Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD17-02093
StatusFinaled
Name LANDMARK CONSTRUCTION MANAGEMENT LL
Site Address 6001 W RANDOLPH DR
Project NameThe Blake's House
Customer Number 
ePlanReviewYes
Description
Permit for home to be demolished and for construction of a new 3681 sq. ft., two story (first story 2447 sq. ft., second story 1234 sq. ft.) single family dwelling with 5 bedrooms, 4.5 bathrooms, approximately 600 sq. ft. of covered patio/porch and a 1412 sq. ft. attached garage per the approved plans. R-1C zoning and setbacks per planning. ***BJM***
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/9/20185/10/20185/10/2018APASS
DetailsMike Jordan
There is a lock box on the right side of the house attached to the gas meter. The code is 2056 Phone #: ###-#### Inspection requested via web by keith bucher
DOC - Permit Finaled5/10/20185/10/20185/10/2018PPASS
DetailsMike Jordan
All issues are resolved.
BLD-Final5/6/20185/7/20185/7/2018PCANC
DetailsMike Jordan
Lock box on right side of house attached to gas meter. Code is 2056 Phone #: ###-#### >> Inspection requested via web by keith bucher Inspection cancelled from web by: keith bucher
BLD-Final5/3/20185/4/20185/4/2018PCANC
DetailsMike Jordan
Lock box on side of house attached to gas meter. Code is 2056 Phone #: ###-#### >> Inspection requested via web by keith bucher Inspection cancelled from web by: keith bucher
BLD-Final5/3/20185/4/20185/3/2018ACANC
DetailsMike Jordan
Lock box on right side of house attached to gas meter. Code is 2056 Phone #: ###-#### >> Inspection requested via web by keith bucher Inspection cancelled from web by: keith bucher
BLD-Final4/30/20185/1/20185/1/2018AFAIL
DetailsMike Jordan
Key located in lock box on right side of house attached to gas meter. Code is 2056 Inspection requested via web by keith bucher. Provide code comp;iant handrail, cable guards at stairs require engineering. provide code compliant landings in back. Insulate crawl space. Step from bathroom to garage landing exceeds the 7.75 nch max. provide blower door test and required energy cert. Correction notice was posted.
BLD-Energy code compliance1/23/20181/24/20181/24/2018APASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by keith bucher
BLD-Framing/Rough-in1/24/20181/24/20181/24/2018APASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by keith bucher
BLD-Energy code compliance1/22/20181/23/20181/23/2018ANR
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by keith bucher. All fraing issues not yet corrected.
BLD-Energy code compliance1/22/20181/23/20181/22/2018PCANC
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by keith bucher Inspection cancelled from web by: keith bucher
BLD-Framing/Rough-in1/19/20181/22/20181/22/2018AFAIL
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by keith bucher. Complete lateral bracing and truss fix, install floor to floor straps. ok to insulate.
BLD-Framing/Rough-in1/18/20181/19/20181/19/2018PFAIL
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by keith bucher. Provide truss engineering, provide engineering for the lateral design. Complete all fireblocking on furdowns, Provide mech connection at all beam to column connections. Provide header over door wat on in terior bearing wall. Block all panel edges on shear walls. crawl space acess? Correction notice posted. not able to do complete framing or wall bracing inspection due to missing engineering.
Plan Modification Accepted  1/3/2018 DONE
new manual j report
Routing - MECHANICAL1/3/2018 1/3/2018 PASS
DetailsTroy James
resubmitted manual j report
BLD-Footing10/9/201710/10/201710/10/2017APART
DetailsMike Jordan
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo
Issue PAID IN FULL permit  9/29/2017 DONE
Inspection Record Card- Bld  9/29/2017 DONE
OVERRIDE  9/6/2017  
Permit Ready to Issue  9/6/2017 DONE
all met
Plan assigned to (BJM)6/28/20176/28/20179/1/2017 DONE
DetailsBrian McGowan
1st review complete - FAIL- 7/11 sfd ePlan Level 1
Routing - PLAN CHECK9/1/2017 9/1/2017 PASS
DetailsBrian McGowan
PLANS/APPL TAKEN TO FRONT DESK  9/1/2017 DONE
DetailsBrian McGowan
Routing - MECHANICAL8/14/2017 8/14/2017 PASS
DetailsTroy James
1st review completed  8/3/2017 FAIL
DetailsBrian McGowan
Structure issues
Routing - PLAN CHECK6/28/2017 8/3/2017 FAIL
DetailsBrian McGowan
Structure issues
Telephone call  8/2/2017 DONE
Keith Bucher emailed me, wanting to know when the permit would be ready-I spoke to Brian he'll try and have it done by Friday but the manual j's failed and we still have not received the corrections-i emailed Keith bqack with this info
Route to Impact Fee Review6/28/20177/1/20177/4/2017 PASS
DetailsEric Bilimoria
Initial residential review of new SFD permits requested for now.
Routing - MECHANICAL6/28/2017 6/30/2017 FAIL
DetailsTroy James
Routing - PLANNING6/28/2017 6/28/2017 PASS
DetailsSue Cummings
Max. driveway width in front setback is 33 ft. Small home occupation is allowed.
Routing - Addressing6/28/2017 6/28/2017 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS6/28/2017 6/28/2017 PASS
DetailsRachael Beierle
Plans ACCEPTED BY PLAN TECH  6/28/2017 DONE
Intake Approval  6/28/2017 PASS
Recd Pcfee & Taken To Pln CK  6/28/2017 DONE
Application received  6/26/2017 DONE
Application submitted via PDS Online on Jun 26 2017 12:18PM
Meeting  6/26/2017 DONE
waiting for customer to email me the building cross section-then i will approve the preescreen