Permit Information
Permit NumberBLD17-00849
StatusFinaled
Name LAYTON CONSTRUCTION
Site Address 6895 S EISENMAN RD Unit: 110
Project NamePODS
Customer Number 
ePlanReviewYes
Description
(PODS – PORTABLE SELF STORAGE CONTAINER WAREHOUSE) (DRH16-00124) (CZC17-00082) The fire sprinkler system is used for unlimited area of the building. To create a 36,243 square foot tenant space within a new 52,000 square foot building. Work is to include a tenant demising wall, suspended ceilings within the office area, gypsum board ceilings at the toilet rooms, a new 20 feet by 20 feet overhead door opening in the South exterior wall (former opening was 12 feet wide by 14 feet high), and bollards. Two existing exterior tilt-up concrete panels will be modified to accommodate the larger overhead door opening and new steel columns and beams will be installed on the inside of the wall to resist out of plane lateral loads. Steel plates will be installed to reinforce panel to panel joints above the enlarged opening. Special Inspection is required for welding and for post installed anchors in hardened concrete. The accessible restrooms and office area were constructed under shell permit BLD16-02176. The accessible drinking fountains and the service sink were also installed under that permit. A separate racking permit is required for racks over 8 feet in height. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Print Statement  7/18/2017 DONE
First Notice 6/25/20177/12/2017 DONE
Mailed 7-13-17
Permanent Occupancy  6/15/2017 DONE
Zoning Approval6/14/20176/14/20176/14/2017 DONE
DetailsAndrea Tuning
BLD-Final6/12/20176/13/20176/13/2017PPASS
DetailsJim Storey
Brent Phone #: ###-#### no racking
FIRE-Final Inspection6/12/20176/13/20176/13/2017APASS
DetailsJim Page
Fire sprinkler inspection is complete, fire alarm inspection for building is complete, fire extinguishers are in place with current inspection tags. Final life fire safety inspection passed/complete.
FIRE-Final Inspection6/8/20176/9/20176/9/2017AFAIL
DetailsTroy Cobbley
Need fire extinguisher at office and an exit sign in the office at the main entry doors, need exit signs as per plans and discussion in the warehouse area, needs missing door installed and panic hardware.
FIRE-Final Inspection6/1/20176/2/20176/2/2017PFAIL
DetailsJim Page
Fire life safety cannot be completed for this permit until the fire sprinkler/fire alarm (FIR16-00724 for fire alarm and FIR16-00705 for fire sprinkler) permits for core and shell are complete as well as the BLD (BLD16-02176) permit for core and shell is complete. After core and shell permits are passed then the FIR permit (FIR17-00190) for fire sprinklers associated with this project will need to be completed before life fire safey inspection can be performed.
BLD-Ceiling Grid Inspection5/31/20175/31/20175/31/2017PPASS
DetailsDave Hannah
Brent Phone #: ###-####
Issue PAID IN FULL permit  5/17/2017 DONE
DetailsChristina Prado
Print Occupancy Form  5/17/2017 DONE
DetailsChristina Prado
Plan assigned to (CJW)4/5/20174/5/20175/16/2017 PASS
DetailsCarl Westfall
(2nd done) (Apr 25 - 15 days) (38 sheets) PODS
Routing - PLAN CHECK5/11/2017 5/16/2017 PASS
DetailsCarl Westfall
Approved by Structural
PLANS/APPL TAKEN TO FRONT DESK  5/16/2017 DONE
Permit Ready to Issue  5/16/2017 DONE
***Met 5-16-17 can***Need GC Form and Revised Cert of Value
Route to Impact Fee Review5/11/20175/14/20175/15/2017 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - FIRE5/11/2017 5/12/2017 PASS
DetailsKatie Marron
Revised report attached to case.
Routing Off Site - STRUCTURAL5/11/2017 5/12/2017 PASS
DetailsCarl Westfall
Chris Holladay (AHJ)
1st review completed  5/11/2017 DONE
Plan resubmittals requested  5/11/2017 DONE
Plan resubmittals received  5/11/2017 DONE
Routing - PLAN CHECK4/5/2017 5/11/2017 FAIL
DetailsCarl Westfall
Revised drawings required
Routing Off Site - STRUCTURAL4/5/2017 4/14/2017 FAIL
DetailsCarl Westfall
Chris Holladay (AHJ)
Routing PW Environmental4/5/2017 4/14/2017 PASS
DetailsRick Christenson
Routing - MECHANICAL4/5/2017 4/10/2017 PASS
DetailsChad Schwendiman
Routing - FIRE4/5/20174/5/20174/6/2017 FAIL
DetailsKatie Marron
Report attached to case and emailed to architect.
Routing - PLUMBING4/5/2017 4/5/2017 PASS
DetailsDaryl Spivey
Per plan and ISPC.
Routing - Addressing4/5/2017 4/5/2017 PASS
DetailsLaura Hunter
Added suite number 110
Routing - PUBLIC WORKS4/5/2017 4/5/2017 PASS
DetailsMorgan Webb
Routing - Erosion and Sediment4/5/2017 4/5/2017 PASS
DetailsAndy J. Long
See ESC16-00843 for coverage on Beechcraft Building. No new permit required
Intake Approval  4/5/2017 PASS
DetailsAdele J Schaffeld-Griffin
JAR completed pre screen and fees paid, Julie informed applicant this 1st time build out is a Major TI
Routing - Design Review4/5/2017 4/5/2017 PASS
DetailsAndrea Tuning
Intake Approval  4/4/2017 FAIL
DetailsJulie Romig
Provide U-factor for new door
Intake Approval  4/3/2017 FAIL
DetailsJulie Romig
Major Tenant Improvement, not a Minor. Submit Form 520 Checklist and all applicable documents including but not limited to the following items:
1. Site specific fire flow at hydrants letter
2. Structural calcs, foundation plans, wall framing/bracing - indicated on checklist but not attached.
3. Building envelope compliance for new door (U-factor & SHGC)
Application received  3/30/2017 DONE
Application submitted via PDS Online on Mar 30 2017 10:29AM