Permit Information
Permit NumberBLD17-02291
StatusIssued
Name KING BUILDING & REMODELING
Site Address 497 E WARM SPRINGS AVE
Project NameWOODS-PURVIS RESIDENCE ADU
Customer NumberCAA17-00036 ADU APPROVAL
ePlanReviewYes
Description
DRH16-00412 - CAA17-00036 - Permit for a 591sq' ADU with 518sq' garage over 1,018sq' daylight basement workshop. Project includes a concrete plank garage floor, engineered concrete bond-beams, a carlift, canitlevered floor system, & windows. All work per plans, engineering & local code. Separate electrical, plumbing, & mechanical permits required. **JAB**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD - Resubmittal Approved8/30/20198/30/20198/30/2019PDEFR
DetailsBrandon Shaw
. Phone #: ###-#### Inspection requested via web by Jon King
BLD-Conference8/28/20198/29/20198/29/2019APEND
DetailsDave Hannah
Issue CN that permit will be expired if required inspections not requested left message to contact me priject is at sheetrock stage framing and insulate is all good jest need to finish and get finals
BLD-Energy code compliance6/28/20186/29/20186/29/2018PNR
DetailsDave Hannah
Dusty Phone #: ###-####
BLD-Framing/Rough-in6/26/20186/27/20186/27/2018PNR
DetailsDave Hannah
call when on way // Dusty Phone #: ###-#### needs air seal mec rough in and truss enginering
BLD-Wall Bracing6/26/20186/26/20186/26/2018PPASS
DetailsJim Storey
Please call ahead or access - Dusty Phone #: ###-#### engineering ok for garage// need to blk common wall for gyp
BLD-Wall Bracing1/3/20181/3/20181/3/2018PPEND
DetailsBrandon Shaw
Provide Engineering approval for "as built" wall bracing.
As per plans, SSW 24X10 brace panels (5) to be at garage door portal (2) and at south garage wall (3)
OK to cover exterior
BLD-Foundation9/27/20179/27/20179/28/2017PPASS
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Jon King
BLD-Footing9/8/20179/8/20179/11/2017PPASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Jon King
Issue PAID IN FULL permit  8/10/2017 DONE
OVERRIDE  8/8/2017  
Plan assigned to (JAB) Josh7/11/20177/11/20178/8/2017 PASS
DetailsJosh Bogle
1st. done - ADU, waiting on some construction details
Routing - PLAN CHECK8/8/2017 8/8/2017 PASS
DetailsJosh Bogle
PLANS/APPL TAKEN TO FRONT DESK  8/8/2017 DONE
DetailsJosh Bogle
ESC yes - Energy yes
Permit Ready to Issue  8/8/2017 DONE
Need GC and RP
1st review completed  7/20/2017 FAIL
DetailsJosh Bogle
Routing - PLAN CHECK7/11/2017 7/20/2017 FAIL
DetailsJosh Bogle
Routing - Design Review7/11/2017 7/18/2017 PASS
DetailsTed Vanegas
Route to Impact Fee Review7/11/20177/14/20177/14/2017 PASS
DetailsEric Bilimoria
Initial residential review of new SFD permits requested for now.
Routing - MECHANICAL7/11/2017 7/14/2017 PASS
DetailsTroy James
Geothermal heat
Routing - Addressing7/11/2017 7/12/2017 PASS
DetailsLaura Hunter
ADU address is 497 E Warm Springs Ave
Routing - PUBLIC WORKS7/11/2017 7/11/2017 PASS
DetailsRachael Beierle
Routing - PLANNING7/11/2017 7/11/2017 PASS
DetailsNicolette Womack
Plans ACCEPTED BY PLAN TECH  7/11/2017 DONE
Intake Approval  7/11/2017 PASS
Recd Pcfee & Taken To Pln CK  7/11/2017 DONE
Intake Approval  7/10/2017 FAIL
DetailsChristina Prado
PLans need to comply with submittal standards, emailed applicant from ePlan

Ryan,
You will need to re-upload your files following the naming and orientation requirements as detailed in this document. http://pds.cityofboise.org/media/105041/electronicstandards.pdf
Please re-upload your drawings in the required landscape format and rename them as specified. Let me know if you have any questions.
Thank you,
Christina ###-####
Application received  7/9/2017 DONE
Application submitted via PDS Online on Jul 9 2017 5:28PM
BLD-Conference8/30/20199/3/2019 A 
DetailsDave Hannah