Permit Information
Permit NumberBLD17-01479
StatusFinaled
Name CANNING CONSTRUCTION INC
Site Address 8011 W USTICK RD
Project NameIdaho High School Activities
Customer NumberBLD17-01956
ePlanReviewYes
Description
(IDAHO HIGH SCHOOL ACTIVITIES – ENCLOSING OPEN AREA – WEST END OF BUILDING) (DRH16-00376) (12-19-17 PLAN MODIFICATION TO INSTALL WIDE FLANGE STEEL BEAMS ABOVE NEW OPENINGS IN AN INTERIOR MASONRY SHEAR WALL. TENSION PLATES WILL BE INSTALLED TO CONNECT THE BEAMS FROM END TO END SO THAT THE BEAMS AND STRAPS WILL ALL FUNCTION AS A DRAG STRUT. THIS REPLACES THE FORMERLY PROPOSED MASONRY LINTELS WITH STEEL ANGLES ON EACH SIDE ABOVE NEW OPENINGS. SPECIAL INSPECTION IS REQUIRED FOR WELDING. AT ANOTHER LOCATION, AN EXISTING COLUMN WILL BE CONCEALED BY AN EXTERIOR FURRED OUT WALL. IN ADDITION, THE HEIGHT OF THE TRASH ENCLOSURE WALLS WILL BE REDUCED FROM 7’- 4” TO 6’- 0”.) Drawings for permits BLD17-01479 and BLD17-01956 are filed under BLD17-01479 in ePlanReview. This building does not have a fire sprinkler system. To enclose a 998 square foot covered area that is part of a 6,424 square foot existing building. The roof structure above will remain. Work is to include concrete footings, concrete foundation stem walls, concrete slabs on grade, masonry exterior walls with interior continuous insulation, wood frame exterior walls with R-19 insulation, exterior windows, exterior door, interior doors, interior windows, millwork, and finishes. Special Inspection is required for concrete, masonry, and for post installed anchors in hardened concrete. This permit is intended to establish a new Certificate of Occupancy for the entire building. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Print Statement  7/16/2018 DONE
First Notice 6/30/20187/11/2018 DONE
mailed 7-12-18
BLD-Final6/19/20186/20/20186/20/2018APASS
DetailsJim Sly
Greg Phone #: ###-####
OK for Perm Occ.
Permanent Occupancy  6/20/2018 DONE
Zoning Approval6/19/20186/19/20186/19/2018 DONE
DetailsAndrea Tuning
FIRE-Final Inspection5/2/20185/2/20185/2/2018PPASS
DetailsTroy Cobbley
Life safety passed

Greg Phone #: ###-####
BLD-Final3/2/20183/2/20183/2/2018PPART
DetailsJim Sly
Greg Phone #: ###-####
Phase 1 ......OK.
FIRE-Final Inspection3/2/20183/2/20183/2/2018PPART
DetailsTroy Cobbley
Phase 1 area life safety passed.

Greg Phone #: ###-####
FIRE-Conference2/23/20182/23/20182/23/2018PDONE
DetailsTroy Cobbley
We discussed life safety requirements. I noted that the wrong remote annunciator had been installed for the duct smoke detector and that the exit discharge light was missing at the west exit door.

Greg Phone #: ###-####
BLD-Other2/13/20182/13/20182/13/2018PPASS
DetailsJim Sly
Tbar grid - Greg Phone #: ###-####
BLD-Energy code compliance1/22/20181/22/20181/22/2018PPASS
DetailsJim Sly
Greg Phone #: ###-####
BLD-Framing/Rough-in1/17/20181/18/20181/18/2018APASS
DetailsJim Sly
Greg Phone #: ###-####
BLD-Framing/Rough-in1/8/20181/8/20181/8/2018PPASS
DetailsJim Sly
Jeff-Ceiling Rough Framing Phone #: ###-#### Inspection requested via web by Jeff Canning
BLD-Other12/29/20171/2/20181/2/2018PDONE
DetailsJim Sly
Jeff-CMU inspection Phone #: ###-####
CMU Completed. OK pending all inspections, tests and approval by Geotek.
BLD-Other12/26/201712/27/201712/27/2017APASS
DetailsJim Sly
cmu inspection // Jeff Phone #: ###-####
CMU final lift OK pending Geotek special inspection, tests and approvals.
CHANGE STATUS TO (ISS)  12/21/2017 DONE
OVERRIDE  12/20/2017  
Permit Ready to Issue  12/20/2017 DONE
DO NOT REISSUE, plan mod fees due
Plan assigned to (CJW)11/30/201711/30/201712/19/2017 PASS
DetailsCarl Westfall
x (1st done) Plan Modification "high school activities"
Routing Off Site - STRUCTURAL12/19/2017 12/19/2017 PASS
DetailsCarl Westfall
On hold until stamped structural calculations were received. Ashley Thompson (KPFF))
Routing PW Solid Waste12/14/2017 12/19/2017 PASS
DetailsEvan Carpenter
The solid waste enclosure is approved for shorter walls.

