BLD-Final | 8/10/2017 | 8/10/2017 | 8/10/2017 | P | PASS |
Mike Jordan
|
|
|
Please preform after electrical final inspection. Phone #: ###-#### Inspection requested via web by Tom Wells
|
DOC - Permit Finaled | 8/10/2017 | 8/10/2017 | 8/10/2017 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Energy code compliance | 7/6/2017 | 7/6/2017 | 7/6/2017 | A | PASS |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez
|
BLD-Framing/Rough-in | 6/30/2017 | 6/30/2017 | 6/30/2017 | A | PASS |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez
|
BLD-Footing | 6/30/2017 | 6/30/2017 | 6/30/2017 | A | PASS |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Recieved and reviewed calcs from designer for in place footing showing that they are ok as is.
|
BLD-Framing/Rough-in | 6/27/2017 | 6/27/2017 | 6/27/2017 | P | NR |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Spoke with Brian with Hayden Homes, needs to resolve footing issue prior to proceeding further.
|
BLD-Wall Bracing | 6/19/2017 | 6/19/2017 | 6/19/2017 | P | DONE |
Mike Jordan
|
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez
|
BLD-Wall Bracing | 6/15/2017 | 6/16/2017 | 6/16/2017 | P | PASS |
Brandon Shaw
|
|
|
Zane Phone #: ###-####
|
BLD-Footing | 6/2/2017 | 6/2/2017 | 6/2/2017 | A | FAIL |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron. Footing placed. will need to remove portion were reinforcement at elongated column pad footings are and install correct rebar.
|
BLD-Footing | 6/1/2017 | 6/1/2017 | 6/1/2017 | P | FAIL |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron. Reinforcement not installed per approved plans at column pad footings.
|
Issue PAID IN FULL permit | | | 5/30/2017 | | DONE |
|
|
|
|
OVERRIDE | | | 5/25/2017 | | |
|
|
|
|
Route to Impact Fee Review | 5/25/2017 | 5/28/2017 | 5/25/2017 | | PASS |
Marissa Taylor
|
|
|
Review requested for Commercial Permit
|
Plan assigned to (JG) | 5/16/2017 | 5/16/2017 | 5/25/2017 | | PASS |
Javier Guzman
|
|
|
5/25 L1 SFD paper
|
1st review completed | | | 5/25/2017 | | DONE |
Javier Guzman
|
|
|
|
Case Summary (BLD) | | | 5/25/2017 | | DONE |
Javier Guzman
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/25/2017 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 5/25/2017 | | DONE |
|
|
|
met
|
Inspection Record Card- Bld | | | 5/25/2017 | | DONE |
|
|
|
|
Telephone call | | | 5/25/2017 | | DONE |
Christina Prado
|
|
|
Called Brian to advise permit is ready and gave fees due
|
Routing - PLAN CHECK | 5/17/2017 | | 5/25/2017 | | PASS |
Javier Guzman
|
|
|
|
Routing - Addressing | 5/12/2017 | | 5/25/2017 | | PASS |
Laura Hunter
|
|
|
signed off in PW revew rreport by Laura Hunter
|
Routing - MECHANICAL | 5/15/2017 | | 5/17/2017 | | PASS |
Troy James
|
|
|
|
Plan assigned to (BJM) | 5/12/2017 | 5/12/2017 | 5/16/2017 | | DEFR |
Brian McGowan
|
|
|
|
Routing - PLANNING | 5/15/2017 | | 5/15/2017 | | PASS |
Sue Cummings
|
|
|
|
Routing - PUBLIC WORKS | 5/12/2017 | | 5/15/2017 | | PASS |
Morgan Webb
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 5/12/2017 | | DONE |
|
|
|
|
Intake Approval | | | 5/12/2017 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 5/12/2017 | | DONE |
|
|
|
|
Application received | | 5/11/2017 | | | |
|
|
|
|