Information based on query as of Saturday, June 29, 2024.
Permit Information
Permit NumberBLD17-01988
StatusFinaled
Name CH PRO LLC
Site Address 6255 N PIERCE PARK LN
Project Name6255 N PIERCE PARK LN. BOISE 8
Customer Number 
ePlanReviewYes
Description
*** Engineering provided for hold downs and anchor bolts 1-16-18 *** BJM *** FLOODPLAIN. Permit for the construction of a new 3084 sq. ft., two story (first story 2646 sq. ft., second story 438 sq. ft.) single family dwelling with 5 bedrooms, 3 bathrooms, approximately 335 sq. ft. of covered patio/porch and a 1058 sq. ft. attached garage per the approved plans. R-1C zoning and setbacks per planning. Prescriptive Energy Code is proposed. **BJM** NOTE:
Two Elevation Certificates will be required; one prior to receiving a framing inspection, and one based upon finished construction. These certificates will need to be reviewed and approved by Public Works staff prior to occupancy approval. Jason Taylor 208-608-7171
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/1/20186/4/20186/4/2018APASS
DetailsTony Young
Vedad Phone #: ###-####
DOC - Permit Finaled6/4/20186/4/20186/4/2018PPASS
DetailsTony Young
c of o issued
BLD-Final5/25/20185/29/20185/29/2018AFAIL
DetailsMike Jordan
Vedad---Please call 30 mins before Phone #: ###-####. Needs to provide guard at west side of house at retaining wall. Provide blower door test result and post.
PubWorks Occupancy Approval5/25/20185/25/20185/25/2018 DONE
DetailsJason C. Taylor
Elevation Cert Rec'd-Final  5/25/2018 DONE
BLD-Ceiling Grid Inspection4/16/20184/17/20184/17/2018APEND
DetailsTony Young
Call for access // Vedad Phone #: ###-####,, ceiling insulation,, just need to see the insulation self certification sticker at the final
BLD-Ceiling Grid Inspection4/16/20184/16/20184/16/2018PDEFR
DetailsJim Storey
Call for access // Vedad Phone #: ###-#### to tony am tue
Elevation Cert Rec'd-Midconst  4/16/2018 DONE
BLD-Wall cover1/26/20181/29/20181/29/2018APASS
DetailsTony Young
Vedad Phone #: ###-####
BLD-Wall cover1/25/20181/26/20181/26/2018ANR
DetailsTony Young
Vedad Phone #: ###-####,, need to replace missing insulation where it has blown out and need to build chases
BLD-Energy code compliance1/24/20181/25/20181/25/2018APART
DetailsTony Young
Vedad Phone #: ###-####,, replace blown out insulation,, fire block new chases when they are built
BLD-Framing/Rough-in1/19/20181/22/20181/22/2018APASS
DetailsTony Young
Call half hour before to meet /// Vedad Phone #: ###-####
OVERRIDE  1/19/2018  
Plan assigned to (BJM)11/8/201711/8/20171/19/2018 DONE
DetailsBrian McGowan
FAIL -plan mod
CHANGE STATUS TO (ISS)  1/19/2018 DONE
DetailsChristina Prado
Plan Mod approved, no fees due
Routing PW Flood Plain1/19/2018 1/19/2018 PASS
DetailsJason C. Taylor
JCT requested I sign off for him.
Permit Ready to Issue  1/19/2018 DONE
Plan Mod approved, no fees due
Routing - PLAN CHECK1/16/2018 1/16/2018 PASS
DetailsBrian McGowan
CHANGE STATUS TO (REV)  1/16/2018 DONE
changed to fee status by mistake
Plan Reviewer's activity  12/14/2017  
DetailsBrian McGowan
Talked to Vedad. I explained that he needs to show how he replaced the anchor bolts.
Routing - PLAN CHECK11/8/2017 11/13/2017 FAIL
DetailsBrian McGowan
Plan Mod to update engineering. Need more specific engineering. Not just holddown substitutes.
