Permit Information
Permit NumberBLD17-01528
StatusFinaled
Name KWJ CONSTRUCTION INC
Site Address 4800 W OVERLAND RD
Project NameBurger King TI
Customer Number 
ePlanReviewNo
Description
(BURGER KING) **This building is not Fire Sprinklered. Permit for interior and exterior improvements to an existing Burger King. Work to include: removal of existing mansard roof sections and construction of new parapets; removal and replacement of existing storefronts and doors; demo of exterior walls added under BLD96-01157 to expand restroom and infilling exterior wall in original location on existing foundation; new exterior finishes; demo interior nonbearing walls; new interior non-bearing walls; remodel ADA compliant restrooms; new lighting fixtures and ceiling grid; new plumbing, mechanical, and electrical; and new interior finishes in compliance with Ch. 8 of the 2012 IBC. All work to be done per the approved plans, DRH17-00180, and applicable codes and ordinances. **JAR**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 8/20/20179/11/2017 DONE
This permit finaled on the web by jacob johnson
First Notice7/27/20177/27/20178/10/2017 DONE
DetailsJim Sly
Mailed 8-11-17
BLD-Final7/26/20177/27/20177/27/2017PPASS
DetailsJim Sly
Kipp-would like as early as possible Phone #: ###-####
OK for Perm Occ.
DOC - Permit Finaled7/27/20177/27/20177/27/2017PPASS
DetailsJim Sly
FIRE-Final Inspection7/25/20177/26/20177/26/2017PPASS
DetailsTroy Cobbley
Life safety passed
Zoning Approval7/26/20177/26/20177/26/2017 PASS
DetailsKatelyn Menuge
Design Review-DRH17-00180
BLD-Final7/24/20177/25/20177/25/2017PNR
DetailsJim Sly
Ben Phone #: ###-####
Went over Required inspection to obtain Cert of Occ.
FIRE-Final Inspection7/24/20177/25/20177/25/2017AFAIL
DetailsTroy Cobbley
Provide re-certification of both hood suppression systems, repair/install all exit signs/emergency lights/exit discharge lights and provide testing, provide tagged fire extinguishers per plans and discussion, provide occupant load sign, provide data sheet verifying the restroom doors meet ADA, blank keyed dead bolt to Play Land.
Inspection Record Card- Bld  7/25/2017 DONE
BLD-Ceiling Grid Inspection7/19/20177/20/20177/20/2017APASS
DetailsJim Sly
Ben Phone #: ###-####
BLD-Framing/Rough-in7/13/20177/13/20177/13/2017PPASS
DetailsJim Sly
Ben Phone #: ###-####
BLD-Framing/Rough-in7/11/20177/12/20177/12/2017APASS
DetailsJim Sly
Ben Phone #: ###-####
BLD-Framing/Rough-in7/10/20177/11/20177/11/2017APART
DetailsJim Sly
Ben Phone #: ###-####
Metal framed drop soffits.....OK.
BLD-Framing/Rough-in7/7/20177/10/20177/10/2017APART
DetailsJim Sly
Ben Phone #: ###-####
All framing OK except Rest Rooms.
OVERRIDE  7/5/2017  
Telephone call  7/5/2017 DONE
Spoke with Ke informing her that this permit is ready and that we need a 306, 302 and who the RP will be from the GC
Inspection Record Card- Bld  7/5/2017 DONE
Issue PAID IN FULL permit  7/5/2017 DONE
PLANS/APPL TAKEN TO FRONT DESK  7/5/2017 DONE
showing in REV still since a case summary was done after Julie had signed off on Plans taken to front desk
Permit Ready to Issue  7/5/2017 DONE
Need RP, GC Form and Revised Cert of Value
Route to Impact Fee Review6/29/20177/5/20177/4/2017 PASS
DetailsEric Bilimoria
Plan assigned to (JAR)5/23/20175/23/20176/30/2017 DONE
DetailsJulie Romig
1st Review Comp - Resubmitted 06/29 - PAPER - Burger King TI.
Case Summary (BLD)  6/30/2017  
PLANS/APPL TAKEN TO FRONT DESK  6/30/2017 DONE
Routing - PLAN CHECK6/29/2017 6/30/2017 PASS
DetailsJulie Romig
1st review completed  6/28/2017 FAIL
DetailsJulie Romig
Emailed plan review report to applicant.
Routing - PLAN CHECK6/5/2017 6/28/2017 FAIL
DetailsJulie Romig
Routing - FIRE6/23/2017 6/23/2017 PASS
DetailsScott Arellano
Basic Life Safety. Minor work on kitchen finishes; no work/changes to equipment. Verify existing kitchen hood system is current with inspection tag.
Plan Reviewer's activity  6/23/2017  
Spoke with applicant regarding time frame. Call when review is complete at ###-####.
Routing - Design Review6/7/2017 6/7/2017 PASS
DetailsKatelyn Menuge
Idaho Power Approval Received. Design Review per DRH17-00180
Routing - PLUMBING  6/5/2017 PASS
DetailsBill VanDegrift
restroom remodel. no work in the kitchen.
Routing - Erosion and Sediment  5/31/2017 PASS
DetailsMelissa Jannusch
Plan waiver approved. Need to designate RP.
Routing - Design Review5/25/2017 5/26/2017 FAIL
DetailsKatelyn Menuge
Drawings Okay-Need approval letter from Idaho Power
Routing PW Environmental5/23/2017 5/25/2017 PASS
DetailsRick Christenson
Routing - PUBLIC WORKS  5/25/2017 PASS
DetailsRachael Beierle
Telephone call  5/23/2017 DONE
called Bfrian to see if he was sending the struc calcs-he said he sent them with them with the plans but they weren't in there so he is emailing them to me and I'll take them to Julie
Intake Approval  5/23/2017 PASS
Received stamped finish drawings and structural calcs.
Routing - Addressing5/23/2017 5/23/2017 PASS
DetailsLaura Hunter
Routing PW Sewer Rating5/23/2017 5/23/2017 PASS
DetailsMorgan Webb
Plans ACCEPTED BY PLAN TECH  5/17/2017 DONE
Intake Approval  5/17/2017 FAIL
Need stamped finish drawings and structural calcs. Julie held drawing set, waiting for architect to mail rest of drawings and calcs and will incorporate into sets already received.
Recd Pcfee & Taken To Pln CK  5/17/2017 DONE
Application received 5/17/2017