | 6/28/2017 | 6/29/2017 | 6/29/2017 | P | DEFR |
Mike Jordan
|
|
|
Please call 30min ahead for access - Jeremy Phone #: ###-####. Moved to a.m. inspection on 7-30.
|
BLD-Footing | 6/16/2017 | 6/19/2017 | 6/19/2017 | P | PASS |
Mike Jordan
|
|
|
Jeremy Phone #: ###-####. All issues have been resolved. ok to place concrete. Special inspection ok for reinforcement. Will have special inspection for concrete.
|
BLD-Footing | 6/12/2017 | 6/13/2017 | 6/13/2017 | P | FAIL |
Jim Storey
|
|
|
Jeremy Phone #: ###-#### need engineer site evalueation of soil and water to how and when to place pending mti rebar aproval.
|
OVERRIDE | | | 5/3/2017 | | |
|
|
|
|
Route to Impact Fee Review | 5/2/2017 | 5/5/2017 | 5/3/2017 | | PASS |
Eric Bilimoria
|
|
|
Review requested for Commercial Permit
|
Print Occupancy Form | | | 5/3/2017 | | DONE |
|
|
|
|
Telephone call | | | 5/3/2017 | | DONE |
|
|
|
called Jeremy to let know permit is ready and that we need the GC, RP & rev cert of val. Talked to his admin assis-she will let him know
|
Issue PAID IN FULL permit | | | 5/3/2017 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 5/3/2017 | | DONE |
|
|
|
**MET 5-3-17** need revised cert of value, GC form, RP
|
Plan assigned to (CDM) | 3/24/2017 | 3/24/2017 | 5/2/2017 | | PASS |
Carl D Madsen
|
|
|
pending assignment by Carl Madsen
|
Routing Off Site - STRUCTURAL | 3/28/2017 | | 5/2/2017 | | PASS |
Carl D Madsen
|
|
|
|
Routing - PLAN CHECK | 4/26/2017 | | 5/2/2017 | | PASS |
Carl D Madsen
|
|
|
|
Plan resubmittals received | | | 5/2/2017 | | DONE |
|
|
|
received two copies of MTI addeendum #1, foundation engineering calcs, steel building plans (11x17) 9 pgs, full size plan sheets F-1, F-2, F-3; taken to Carl Madsen
|
Case Summary (BLD) | | | 5/2/2017 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/2/2017 | | DONE |
|
|
|
|
Routing - FIRE | 4/24/2017 | 3/28/2017 | 4/26/2017 | | PASS |
Scott Arellano
|
|
|
One fire hydrant is being installed under this permit, to the east of the structure.
|
1st review completed | | | 4/24/2017 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 4/20/2017 | | 4/24/2017 | | PASS |
Carl D Madsen
|
|
|
|
Routing - Erosion and Sediment | | | 4/20/2017 | | PASS |
Andy J. Long
|
|
|
SWPPP/ESC plan approved. Need to designate RP from Alta Construction
|
Routing - PLANNING | 4/14/2017 | | 4/19/2017 | | PASS |
Sarah Schafer
|
|
|
Approved per DRH16-00269.
|
Routing - PUBLIC WORKS | | | 4/14/2017 | | PASS |
Rachael Beierle
|
|
|
|
Routing PW Drainage | 3/29/2017 | | 4/14/2017 | | PASS |
Brian Murphy
|
|
|
|
Routing PW Sewer Rating | 4/14/2017 | | 4/14/2017 | | PASS |
Morgan Webb
|
|
|
|
Routing PW Street Lights | 3/29/2017 | | 4/10/2017 | | PASS |
Tom Marshall
|
|
|
|
Routing - PLANNING Land Div | 3/28/2017 | | 3/29/2017 | | PASS |
Todd Tucker
|
|
|
|
Routing - Addressing | 3/29/2017 | | 3/29/2017 | | PASS |
Laura Hunter
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 3/24/2017 | | DONE |
|
|
|
|
Intake Approval | | | 3/24/2017 | | PASS |
|
|
|
as per Carl Westfall
|
Recd Pcfee & Taken To Pln CK | | | 3/24/2017 | | DONE |
|
|
|
|
Application received | | 3/23/2017 | | | |
|
|
|
|