Note the comment on the site plan (AS1-0) stating the solid waste enclosure must have at least 12 feet of unobstructed clearance between gate posts. The enclosure will need to be in compliance with the below design standards before a container can be delivered.
Plan Reviewer's activity  12/19/2017 PASS
Plan modification approved
Routing - Design Review12/14/2017 12/14/2017 PASS
DetailsAndrea Tuning
Approved with redlines to provide a 5-foot clear sidewalk outside of the bicycle parking area and label one compact parking space.
Routing - PUBLIC WORKS12/14/2017 12/14/2017 PASS
DetailsMorgan Webb
Trash enclosure walls being shortened
Routing - PLAN CHECK12/13/2017 12/14/2017 PASS
DetailsCarl Westfall
(12-14-17) Need structural calculations to validate the design.

(12-19-17) Structural calculations received and uploaded. Workflow routed to consultant structural engineer. Passed pending the structural review.
Plan Modification Accepted  12/13/2017 DONE
Workflow in ePlanReview received
Plan Modification Accepted  11/30/2017 DONE
DetailsChristina Prado
Plan Mod to reduce trash enclosure height and update misc. cmu walls
BLD-Footing11/20/201711/20/201711/20/2017PPASS
DetailsJim Sly
Jeff Phone #: ###-####
OK pending Geotek special inspection, tests and approvals.
OVERRIDE  10/11/2017  
Print Occupancy Form  10/11/2017 DONE
CHANGE STATUS TO (ISS)  10/11/2017 DONE
Issue PAID IN FULL permit  10/11/2017 DONE
Inspection Record Card- Bld  10/11/2017 DONE
Print Occupancy Form  10/11/2017 DONE
Permit Ready to Issue  10/11/2017 DONE
WAITING FOR ACHD DO NOT REISSUE. SENT AN EMAIL TO JEFF WITH CANNING CONSTRUCTION
OVERRIDE  10/9/2017  
Plan assigned to (CJW)6/20/2017 10/9/2017 PASS
DetailsCarl Westfall
(2nd done) (July 24 - 25 days) (44 sheets) Idaho High School Activities - remodel
Routing Off Site - STRUCTURAL10/6/2017 10/9/2017 PASS
DetailsCarl Westfall
Ashley Thompson (KPFF)
PLANS/APPL TAKEN TO FRONT DESK  10/9/2017 DONE
Permit Ready to Issue  10/9/2017 DONE
MET
Need
RP - MET
GC Form - MET
Revised Cert of Value - MET
ACHD
**DO NOT ISSUE WITHOUT BLD17-01956**
Plan resubmittals received  10/6/2017 DONE
Routing - PLAN CHECK10/6/2017 10/6/2017 PASS
DetailsCarl Westfall
Pending approval by structural - routed drawings
Plan resubmittals requested  10/4/2017 DONE
Routing Off Site - STRUCTURAL9/27/2017 10/4/2017 FAIL
DetailsCarl Westfall
Ashley Thompson (KPFF)
Routing - FIRE9/27/2017 10/2/2017 PASS
DetailsKatie Marron
Comments attached to case
Routing - Design Review9/29/2017 9/29/2017 PASS
DetailsAndrea Tuning
Approved with redlines to provide a 5-foot clear sidewalk outside of the bicycle parking area and label one compact parking space.
Routing - MECHANICAL9/27/2017 9/28/2017 PASS
DetailsTroy James
Routing - PLAN CHECK9/26/2017 9/27/2017 PASS
DetailsCarl Westfall
Pending approval by structural
Routing PW Sewer Rating9/27/2017 9/27/2017 PASS
DetailsMorgan Webb
Drinking fountains added. WEST BOISE SEWER DISTRICT.
Routing PW Drainage9/27/2017 9/27/2017 PASS
DetailsBrian Murphy
less than 1000ft2
Routing - Design Review9/27/2017 9/27/2017 FAIL
DetailsAndrea Tuning
Sidewalk adjacent to the bicycle parking shall be 5-feet in width and the parking space adjacent to the new termial planter should be labeled as compact.
Plan resubmittals received  9/26/2017 DONE
Route to Impact Fee Review8/10/20178/13/20178/11/2017 PASS
DetailsMarissa Taylor
Review requested for Commercial Permit
1st review completed  8/10/2017 DONE
Plan resubmittals requested  8/10/2017 DONE
Emailed plan review report to Architect. Will route workflow in ePlanReview back to the Architect when the garage review is completed
Routing - PLAN CHECK6/20/2017 8/10/2017 FAIL
DetailsCarl Westfall
Revised drawings required
Routing PW Drainage6/20/2017 6/29/2017 PASS
DetailsBrian Murphy
Engineer letter less than 1000
Routing Off Site - STRUCTURAL6/20/2017 6/27/2017 FAIL
DetailsCarl Westfall
Ashley Thompson (KPFF)
Routing - PLANNING Land Div6/20/2017 6/21/2017 PASS
DetailsTodd Tucker
Routing - Erosion and Sediment6/20/2017 6/21/2017 PASS
DetailsMelissa Jannusch
General ESC permit issued.
Routing - MECHANICAL6/20/2017 6/21/2017 FAIL
DetailsTroy James
Routing - FIRE6/20/20176/20/20176/20/2017 FAIL
DetailsKatie Marron
Report attached to case and emailed to architect.
Intake Approval  6/20/2017 PASS
DetailsAdele J Schaffeld-Griffin
Julie approved pre screen and notified applicant this is a 502 application not a 520
Plan Reviewer's activity  6/20/2017 DONE
DetailsAdele J Schaffeld-Griffin
email sent to applicant Jeff, Please make sure that you reach out to ACHD for review on this change of use/occupancy. If additional fees are due they will need to be paid or paid when the permit is issued. If no fees are do please submit the documentation from ACDH as such.