Plan Modification Accepted  11/8/2017 DONE
DetailsChristina Prado
Plan mod to update stem wall
BLD-Wall Bracing11/6/201711/7/201711/7/2017AFAIL
DetailsBrandon Shaw
Need revised Engineering- stem wall was wrong height, builder cut approx 12" off stem wall elevation. No hold downs in place at time of inspection
Elevation Cert Rec'd-Midconst  10/3/2017 DONE
Routing PW Flood Plain10/3/2017 10/3/2017 PASS
DetailsJason C. Taylor
Two Elevation Certificates will be required; one prior to receiving a framing inspection, and one based upon finished construction. These certificates will need to be reviewed and approved by Public Works staff prior to occupancy approval. Jason Taylor ###-####
BLD-Foundation9/19/20179/20/20179/20/2017APART
DetailsTony Young
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo ,, work in progress
BLD-Footing9/18/20179/19/20179/19/2017PPART
DetailsTony Young
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo ,, work in progress
Issue PAID IN FULL permit  9/15/2017 DONE
Place hold on job9/15/2017 9/15/2017 DONE
DetailsTiffany Carson-Herker
Need signed permit, see Tiffany
Inspection Record Card- Bld  9/15/2017 DONE
OVERRIDE  9/14/2017  
Plan assigned to (BJM)6/26/20176/26/20179/14/2017 DONE
DetailsBrian McGowan
1st review complete - FAIL - 7/7 sfd ePlan Level 1
Routing - PLAN CHECK9/14/2017 9/14/2017 PASS
DetailsBrian McGowan
PLANS/APPL TAKEN TO FRONT DESK  9/14/2017 DONE
DetailsBrian McGowan
Permit Ready to Issue  9/14/2017 DONE
All Met
Routing - PLANNING8/21/2017 9/14/2017 PASS
DetailsSue Cummings
Driveway not to exceed 33' wide within the front setback.
Routing PW Flood Plain9/7/2017 9/7/2017 PASS
DetailsJason C. Taylor
NOTE:
Two Elevation Certificates will be required; one prior to receiving a framing inspection, and one based upon finished construction. These certificates will need to be reviewed and approved by Public Works staff prior to occupancy approval. Jason Taylor ###-####
Routing PW Flood Plain8/25/2017 8/25/2017 FAIL
DetailsJason C. Taylor
See changemarks in ePlan. JCT
1st review completed  8/11/2017 FAIL
DetailsBrian McGowan
Engineering for tall walls and wall bracing required
Routing - PLAN CHECK6/26/2017 8/11/2017 FAIL
DetailsBrian McGowan
Engineering for tall walls and wall bracing required
Routing - PLANNING7/6/2017 7/6/2017 PASS
DetailsSue Cummings
Comply with PW for flood requirements
Route to Impact Fee Review6/26/20176/29/20177/4/2017 PASS
DetailsEric Bilimoria
Initial residential review of new SFD permits requested for now.
Routing PW Flood Plain6/26/2017 6/28/2017 FAIL
DetailsJason C. Taylor
A portion of the property is within the floodplain. Comply with Boise Floodplain Ordinance (B.C.C. 11-08). Elevation Certificate and elevations need to be placed on site plan, foundation plan, and cross section plans. Jason Taylor ###-####
Plans ACCEPTED BY PLAN TECH  6/26/2017 DONE
Intake Approval  6/26/2017 PASS
Recd Pcfee & Taken To Pln CK  6/26/2017 DONE
Routing - MECHANICAL6/26/2017 6/26/2017 PASS
DetailsTroy James
Routing - PLANNING6/26/2017 6/26/2017 FAIL
Needs floodplain review
Routing - Addressing6/26/2017 6/26/2017 LDH
DetailsLaura Hunter
Routing - PUBLIC WORKS6/26/2017 6/26/2017 PASS
DetailsRachael Beierle
Application received  6/19/2017 DONE