Information based on query as of Saturday, June 29, 2024.
Permit Information
Permit NumberBLD17-00807
StatusFinaled
Name LEHMAN LEGACY CONSTRUCTON & DESIGN
Site Address 1400 S JACKSON ST
Project Name1400 S JACKSON REMODEL
Customer Number 
ePlanReview 
Description
***customer has elected to switch from online to paper submittal 3-28-17*** Expanding bedroom, relocating bathroom, and adding utility/laundry room. Permit to add 8'x24' (192 square feet) to the rear of an existing home (removing the existing Bathroom) and remodel the interior to include (2) Bedrooms, (1) Bathroom, Kitchen, Living Room and Laundry Room. No interior bearing walls are being removed. Existing rear bearing wall to be replaced with girder trusses. Smoke detectors and carbon monoxide alarms to be updated as required. Ductless heating/cooling is proposed. All work to be done according to plans, notes, review notes and local codes. **BJM**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Letter of compliance/Occupancy  10/24/2017 DONE
BLD-Final7/19/20177/20/20177/20/2017PPASS
DetailsJim Storey
AJ Phone #: ###-####
DOC - Permit Finaled7/20/20177/20/20177/20/2017PPASS
DetailsJim Storey
BLD-Framing/Rough-in6/1/20176/2/20176/2/2017PPASS
DetailsJim Storey
AJ Phone #: ###-####
Routing - MECHANICAL5/31/2017 5/31/2017 PASS
DetailsTroy James
CHANGE STATUS TO (ISS)  5/31/2017 DONE
Submitted manual j report has been approved.
BLD-Wall Bracing5/22/20175/22/20175/22/2017PPASS
DetailsJim Storey
AJ Phone #: ###-####
Routing - PLAN CHECK5/16/2017 5/17/2017 FAIL
DetailsTroy James
The manual j report is incomplete. Talked to mechanical contractor and he said that he was not done with his design. The design went from ductless to ducted system.
Plan Modification Accepted  5/16/2017 DONE
manual J's submitted-took to Troy James
BLD-Foundation4/6/20174/7/20174/7/2017APASS
DetailsJim Storey
Ardi Phone #: ###-####
BLD-Foundation4/4/20174/4/20174/4/2017PPASS
DetailsJim Storey
ARDI Phone #: ###-####
OVERRIDE  3/29/2017  
Telephone call  3/29/2017 DONE
called Monica to let know permit is ready and how much is owed
Issue PAID IN FULL permit  3/29/2017 DONE
Permit Ready to Issue  3/29/2017 DONE
MET
Routing Walk-In (Zoning)3/28/20173/28/20173/28/2017ADONE
DetailsChristina Prado
Routing Walk-In (BLD)3/28/20173/28/20173/28/2017PDONE
DetailsBrian McGowan
1st review completed  3/28/2017 DONE
DetailsBrian McGowan
Routing - PLAN CHECK3/28/2017 3/28/2017 PASS
DetailsBrian McGowan
Case Summary (BLD)  3/28/2017 DONE
DetailsBrian McGowan
Inspection Record Card- Bld  3/28/2017 DONE
DetailsBrian McGowan
PLANS/APPL TAKEN TO FRONT DESK  3/28/2017 DONE
DetailsBrian McGowan
1st review completed  3/28/2017 FAIL
DetailsBrian McGowan
Need Manual J for new furnace and duct work. They will email me the Manual J. I have the hard copy plans. Switched to ductless system.
Routing - PLAN CHECK3/28/2017 3/28/2017 FAIL
DetailsBrian McGowan
Need Manual J for new furnace and duct work. They will email me the Manual J. I have the hard copy plans. (switched to ductless system)
Meeting  3/28/2017 DONE
customer has elected to switch from online to paper submittal
Application received  3/27/2017 DONE
Application submitted via PDS Online on Mar 27 2017 2:12PM
Plans ACCEPTED BY PLAN TECH  3/27/2017 DONE
Intake Approval  3/27/2017 PASS
Recd Pcfee & Taken To Pln CK  3/27/2017 DONE
no fees taken in at submittal