Telephone call | | | 4/18/2018 | | DONE |
Christina Prado
|
|
|
Incorrect address assigned throughout review and completion. Correct address is 7590 W Victory Rd., not listed 7552 W Victory. All project addresses updated 4/18/18 by C_P and new CO issued
|
Permanent Occupancy UNPAID FEE | | | 4/18/2018 | | DONE |
|
|
|
|
Print Statement | | | 3/29/2018 | | DONE |
|
|
|
|
Third Notice | | 2/17/2018 | 3/14/2018 | | DONE |
|
|
|
mailed 3-15-18
|
Second Notice | | 1/21/2018 | 2/12/2018 | | DONE |
|
|
|
Mailed 2-13-18
|
First Notice | | 1/6/2018 | 1/11/2018 | | DONE |
|
|
|
Mailed 1-12-18
|
BLD-Final | 12/26/2017 | 12/27/2017 | 12/27/2017 | P | PASS |
Mike Jordan
|
|
|
Door glass installed. Phone #: ###-#### Inspection requested via web by Mark Steen. Ok for perm occ.
|
BLD-Final | 12/11/2017 | 12/12/2017 | 12/12/2017 | P | PART |
Mike Jordan
|
|
|
Troy to re-inspect doors and lights in the AM for fire life safety final, will pass the word whether we pass or fail. Thanks Phone #: ###-#### Inspection requested via web by Mark Steen. Ok for temp occ. nneds to install tempered glazing in doors and provide transition from offices.
|
FIRE-Final Inspection | 12/11/2017 | 12/12/2017 | 12/12/2017 | A | PASS |
Troy Cobbley
|
|
|
life safety passed
|
BLD-Final | 12/7/2017 | 12/8/2017 | 12/8/2017 | P | NR |
Jim Sly
|
|
|
Please note that a re-inspection for life safety was requested for AM. Also note that final electrical is scheduled for AM. Also refer to BLD17-00763 which is the same building and is also a PM Final. Allowing one visit on two Finals. Thanks, Mark Steen Phone #: ###-#### Inspection requested via web by Mark Steen Need fire final.......shell/core finaled.
|
FIRE-Final Inspection | 12/7/2017 | 12/8/2017 | 12/8/2017 | A | CANC |
Troy Cobbley
|
|
|
Not ready for final. Will be rescheduled for tuesday
Please note that a call to Carl Westfall about the door egress issue is awaiting a reply. Also The Exit Discharge lights will not be on the timer system any longer. Thanks, Mark Steen Phone #: ###-#### Inspection requested via web by Mark Steen
|
FIRE-Final Inspection | 12/6/2017 | 12/7/2017 | 12/7/2017 | P | FAIL |
Troy Cobbley
|
|
|
Provide correct hardware on all exit doors as discussed or provide plan review approval that they can be turned into windows by having hardware and exit signs removed. Exit discharge lights appear to be on a timer which is not allowed. provide missing exit sign at the north east exit door
|
BLD-Framing/Rough-in | 10/30/2017 | 10/31/2017 | 10/31/2017 | A | PASS |
Mike Jordan
|
|
|
Follow up, see notes from previous Insp of Oct 27. Thanks, Mark Steen Phone #: ###-#### Inspection requested via web by Kareen Falls. All trades have signed off.
|
BLD-Framing/Rough-in | 10/26/2017 | 10/27/2017 | 10/30/2017 | P | PART |
Brandon Shaw
|
|
|
OK to cover one side, pending other trades
|
Issue PAID IN FULL permit | | | 10/5/2017 | | DONE |
|
|
|
|
Print Occupancy Form | | | 10/5/2017 | | DONE |
|
|
|
|
Plan assigned to (CJW) | 8/9/2017 | 8/9/2017 | 10/2/2017 | | PASS |
Carl Westfall
|
|
|
(2nd done) (Aug 29 - 15 days) (22 sheets) Curtis Restaurant Equipment ePlan
|
Routing - PLAN CHECK | 9/29/2017 | | 10/2/2017 | | PASS |
Carl Westfall
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/2/2017 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 10/2/2017 | | DONE |
|
|
|
Met need
GC-MET
rev cert of val-MET
|
Route to Impact Fee Review | 9/15/2017 | 9/18/2017 | 9/29/2017 | | PASS |
Eric Bilimoria
|
|
|
Review requested for Commercial Permit
|
Plan resubmittals received | | | 9/29/2017 | | DONE |
|
|
|
|
Plan resubmittals received | | | 9/26/2017 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 9/26/2017 | | 9/26/2017 | | FAIL |
Carl Westfall
|
|
|
Need a new mechanical drawings that is compatible with the revised electrical drawing
|
Plan resubmittals requested | | | 9/26/2017 | | DONE |
|
|
|
|
1st review completed | | | 9/15/2017 | | DONE |
|
|
|
|
Plan resubmittals requested | | | 9/15/2017 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 8/9/2017 | | 9/15/2017 | | FAIL |
Carl Westfall
|
|
|
Revised drawings required
|
Routing - FIRE | 8/9/2017 | 8/9/2017 | 8/21/2017 | | PASS |
Scott Arellano
|
|
|
Attached comments to plans.
|
Routing PW Environmental | 8/9/2017 | | 8/15/2017 | | PASS |
Rick Christenson
|
|
|
|
Routing - MECHANICAL | 8/9/2017 | | 8/10/2017 | | PASS |
Troy James
|
|
|
No work allowed under this permit at test kitchen. Separate permit required.
|
Routing - PLUMBING | 8/9/2017 | | 8/9/2017 | | PASS |
Daryl Spivey
|
|
|
Per plan and ISPC.
|
Routing - Addressing | 8/9/2017 | | 8/9/2017 | | PASS |
Doug Chausow
|
|
|
Updated address: 7590 W Victory Rd
|
Routing - PUBLIC WORKS | 8/9/2017 | | 8/9/2017 | | PASS |
Rachael Beierle
|
|
|
|
Routing - Design Review | 8/9/2017 | | 8/9/2017 | | PASS |
Katelyn Menuge
|
|
|
CZC17-00204
|
Routing - PLANNING | 8/9/2017 | | 8/9/2017 | | PASS |
Katelyn Menuge
|
|
|
|
Intake Approval | | | 8/9/2017 | | PASS |
Javier Guzman
|
|
|
|
Plan Reviewer's activity | | | 8/8/2017 | | DONE |
Julie Romig
|
|
|
This is a new building with a first time tenant build out, route as a 520 Major TI. Contacted architect 8/8/17 and let them know.
|
Application received | | | 7/19/2017 | | DONE |
|
|
|
Application submitted via PDS Online on Jul 19 2017 9:41AM
|