Permit Information
Permit NumberBLD17-01732
StatusFinaled
Name DOUG LASHER CONSTRUCTION
Site Address 3282 E HEARTLEAF DR
Project Name 
Customer Number 
ePlanReviewNo
Description
BOND BND18-00004 HILLSIDE, WUI ZONE "A", CLASS "A" ROOF REQUIRED. Permit for the construction of a new 3403 sq. ft., two story (first story 2191 sq. ft., second story 1212 sq. ft.) single family dwelling with 4 bedrooms, 3.5 bathrooms, approximately 212 sq. ft. of covered patio/porch and a 786 sq. ft. attached garage per the approved plans and any notations. R-1C zoning and setbacks per planning. **BJM**A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at 608-7168

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at 608-7168.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/19/20181/22/20181/22/2018PPASS
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by bryan murdoch
DOC - Permit Finaled1/22/20181/22/20181/22/2018PPASS
DetailsJim Storey
BLD-Final1/18/20181/19/20181/19/2018PCANC
DetailsJim Storey
Call 30 minutes in advance please Phone #: ###-#### >> Inspection requested via web by bryan murdoch Inspection cancelled from web by: bryan murdoch
PubWorks Occupancy Approval1/18/20181/18/20181/18/2018 DONE
DetailsMelissa Jannusch
BOND
BLD-Energy code compliance10/27/201710/27/201710/27/2017PPASS
DetailsJim Storey
Thanks Phone #: ###-#### Inspection requested via web by bryan murdoch
Plan Modification Accepted  10/26/2017 DONE
new manual j report
Routing - MECHANICAL10/26/2017 10/26/2017 PASS
DetailsTroy James
resubmitted manual j report
BLD-Framing/Rough-in10/24/201710/24/201710/24/2017PPART
DetailsJim Storey
Thanks Phone #: ###-#### Inspection requested via web by bryan murdoch need header at pocket door west bath. ok to insulate
BLD-Wall Bracing10/2/201710/2/201710/2/2017PPASS
DetailsJim Storey
Thanks Phone #: ###-#### Inspection requested via web by bryan murdoch
BLD-Foundation7/17/20177/18/20177/18/2017APASS
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by bryan murdoch
BLD-Footing7/12/20177/13/20177/13/2017PPASS
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by bryan murdoch
Routing - PUBLIC WORKS GRADING7/11/2017 7/11/2017 PASS
DetailsJim Wyllie
Received letter from Site Consulting approving footing subgrade. Okay to schedule a footing inspection.

Jim Wyllie / ###-####
OVERRIDE  7/7/2017  
Plan assigned to (BJM) 6/2/20177/7/2017 DONE
DetailsBrian McGowan
1st review complete- FAIL- 6/22 sfd Level 2 paper
Inspection Record Card- Bld  7/7/2017 DONE
Issue PAID IN FULL permit  7/7/2017 DONE
Routing PW Grading-Hillside6/29/2017 7/7/2017 PASS
DetailsJason C. Taylor
Approved resubmittals. JCT
Routing - PLAN CHECK7/7/2017 7/7/2017 PASS
DetailsBrian McGowan
Case Summary (BLD)  7/7/2017 DONE
DetailsBrian McGowan
PLANS/APPL TAKEN TO FRONT DESK  7/7/2017 DONE
DetailsBrian McGowan
Permit Ready to Issue  7/7/2017 DONE
All requirements are met
Plan resubmittals received  6/29/2017 DONE
received three copies of plan sheet C1 and two copies of plan sheets s101, s102, s105 and engineering calcs; taken to Brian McGowan
1st review completed  6/27/2017 FAIL
DetailsBrian McGowan
Need engineering for knee brace support, foundation plan revisions and possibly grading plan revisions.
Routing - PLAN CHECK6/16/2017 6/27/2017 FAIL
DetailsBrian McGowan
Need engineering for knee brace support, foundation plan revisions and possibly grading plan revisions.
Routing - PLANNING6/12/2017 6/27/2017 PASS
DetailsSue Cummings
Routing - FIRE6/15/20176/2/20176/16/2017 PASS
DetailsKatie Marron
Plans were reviewed for FD Access, hydrant availability and defensible space.
Routing - Erosion and Sediment6/13/2017 6/15/2017 PASS
DetailsAndy J. Long
ESC site plan and narrative approved. Valid PD and RP. ESC site preparation inspection is required.
Routing - MECHANICAL  6/13/2017 PASS
DetailsTroy James
Routing PW Grading-Hillside6/12/2017 6/12/2017 PASS
DetailsJason C. Taylor
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at ###-####

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at ###-####.
Routing - PUBLIC WORKS6/12/2017 6/12/2017 PASS
DetailsRachael Beierle
Plan resubmittals received  6/6/2017 DONE
resubmittal received 2 small site plans and 2 of sheet C1-called Brian M to see if i should take them to JCT-no answer so took to Brian McGowan
Routing PW Grading-Hillside6/2/2017 6/6/2017 FAIL
DetailsJason C. Taylor
Need updated grading plans dropped off for review. Stamp date of 5-31-17 is needed. JCT
Routing - PUBLIC WORKS6/6/2017 6/6/2017 FAIL
DetailsRachael Beierle
Route to Impact Fee Review6/2/20176/5/20176/5/2017 PASS
DetailsMarissa Taylor
Initial residential review of new SFD permits requested for now.
Routing - Addressing6/2/2017 6/2/2017 PASS
DetailsLaura Hunter
Plans ACCEPTED BY PLAN TECH  6/2/2017 DONE
DetailsChristina Prado
Intake Approval  6/2/2017 PASS
DetailsChristina Prado
Recd Pcfee & Taken To Pln CK  6/2/2017 DONE
DetailsChristina Prado
Routing PW Sewer Rating6/2/2017 6/2/2017 PASS
DetailsMorgan Webb
Application received 6/2/2017