Permit Information
Permit NumberBLD17-01128
StatusFinaled
Name DEBELLOY CONSTRUCTION
Site Address 6438 S SUPPLY WAY
Project NameSealmaster TI
Customer Number 
ePlanReviewYes
Description
(SEALMASTER) **(05/31/17 PLAN MODIFICATION TO ADD OVERHEAD DOOR, NEW DRINKING FOUNTAIN LOCATION. JAR) **Permit is to remodel an existing 4,920 sq. ft. office/warehouse space to create retail space within the existing office for new tenant. This permit is approved contingent upon adhering to the approved plans on file. Work to include: demo existing nonbearing interior walls; construction of new ADA compliant service counter; addition of ADA compliant drinking fountain. Interior finishes must be in compliance with Ch. 8 of the 2012 IBC. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JAR**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 3/5/20184/6/2018 DONE
This permit finaled on the web by kevin debelloy
Third Notice 1/17/20182/12/2018 DONE
DetailsChristina Prado
Third Notice 12/17/20171/12/2018 DONE
Mailed 1-12-18
Third Notice 11/19/201712/12/2017 DONE
Mailed 12-13-17
Second Notice 10/22/201711/14/2017 DONE
Mailed 11-15-17
First Notice 9/25/201710/12/2017 DONE
Mailed 10-13-17
BLD-Final9/14/20179/14/20179/15/2017PPASS
DetailsJim Storey
Josh Phone #: ###-#### final ok no card on site
Print Occupancy Form  9/15/2017 DONE
Permanent Occupancy  9/15/2017 DONE
BLD-Final7/20/20177/20/20177/20/2017PFAIL
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by kevin debelloy need racking permit/ door hardware 2 nd floor/ back handrail if on plan set
FIRE-Final Inspection7/17/20177/17/20177/17/2017PPASS
DetailsJim Page
Fire sprinkler inspection complete, final life fire safety inspection passed/complete
FIRE-Final Inspection6/19/20176/19/20176/19/2017AFAIL
DetailsJim Page
Modifications need to be made to the fire sprinkler system to accomodate newly added equipment and roll up overhead door along the north wall. Storage racks exceed 8 feet in height, a racking permit is required for storage that exceeds 8 feet or the storage and racking needs to be lowered below 8 feet to the top of storage.
CHANGE STATUS TO (ISS)  6/16/2017 DONE
(F) Reprint permit  6/16/2017 DONE
Plan assigned to (JAR)5/11/20175/11/20175/31/2017 DONE
DetailsJulie Romig
Plan Mod - Resubmit rec'd on 05/24 - Sealmaster TI ePlan
Permit Ready to Issue  5/31/2017 DONE
DO NOT REISSUE; need revised value from GC
Routing - PLAN CHECK5/26/2017 5/26/2017 PASS
DetailsJulie Romig
Plan Modification for new overhead door and relocated drinking fountain.
Routing Off Site - STRUCTURAL5/24/2017 5/25/2017 PASS
DetailsJulie Romig
Plan Modification approved per ePlanReview
Routing - PLAN CHECK5/24/2017 5/25/2017 FAIL
DetailsJulie Romig
Applicant had additional information to include in plan modification. Failed in ePlanReview so applicant could upload new sheet.
Routing Off Site - STRUCTURAL5/11/2017 5/23/2017 FAIL
DetailsJulie Romig
Plan Mod - Corrections required in ePlanReview
Routing - Design Review5/11/2017 5/17/2017 PASS
DetailsSarah Schafer
Approved by Sarah Schafer per ePlanReview.
Routing - Erosion and Sediment5/11/2017 5/15/2017 PASS
DetailsAndy J. Long
No ESC permit needed
Routing - PLAN CHECK5/11/2017 5/11/2017 FAIL
DetailsJulie Romig
Plan Mod - Need overhead door R-value for IECC compliance.
Routing - PLANNING5/11/2017 5/11/2017 PASS
DetailsCody Riddle
Plan Modification Accepted  5/11/2017 DONE
plan mod accepted in e plan
BLD-Framing/Rough-in5/8/20175/9/20175/9/2017APASS
DetailsJim Storey
please call Shay at ###-#### 30 minutes before arrival to gain access if you could . Phone #: ###-#### Inspection requested via web by kevin debelloy
Route to Impact Fee Review5/3/20175/6/20175/4/2017 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Issue PAID IN FULL permit  5/4/2017 DONE
DetailsChristina Prado
Print Occupancy Form  5/4/2017 DONE
DetailsChristina Prado
Plan assigned to (JAR)4/27/20174/27/20175/3/2017 DONE
DetailsJulie Romig
1st Review Complete. DUE 05/10 - L2 Sealmaster TI
Routing - PLAN CHECK4/27/2017 5/3/2017 FAIL
DetailsJulie Romig
1st review completed  5/3/2017 FAIL
DetailsJulie Romig
Routing - PLAN CHECK5/3/2017 5/3/2017 PASS
DetailsJulie Romig
PLANS/APPL TAKEN TO FRONT DESK  5/3/2017 DONE
Permit Ready to Issue  5/3/2017 DONE
Need GC Form, Revised Cert of Value and **waiting for impact review to be completed as of 5-3-17**
Routing - FIRE5/2/20175/2/20175/2/2017 PASS
DetailsScott Arellano
Modifications to the sprinkler system MAY be required. PDS Fire Inspector to verify.
Routing - Addressing4/27/2017 4/28/2017 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS4/27/2017 4/28/2017 PASS
DetailsMorgan Webb
Intake Approval  4/27/2017 PASS
DetailsJavier Guzman
Intake Approval  4/25/2017 FAIL
DetailsAdele J Schaffeld-Griffin
Please see submittal standards for required stamping areas.

http://pds.cityofboise.org/media/105041/electronicstandards.pdf
Application received  4/20/2017 DONE
Application submitted via PDS Online on Apr 20 2017 4:55PM