Thank you

Routing - Design Review6/20/2017 6/20/2017 FAIL
DetailsAndrea Tuning
a. Install four (4) bicycle parking spaces on an approved surfacing that is convenient and visible to individuals using alternative modes of transportation.
b. Install a vertical curb line at the terminus of the pavement to prohibit individuals from driving or parking in the undeveloped area.
c. Provide a total of eight (8) Class I street trees along Ustick Road.
d. Widen the terminal planter at the west end of the parking lot to be a minimum of 8-feet in width (measured inside of curb to inside of curb) and include a Class II tree with shrubs or groundcover.
Routing - Addressing6/20/2017 6/20/2017 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS6/20/2017 6/20/2017 PASS
DetailsRachael Beierle
Intake Approval  6/14/2017 FAIL
DetailsJulie Romig
Neeed 2 applications uploaded:

- (1) application for the Addition and Remodel with revised square footage, occupant load, and valuation specific to the Addition/Remodel.
- (1) application for the new Garage Building with square footage, occupant load, and valuation specific to the Garage.
Intake Approval  6/7/2017 FAIL
DetailsJulie Romig
Since the project has 2 different buildings, a second building permit will be issued for the garage building. There will only be one ePlanReview case, but you need to upload (2) PDFs of the 502 Building Applications:
- (1) for the Addition and Remodel with revised square footage, occupant load, and valuation specific to the Addition.
- (1) for the new Garage Building with square footage, occupant load, and valuation specific to the Garage.

Also upload the following:
- Provide calcs showing existing roof structure can support additional load of new RTU.
- Mechanical COMcheck uses 90.1 (2013) Standard, Building and Electrical COMchecks use 2012 IECC. All three must use the same energy code path. Submit Mechanical COMcheck for 2012 IECC or submit new Building and Electrical COMcheck using 90.1 (2013) Standard.
- Missing stamp/signature on the following sheets: G1.1, AS1.0, A1.1, A4.2, A5.1, A6.1, A8.1, A8.2, A8.3, A9.1
Intake Approval  5/16/2017 FAIL
Applicant submitted drawings/docs for a different project. Deleted and sent application back after discussing with Jeff Likes.
Plan Reviewer's activity  5/16/2017  
Route as 502 Addition. Called Jeff Likes and let him know that the project will be routed as a 502 and not a 520.
Application received  5/15/2017 DONE
Application submitted via PDS Online on May 15 2017 8:57AM