Third Notice | | 11/19/2017 | 11/21/2017 | | DONE |
|
|
|
This permit finaled on the web by Mike McHargue
|
Second Notice | | 10/22/2017 | 11/14/2017 | | DONE |
|
|
|
Mailed 11-15-17
|
First Notice | | 10/6/2017 | 10/12/2017 | | DONE |
|
|
|
Mailed 10-13-17
|
BLD-Final | 9/26/2017 | 9/26/2017 | 9/26/2017 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Mike McHargue. Ok for perm occ.
|
Permanent Occupancy | | | 9/26/2017 | | DONE |
Christina Prado
|
|
|
|
FIRE-Final Inspection | 9/22/2017 | 9/25/2017 | 9/25/2017 | A | PASS |
Troy Cobbley
|
|
|
Life safety passed
|
FIRE-Final Inspection | 9/22/2017 | 9/22/2017 | 9/22/2017 | A | CANC |
Jim Page
|
|
|
Called point of contact provided two times, Mike McHargue Phone #: ###-####, message was left on voicemail. Proceeded to tenant space for inspection, tenant space was locked with no access, life fire safety inspection will need to be rescheduled, this request is cancelled.
|
BLD-Ceiling Grid Inspection | 9/15/2017 | 9/15/2017 | 9/15/2017 | A | PASS |
Jim Storey
|
|
|
Phone #: ###-#### Inspection requested via web by Mike McHargue
|
BLD-Wall cover | 8/7/2017 | 8/8/2017 | 8/8/2017 | A | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Mike McHargue
|
BLD-Energy code compliance | 8/7/2017 | 8/8/2017 | 8/8/2017 | A | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Mike McHargue
|
BLD-Framing/Rough-in | 8/8/2017 | 8/8/2017 | 8/8/2017 | A | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Mike McHargue
|
BLD-Wall cover | 8/7/2017 | 8/7/2017 | 8/7/2017 | P | NR |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Mike McHargue
|
BLD-Energy code compliance | 8/7/2017 | 8/7/2017 | 8/7/2017 | P | NR |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Mike McHargue
|
BLD-Framing/Rough-in | 8/3/2017 | 8/4/2017 | 8/4/2017 | P | FAIL |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Mike McHargue. Complete airseal on allexterior walls and foam all top plate penetrations. Patch all holes in draft stop. Fireblock all fur downs. ok toinsualte. orrection notice posted.
|
BLD-Framing/Rough-in | 8/3/2017 | 8/3/2017 | 8/3/2017 | P | CANC |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by Mike McHargue Inspection cancelled from web by: Mike McHargue
|
Route to Impact Fee Review | 7/5/2017 | 7/8/2017 | 7/7/2017 | | PASS |
Eric Bilimoria
|
|
|
Review requested for Commercial Permit
|
Print Occupancy Form | | | 7/7/2017 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 7/7/2017 | | DONE |
|
|
|
|
Plan assigned to (JG) | 6/13/2017 | 6/13/2017 | 7/6/2017 | | PASS |
Javier Guzman
|
|
|
1st rev comp, 7/03 L3 Idaho Tax & Accounting TI ePlan
|
Routing - PLAN CHECK | 7/6/2017 | | 7/6/2017 | | PASS |
Javier Guzman
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/6/2017 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 7/6/2017 | | DONE |
|
|
|
Need GC Form and Revised Cert of Value
|
1st review completed | | | 7/5/2017 | | FAIL |
Javier Guzman
|
|
|
|
Routing - PLAN CHECK | 6/13/2017 | | 7/5/2017 | | FAIL |
Javier Guzman
|
|
|
|
Routing - Erosion and Sediment | 6/13/2017 | | 7/5/2017 | | PASS |
Melissa Jannusch
|
|
|
signed off in ePlan by Erosion Melissa Jannusch
|
Routing - MECHANICAL | 6/13/2017 | | 6/14/2017 | | PASS |
Troy James
|
|
|
|
Routing - FIRE | 6/13/2017 | 6/13/2017 | 6/13/2017 | | PASS |
Katie Marron
|
|
|
No comments required. Basic Life Safety.
|
Routing - Addressing | 6/13/2017 | | 6/13/2017 | | PASS |
Laura Hunter
|
|
|
|
Routing - PUBLIC WORKS | 6/13/2017 | | 6/13/2017 | | PASS |
Rachael Beierle
|
|
|
|
Intake Approval | | | 6/13/2017 | | PASS |
Adele J Schaffeld-Griffin
|
|
|
Pre screen approved by Julie
|
Intake Approval | | | 6/9/2017 | | FAIL |
Julie Romig
|
|
|
1. Rotate cover and architectural sheets.
2. Rename all drawing files with sheet number and brief description per City of Boise naming conventions.
|
Application received | | | 6/7/2017 | | DONE |
|
|
|
Application submitted via PDS Online on Jun 7 2017 1:45PM
|